RKRichard Kramer

Richard Kramer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard Kramer has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A new parallel-plate graphite ionization chamber as a 60Co gamma radiation reference instrument

    by Ana P. Perini, Lucio P. Neves, José M. Fernández-Varea, Vagner F. Cassola, Richard Kramer, Helen J. Khoury, Linda V.E. Caldas


  • Dosimetric application of a special pencil ionization chamber in radiotherapy X-ray beams

    by Lucio P. Neves, Ana P. Perini, José M. Fernández-Varea, Vagner F. Cassola, Richard Kramer, Helen J. Khoury, Linda V.E. Caldas


  • Development of newborn and 1-year-old reference phantoms based on polygon mesh surfaces

    by V F Cassola, R Kramer, V J de Melo Lima, C A B de Oliveira Lira, H J Khoury, J W Vieira, K Robson Brown

    The purpose of this study is the development of paediatric reference phantoms for newborn and 1-year-old infants to be used for the calculation of organ and tissue equivalent doses in radiation protection. The study proposes a method for developing anatomically highly sophisticated paediatric phantoms without using medical images. The newborn and 1-year-old hermaphrodite phantoms presented here were developed using three-dimensional (3D) modelling software applied to anatomical information taken from atlases, textbooks and images provided by the Department of Anatomy of the Federal University of Pernambuco, Brazil. The method uses polygon mesh surfaces to model body contours, the shape of organs as well as their positions and orientations in the human body. Organ and tissue masses agree with corresponding data given by the International Commission on Radiological Protection for newborn and 1-year-old reference children. Bones were segmented into cortical bone, spongiosa, medullary marrow and cartilage to allow for the use of μCT images of trabecular bone for skeletal dosimetry. Anatomical results show 3D images of the phantoms' surfaces, organs and skeletons, as well as tables with organ and tissue masses or skeletal tissue volumes. Dosimetric results present comparisons of organ and tissue absorbed doses or specific absorbed fractions between the newborn and 1-year-old phantoms and corresponding data for other paediatric stylised or voxel phantoms. Most differences were found to be below 10%.


  • Skeletal dosimetry based on µCT images of trabecular bone: update and comparisons

    by R Kramer, V F Cassola, J W Vieira, H J Khoury, C A B de Oliveira Lira, K Robson Brown

    Two skeletal dosimetry methods using µCT images of human bone have recently been developed: the paired-image radiation transport (PIRT) model introduced by researchers at the University of Florida (UF) in the US and the systematic–periodic cluster (SPC) method developed by researchers at the Federal University of Pernambuco in Brazil. Both methods use µCT images of trabecular bone (TB) to model spongiosa regions of human bones containing marrow cavities segmented into soft tissue volumes of active marrow (AM), trabecular inactive marrow and the bone endosteum (BE), which is a 50 µm thick layer of marrow on all TB surfaces and on cortical bone surfaces next to TB as well as inside the medullary cavities. With respect to the radiation absorbed dose, the AM and the BE are sensitive soft tissues for the induction of leukaemia and bone cancer, respectively. The two methods differ mainly with respect to the number of bone sites and the size of the µCT images used in Monte Carlo calculations and they apply different methods to simulate exposure from radiation sources located outside the skeleton. The PIRT method calculates dosimetric quantities in isolated human bones while the SPC method uses human bones embedded in the body of a phantom which contains all relevant organs and soft tissues. Consequently, the SPC method calculates absorbed dose to the AM and to the BE from particles emitted by radionuclides concentrated in organs or from radiation sources located outside the human body in one calculation step. In order to allow for similar calculations of AM and BE absorbed doses using the PIRT method, the so-called dose response functions (DRFs) have been developed based on absorbed fractions (AFs) of energy for electrons isotropically emitted in skeletal tissues. The DRFs can be used to transform the photon fluence in homogeneous spongiosa regions into absorbed dose to AM and BE. This paper will compare AM and BE AFs of energy from electrons emitted in skeletal tissues calculated with the SPC and the PIRT method and AM and BE absorbed doses and AFs calculated with PIRT-based DRFs and with the SPC method. The results calculated with the two skeletal dosimetry methods agree well if one takes the differences between the two models properly into account. Additionally, the SPC method will be updated with larger µCT images of TB.


