Reinaldo Calixto de Campos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Reinaldo Calixto de Campos has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Aderval Severino Luna
PhD in Chemistry Institution Universidade do Estado do Rio de Janeiro Rio de Janeiro Rio de Janeiro Brazil
4 shared publications - Geisamanda Pedrini Brandão
Department of Chemistry, Federal University of Espírito Santo, 29075-910, Vitória, ES, Brazil
2 shared publications Iracema Takase
Department of Analytical Chemistry, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
2 shared publicationsMariela N. Matos Reyes
Department of Chemistry, Pontifícia Universidade Católica do Rio de Janeiro, Rua Marques de São Vicente 225, 22453-900 Rio de Janeiro, RJ, Brazil
2 shared publications- Patricia Grinberg
Metrology Research Centre, National Research Council Canada, Ottawa, Canada
2 shared publications Aderval S. Luna
Universidade do Estado do Rio de Janeiro, Rio de Janeiro
1 shared publication
Latest Publications
- 24 October 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 386 (7-8) , 2249-2253
Direct determination of nickel in petroleum by solid sampling–graphite furnace atomic absorption spectrometry
A procedure for the direct GFAAS determination of Ni in petroleum samples using a solid sampling strategy is proposed. Palladium was used as conventional modifier. Central composite design multivariate optimization defined the optimum temperature program and the Pd mass, allowing calibration using aqueous analytical solution. The limit of detection (LOD) at the optimized conditions was 0.23 ng of Ni, for typical sample masses between of 0.10 and 0.60 mg. Linearity at least up to 11 ng of Ni and a characteristic mass of 45 pg were observed, defining a dynamic range between 0.52 and 110 μg g−1. Typical coefficients of variation (n = 10) in the analysis of oil reference materials were 7%. Method validation was performed both by the analysis of oil certified reference materials and by comparison with an independent method (ASTM 5863-B). No statistically significant difference was observed between obtained and expected values. The total determination cycle lasted 5 min, equivalent to a sample throughput of 6 h−1 for duplicate determinations.
- 24 October 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 386 (7-8) , 2249-2253
Direct determination of nickel in petroleum by solid sampling–graphite furnace atomic absorption spectrometry
A procedure for the direct GFAAS determination of Ni in petroleum samples using a solid sampling strategy is proposed. Palladium was used as conventional modifier. Central composite design multivariate optimization defined the optimum temperature program and the Pd mass, allowing calibration using aqueous analytical solution. The limit of detection (LOD) at the optimized conditions was 0.23 ng of Ni, for typical sample masses between of 0.10 and 0.60 mg. Linearity at least up to 11 ng of Ni and a characteristic mass of 45 pg were observed, defining a dynamic range between 0.52 and 110 μg g−1. Typical coefficients of variation (n = 10) in the analysis of oil reference materials were 7%. Method validation was performed both by the analysis of oil certified reference materials and by comparison with an independent method (ASTM 5863-B). No statistically significant difference was observed between obtained and expected values. The total determination cycle lasted 5 min, equivalent to a sample throughput of 6 h−1 for duplicate determinations.
- 25 July 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 385 (8) , 1562-1569
Determination of arsenic in diesel, gasoline and naphtha by graphite furnace atomic absorption spectrometry using microemulsion medium for sample stabilization
A procedure for the determination of As in diesel, gasoline and naphtha at μg L−1 levels by GFAAS is proposed. Sample stabilization was achieved by the formation of three component solutions prepared by mixing appropriate volumes of the samples propan-1-ol and nitric acid aqueous solution. This mixture resulted in a one-phase medium, which was indefinitely stable. No changes in the analyte signals were observed over several days in spiked samples, proving long-term stabilization ability. The use of conventional (Pd) and permanent (Ir) modification was investigated and the former was preferred. Central composite design multivariate optimization defined the optimum microemulsion composition as well as the temperature program. In this way, calibration using aqueous analytical solutions was possible, since the same sensitivity was observed in the investigated microemulsion media and in 0.2% v/v HNO3. Coefficients of correlation larger than 0.999 and an As characteristic mass of 22 pg were observed. Recoveries (n=4) obtained from spiked samples were 98±4, 99±3 and 103±5%, and the limits of detection in the original samples were 1.8, 1.2 and 1.5 μg L−1 for diesel, gasoline and naphtha, respectively. Validation was performed by the analysis of a set of commercial samples by independent comparative procedures. No significant difference (Student’s t-test, p−1 for diesel and 10 h−1 for gasoline and naphtha.
