Fumihiro Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fumihiro Saito has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jun Koarashi
Japan Atomic Energy Agency
2 shared publications Eunjoo Kim
Research Center for Radiation Emergency Medicine , National Institute of Radiological Sciences , Inage-ku, Chiba-city, Chiba 263-8555 , Japan
1 shared publication- Eunjoo Kim
National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-city, Chiba, Japan
1 shared publication Kunio Shiraishi
Research Center for Radiation Emergency Medicine , National Institute of Radiological Sciences, Inage-ku, Chiba-city, Chiba 263-8555 , Japan
1 shared publicationMakoto Akashi
Research Center for Radiation Emergency Medicine , National Institute of Radiological Sciences, Inage-ku, Chiba-city, Chiba 263-8555 , Japan
1 shared publicationOsamu Kurihara
Radiation Protection Department, Nuclear Fuel Cycle Engineering Laboratories , Tokai Research and Development Center , Japan Atomic Energy Agency , Tokai-mura, Ibaraki 319-1194 , Japan 3 Research Center for Radiation Emergency Medicine , National Institute of Radiological Sciences , Inage-ku, Chiba-city, Chiba 263-8555 , Japan
1 shared publication
Latest Publications
- 18 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 145 (1) , 13-20
Emission rates of alpha particles from supports with different surface conditions in direct deposition sources
Direct deposition is the only method that can be utilised for the standardisation of radioactive solutions because there is no deposition loss on a support. The present study investigated how much the roughness of the support influences the emission rate of alpha particles for direct deposition sources from the practical viewpoint of use of the method. A number of samples were prepared by evaporating a 0.1-ml aliquot of a dilute nitric acid aqueous solution that contained 241Am on stainless steel supports with four different surface conditions; untreated supports were either polished (using metal abrasives available commercially) or not polished, and buffed supports (grid size of #400) were either polished or not polished. Alpha spectrometry of the samples revealed that the detection efficiency was significantly different between the non-polished and polished supports; the former was lower by 3 % than the latter for both the untreated and buffed supports. Microscopic observations clarified that the counting loss was attributed to irregular flaws or polishing lines on the non-polished supports, most of which were found to be in the order of submicron in depth and were diminished on the polished supports. One may usually assume that a direct deposition source offers no counting loss if its entire energy spectrum is seen above a low-energy discrimination limit of the spectrometer. However, this should be experimentally confirmed using a solution with known activity. It was difficult to identify the counting loss for the buffed supports without polishing because their energy spectra showed little degradation.
- 18 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 145 (1) , 13-20
Emission rates of alpha particles from supports with different surface conditions in direct deposition sources
Direct deposition is the only method that can be utilised for the standardisation of radioactive solutions because there is no deposition loss on a support. The present study investigated how much the roughness of the support influences the emission rate of alpha particles for direct deposition sources from the practical viewpoint of use of the method. A number of samples were prepared by evaporating a 0.1-ml aliquot of a dilute nitric acid aqueous solution that contained 241Am on stainless steel supports with four different surface conditions; untreated supports were either polished (using metal abrasives available commercially) or not polished, and buffed supports (grid size of #400) were either polished or not polished. Alpha spectrometry of the samples revealed that the detection efficiency was significantly different between the non-polished and polished supports; the former was lower by 3 % than the latter for both the untreated and buffed supports. Microscopic observations clarified that the counting loss was attributed to irregular flaws or polishing lines on the non-polished supports, most of which were found to be in the order of submicron in depth and were diminished on the polished supports. One may usually assume that a direct deposition source offers no counting loss if its entire energy spectrum is seen above a low-energy discrimination limit of the spectrometer. However, this should be experimentally confirmed using a solution with known activity. It was difficult to identify the counting loss for the buffed supports without polishing because their energy spectra showed little degradation.
- Open Access
- 18 January 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (4) , 584-589
An imaging plate technique for evaluating energy attenuation in evaporated samples with different surface conditions
In this paper, a new technique was proposed using an imaging plate (IP) as a useful tool for visually and quantitatively evaluating the attenuation of radiation energy on radiation sources. Samples were prepared by evaporating 241Am solution on stainless steel disks with well-polished and non-polished surfaces. The samples were measured with an IP and then the obtained images were analysed based on two-dimensional photostimulated luminescence data. The images for the polished disks generally showed lower uniformity in the distribution than those for the non-polished disks. However, the detailed analysis of the images revealed a poor correlation between the source distribution and the attenuation of radiation energy for the disk samples, indicating that the non-uniformity of distribution was not a primary cause of the attenuation of radiation energy for the samples. The demonstration in this study showed a potential usefulness of the IP-based technique for evaluating self-absorption mechanisms, although the technique remains to be critically tested particularly using disk samples made by different preparation methods.
- 18 January 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (4) , 584-589
Open AccessAn imaging plate technique for evaluating energy attenuation in evaporated samples with different surface conditions
In this paper, a new technique was proposed using an imaging plate (IP) as a useful tool for visually and quantitatively evaluating the attenuation of radiation energy on radiation sources. Samples were prepared by evaporating 241Am solution on stainless steel disks with well-polished and non-polished surfaces. The samples were measured with an IP and then the obtained images were analysed based on two-dimensional photostimulated luminescence data. The images for the polished disks generally showed lower uniformity in the distribution than those for the non-polished disks. However, the detailed analysis of the images revealed a poor correlation between the source distribution and the attenuation of radiation energy for the disk samples, indicating that the non-uniformity of distribution was not a primary cause of the attenuation of radiation energy for the samples. The demonstration in this study showed a potential usefulness of the IP-based technique for evaluating self-absorption mechanisms, although the technique remains to be critically tested particularly using disk samples made by different preparation methods.