  • Electron absorbed fractions of energy andS-values in an adult human skeleton based on µCT images of trabecular bone

    by R Kramer, R B Richardson, V F Cassola, J W Vieira, H J Khoury, C A B de O Lira, K Robson Brown

    When the human body is exposed to ionizing radiation, among the soft tissues at risk are the active marrow (AM) and the bone endosteum (BE) located in tiny, irregular cavities of trabecular bone. Determination of absorbed fractions (AFs) of energy or absorbed dose in the AM and the BE represent one of the major challenges of dosimetry. Recently, at the Department of Nuclear Energy at the Federal University of Pernambuco, a skeletal dosimetry method based on µCT images of trabecular bone introduced into the spongiosa voxels of human phantoms has been developed and applied mainly to external exposure to photons. This study uses the same method to calculate AFs of energy and S-values (absorbed dose per unit activity) for electron-emitting radionuclides known to concentrate in skeletal tissues. The modelling of the skeletal tissue regions follows ICRP110, which defines the BE as a 50 µm thick sub-region of marrow next to the bone surfaces. The paper presents mono-energetic AFs for the AM and the BE for eight different skeletal regions for electron source energies between 1 keV and 10 MeV. The S-values are given for the beta emitters (14)C, (59)Fe, (131)I, (89)Sr, (32)P and (90)Y. Comparisons with results from other investigations showed good agreement provided that differences between methodologies and trabecular bone volume fractions were properly taken into account. Additionally, a comparison was made between specific AFs of energy in the BE calculated for the actual 50 µm endosteum and the previously recommended 10 µm endosteum. The increase in endosteum thickness leads to a decrease of the endosteum absorbed dose by up to 3.7 fold when bone is the source region, while absorbed dose increases by ∼20% when the beta emitters are in marrow.


  • FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations

    by R Kramer, V F Cassola, H J Khoury, J W Vieira, V J de Melo Lima, K Robson Brown

    Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been developed in the first part of this study using 3D animation software and anatomical atlases to replace the image-based FAX06 and the MAX06 voxel phantoms. 3D modelling methods allow for phantom development independent from medical images of patients, volunteers or cadavers. The second part of this study investigates the dosimetric implications for organ and tissue equivalent doses due to the anatomical differences between the new and the old phantoms. These differences are mainly caused by the supine position of human bodies during scanning in order to acquire digital images for voxel phantom development. Compared to an upright standing person, in image-based voxel phantoms organs are often coronally shifted towards the head and sometimes the sagittal diameter of the trunk is reduced by a gravitational change of the fat distribution. In addition, volumes of adipose and muscle tissue shielding internal organs are sometimes too small, because adaptation of organ volumes to ICRP-based organ masses often occurs at the expense of general soft tissues, such as adipose, muscle or unspecified soft tissue. These effects have dosimetric consequences, especially for partial body exposure, such as in x-ray diagnosis, but also for whole body external exposure and for internal exposure. Using the EGSnrc Monte Carlo code, internal and external exposure to photons and electrons has been simulated with both pairs of phantoms. The results show differences between organ and tissue equivalent doses for the upright standing FASH/MASH and the image-based supine FAX06/MAX06 phantoms of up to 80% for external exposure and up to 100% for internal exposure. Similar differences were found for external exposure between FASH/MASH and REGINA/REX, the reference voxel phantoms of the International Commission on Radiological Protection. Comparison of effective doses for external photon exposure showed good agreement between FASH/MASH and REGINA/REX, but large differences between FASH/MASH and the mesh-based RPI_AM and the RPI_AF phantoms, developed at the Rensselaer Polytechnic Institute (RPI).


  • Skeletal dosimetry for external exposures to photons based on images of spongiosa: Consideration of voxel resolution, cluster size, and medullary bone surfaces