- 25 July 2006
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 385 (8) , 1562-1569
Determination of arsenic in diesel, gasoline and naphtha by graphite furnace atomic absorption spectrometry using microemulsion medium for sample stabilization
A procedure for the determination of As in diesel, gasoline and naphtha at μg L−1 levels by GFAAS is proposed. Sample stabilization was achieved by the formation of three component solutions prepared by mixing appropriate volumes of the samples propan-1-ol and nitric acid aqueous solution. This mixture resulted in a one-phase medium, which was indefinitely stable. No changes in the analyte signals were observed over several days in spiked samples, proving long-term stabilization ability. The use of conventional (Pd) and permanent (Ir) modification was investigated and the former was preferred. Central composite design multivariate optimization defined the optimum microemulsion composition as well as the temperature program. In this way, calibration using aqueous analytical solutions was possible, since the same sensitivity was observed in the investigated microemulsion media and in 0.2% v/v HNO3. Coefficients of correlation larger than 0.999 and an As characteristic mass of 22 pg were observed. Recoveries (n=4) obtained from spiked samples were 98±4, 99±3 and 103±5%, and the limits of detection in the original samples were 1.8, 1.2 and 1.5 μg L−1 for diesel, gasoline and naphtha, respectively. Validation was performed by the analysis of a set of commercial samples by independent comparative procedures. No significant difference (Student’s t-test, p−1 for diesel and 10 h−1 for gasoline and naphtha.
- Open Access
- 1 February 2006
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 17 (1) , 156-161
Scanner image analysis in the quantification of mercury using spot-tests
A digital image analysis procedure for mercury quantification based on the analysis of the color developed in a spot-test derived reaction using a commercial scanner is described. The color intensity is related to the concentration in the original sample. Digital image analysis of the developed color was used to establish a quantitative relationship between the color components and the mercury concentration. Different color separation models were compared and their sensitivity to the variation of the mercury concentration was evaluated. The Hue-Lightness-Saturation (HLS) model provided the best results, showing a linear relationship between the Hue value and the mercury concentration. The procedure was used for the analysis of interlaboratorial fish samples and good concordance between found and reported values was found. The detection limits were estimated from the confidence bands of the analytical curves. For a calibration interval of 100 to 600 ng, a detection limit of 0.007 µg g-1 (wet weight) was found.
- 1 February 2006
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 17 (1) , 156-161
Open AccessScanner image analysis in the quantification of mercury using spot-tests
A digital image analysis procedure for mercury quantification based on the analysis of the color developed in a spot-test derived reaction using a commercial scanner is described. The color intensity is related to the concentration in the original sample. Digital image analysis of the developed color was used to establish a quantitative relationship between the color components and the mercury concentration. Different color separation models were compared and their sensitivity to the variation of the mercury concentration was evaluated. The Hue-Lightness-Saturation (HLS) model provided the best results, showing a linear relationship between the Hue value and the mercury concentration. The procedure was used for the analysis of interlaboratorial fish samples and good concordance between found and reported values was found. The detection limits were estimated from the confidence bands of the analytical curves. For a calibration interval of 100 to 600 ng, a detection limit of 0.007 µg g-1 (wet weight) was found.
- 3 November 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (7-8) , 1044-1051
The determination of total Se in urine and serum by graphite furnace atomic absorption spectrometry using Ir as permanent modifier and in situ oxidation for complete trimethylselenonium recovery
- 3 November 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (7-8) , 1044-1051
The determination of total Se in urine and serum by graphite furnace atomic absorption spectrometry using Ir as permanent modifier and in situ oxidation for complete trimethylselenonium recovery
- 15 September 2005
- Published by Elsevier in Science of The Total Environment
- Vol. 348 (1-3) , 128-134
Mercury contamination in farmed fish setup on former garimpo mining areas in the Northern Mato Grosso State, Amazonian region, Brazil
- 15 September 2005
- Published by Elsevier in Science of The Total Environment
- Vol. 348 (1-3) , 128-134
Mercury contamination in farmed fish setup on former garimpo mining areas in the Northern Mato Grosso State, Amazonian region, Brazil
- Open Access
- 1 August 2004
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 15 (4) , 487-490
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.
- 1 August 2004
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 15 (4) , 487-490
Open AccessDetermination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.
- 10 December 2002
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 57 (12) , 2103-2112
Sequential quantification of methyl mercury in biological materials by selective reduction in the presence of mercury(II), using two gas–liquid separators
- 10 December 2002
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 57 (12) , 2103-2112
Sequential quantification of methyl mercury in biological materials by selective reduction in the presence of mercury(II), using two gas–liquid separators