D. Capatina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
D. Capatina has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- C. Doose
Argonne National Laboratory, Argonne, IL, USA
1 shared publication D. Skiadopoulos
Argonne National Laboratory, Argonne, IL, USA
1 shared publicationE. M. Trakhtenberg
Argonne National Laboratory, Argonne, IL, USA
1 shared publication- E. R. Moog
Argonne National Laboratory, Argonne, IL, USA
1 shared publication E. Trakhtenberg
Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439, USA
1 shared publicationH. Nojiri
Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
1 shared publication
Latest Publications
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 030036
DCS - A high flux beamline for time resolved dynamic compression science – Design highlights
The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm2. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1741 (1) , 030036
DCS - A high flux beamline for time resolved dynamic compression science – Design highlights
The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm2. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.
- 22 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1717-1720
A Design Concept for a Planar Superconducting Undulator for the APS
A superconducting planar undulator is under development at the Advanced Photon Source. The R&D phase culminated in the successful testing of several short magnetic structure prototypes. Work is now focused on a complete design for the first undulator. The conceptual designs for its superconducting magnet, the cooling system, and the cryostat are described in this paper.
- 22 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1717-1720
A Design Concept for a Planar Superconducting Undulator for the APS
A superconducting planar undulator is under development at the Advanced Photon Source. The R&D phase culminated in the successful testing of several short magnetic structure prototypes. Work is now focused on a complete design for the first undulator. The conceptual designs for its superconducting magnet, the cooling system, and the cryostat are described in this paper.
- 1 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical design of a dual-cryostat instrument for a high-field pulsed magnet
The engineering of a dual-cryostat for a pulsed-magnet instrument at the Advanced Photon Source is presented. The dual-cryostat independently cools the magnet coil (using liquid-nitrogen) and the sample (using a closed-cycle refrigerator). Liquid-nitrogen cooling may allow a repetition rate of a few minutes for peak fields near 30 T. The system is unique in that the liquid-nitrogen cryostat incorporates a double-funnel vacuum tube passing through the solenoid's bore in order to preserve the entire angular range allowed by the magnet bore for scattering studies. Second, the use of a separate refrigerator for the sample allows precise positioning of samples in the bore while minimizing magnet vibrations propagating to the sample during pulsed-field generation.
- 1 October 2010
- Published by Cambridge University Press (CUP) in Diamond Light Source Proceedings
- Vol. 1 (MEDSI-6)
Mechanical design of a dual-cryostat instrument for a high-field pulsed magnet
The engineering of a dual-cryostat for a pulsed-magnet instrument at the Advanced Photon Source is presented. The dual-cryostat independently cools the magnet coil (using liquid-nitrogen) and the sample (using a closed-cycle refrigerator). Liquid-nitrogen cooling may allow a repetition rate of a few minutes for peak fields near 30 T. The system is unique in that the liquid-nitrogen cryostat incorporates a double-funnel vacuum tube passing through the solenoid's bore in order to preserve the entire angular range allowed by the magnet bore for scattering studies. Second, the use of a separate refrigerator for the sample allows precise positioning of samples in the bore while minimizing magnet vibrations propagating to the sample during pulsed-field generation.