    by R. Kramer, H. J. Khoury, J. W. Vieira, K. A. Robson Brown

    Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skeletons were replaced at run time by so-called micromatrices, which have exactly the size of a spongiosa voxel and contain segmented trabecular bone and marrow micro-voxels. A cluster (=parallelepiped) of 2 x 2 x 2 = 8 micromatrices was used systematically and periodically throughout the spongiosa volume during the radiation transport calculation. Systematic means that when a particle leaves a spongiosa voxel to enter into a neighboring spongiosa voxel, then the next micromatrix in the cluster will be used. Periodical means that if the particle travels through more than two spongiosa voxels in a row, then the cluster will be repeated. Based on the bone samples available at the time, clusters of up to 3 x 3 x 3 = 27 micromatrices were studied. While for a given trabecular bone volume fraction the whole-body RBM equivalent dose showed converging results for cluster sizes between 8 and 27 micromatrices, this was not the case for the BSC equivalent dose. The BSC equivalent dose seemed to be very sensitive to the number, form, and thickness of the trabeculae. In addition, the cluster size and/or the microvoxel resolution were considered to be possible causes for the differences observed. In order to resolve this problem, this study used a bone sample large enough to extract clusters containing up to 8 x 8 x 8 = 512 micro-matrices and which was scanned with two different voxel resolutions. Taking into account a recent proposal, this investigation also calculated the BSC equivalent dose on medullary surfaces of cortical bone in the arm and leg bones. The results showed (1) that different voxel resolutions have no effect on the RBM equivalent dose but do influence the BSC equivalent dose due to voxel effects by up to 5% for incident photon energies up to 200 keV, (2) that the whole-body BSC equivalent dose calculated with a cluster with 2 x 2 x 2 = 8 micromatrices is consistent with results received with clusters of up to 8 x 8 x 8 = 512 micromatrices, and (3) that for external whole-body exposure the inclusion of the BSC on medullary surfaces of cortical bone has a negligible effect on the whole-body BSC equivalent dose.


  • CALDose_X—a software tool for the assessment of organ and tissue absorbed doses, effective dose and cancer risks in diagnostic radiology

    by R Kramer, H J Khoury, J W Vieira

    CALDose_X is a software tool that provides the possibility of calculating incident air kerma (INAK) and entrance surface air kerma (ESAK), two important quantities used in x-ray diagnosis, based on the output of the x-ray equipment. Additionally, the software uses conversion coefficients (CCs) to assess the absorbed dose to organs and tissues of the human body, the effective dose as well as the patient's cancer risk for radiographic examinations. The CCs, ratios between organ or tissue absorbed doses and measurable quantities, have been calculated with the FAX06 and the MAX06 phantoms for 34 projections of 10 commonly performed x-ray examinations, for 40 combinations of tube potential and filtration ranging from 50 to 120 kVcp and from 2.0 to 5.0 mm aluminum, respectively, for various field positions, for 29 selected organs and tissues and simultaneously for the measurable quantities, INAK, ESAK and kerma area product (KAP). Based on the x-ray irradiation parameters defined by the user, CALDose_X shows images of the phantom together with the position of the x-ray beam. By using true to nature voxel phantoms, CALDose_X improves earlier software tools, which were mostly based on mathematical MIRD5-type phantoms, by using a less representative human anatomy.


  • Skeletal dosimetry for external exposure to photons based on µCT images of spongiosa from different bone sites

    by R Kramer, H J Khoury, J W Vieira, I Kawrakow

    Micro computed tomography (mu CT) images of human spongiosa have recently been used for skeletal dosimetry with respect to external exposure to photon radiation. In this previous investigation, the calculation of equivalent dose to the red bone marrow (RBM) and to the bone surface cells (BSC) was based on five different clusters of micro matrices derived from mu CT images of vertebrae, and the BSC equivalent dose for 10 mu m thickness of the BSC layer was determined using an extrapolation method. The purpose of this study is to extend the earlier investigation by using mu CT images from eight different bone sites and by introducing an algorithm for the direct calculation of the BSC equivalent dose with sub-micro voxel resolution. The results show that for given trabecular bone volume fractions (TBVFs) the whole-body RBM equivalent dose does not depend on bone site-specific properties or imaging parameters. However, this study demonstrates that apart from the TBVF and the BSC layer thickness, the BSC equivalent dose additionally depends on a so-called trabecular bone structure (TBS) effect, i.e. that the contribution of photo-electrons released in trabecular bone to the BSC equivalent dose also depends on the bone site-specific structure of the trabeculae. For a given bone site, the TBS effect is also a function of the thickness of the BSC layer, and it could be shown that this effect would disappear almost completely, should the BSC layer thickness be raised from 10 to 50 mu m, according to new radiobiological findings.