Bin Qu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bin Qu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Albert H. Titus
Departments of Electrical Engineering and Biomedical Engineering, University at Buffalo, Buffalo NY 14260 USA
3 shared publications - Alexander N. Cartwright
Departments of Electrical Engineering and Biomedical Engineering, University at Buffalo, Buffalo NY 14260 USA
3 shared publications - Daniel R. Bednarek
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Stephen Rudin
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
3 shared publications - Weiyuan Wang
Departments of Physiology and Biophysics, University at Buffalo, Buffalo NY 14214 USA
3 shared publications - Ying Huang
Department of Electrical Engineering, University at Buffalo, Buffalo, NY 14260 USA
3 shared publications
Latest Publications
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 2634-2637
Image geometric corrections for a new EMCCD-based dual modular x-ray imager
An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2×1 array design efficiently increased the clinical field of view, and also can be readily expanded to an MxN array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048×1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 2634-2637
Image geometric corrections for a new EMCCD-based dual modular x-ray imager
An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2×1 array design efficiently increased the clinical field of view, and also can be readily expanded to an MxN array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048×1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2607-2609
Optical demonstration of a medical imaging system with an EMCCD-sensor array for use in a high resolution dynamic X-ray imager
Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2607-2609
Optical demonstration of a medical imaging system with an EMCCD-sensor array for use in a high resolution dynamic X-ray imager
Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 3438-3441
Quantum performance analysis of an EMCCD-based x-ray detector using photon transfer technique
The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detector's field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 e - /DN at unit gain, with a read noise of 71.5±6.0 e - rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 ke - , providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 3438-3441
Quantum performance analysis of an EMCCD-based x-ray detector using photon transfer technique
The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detector's field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 e - /DN at unit gain, with a read noise of 71.5±6.0 e - rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 ke - , providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected.