Fernando Roberto de Andrade Lima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fernando Roberto de Andrade Lima has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Carlos Alberto Brayner de Oliveira Lira
5 shared publicationsJ W Vieira
5 shared publicationsH J Khoury
4 shared publications- Richard Kramer
Univ Fed Pernambuco, Dept Energia Nucl, BR-50740540 Recife, PE, Brazil
4 shared publications Jair de Lima Bezerra
3 shared publications- José Wilson Vieira
Federal Education Science and Technology Institute of Pernambuco
3 shared publications
Latest Publications
- Open Access
- 4 February 2025
- Published by Brazilian Society for Computational and Applied Mathematics (SBMAC) in Trends in Computational and Applied Mathematics
- Vol. 26 (1)
Um Novo Modelo Computacional De Exposição Para Simular A Radioembolização Usando O Ítrio 90m Novo Modelo Computacional De Exposição Para Simular A Radioembolização Usando O Ítrio 90
Para avaliar a energia depositada em órgãos e tecidos radiossensíveis do corpo humano é preciso desenvolver modelos computacionais de exposição (MCEs). Um MCE é composto por um fantoma (neologismo da palavra inglesa phantom) antropomórfico em posição matematicamente definida em relação a uma fonte radioativa. A fonte é um algoritmo destinado a produzir o estado inicial da simulação, isto é, o modo como o fantoma começa a ser irradiado. Usando técnicas Monte Carlo (MC) implementadas em robustos códigos disponíveis na comunidade científica, são simuladas as histórias das partículas, de interação em interação, até que suas energias estejam abaixo de um limiar de corte ou elas saiam do fantoma. Este trabalho apresenta um novo MCE chamado MSUPREE onde o fantoma é o MASHSup (Male Adult meSH in a Supine position), desenvolvido no DEN-UFPE, e o código MC é o EGSnrc (EGS = Electron Gamma Shower; nrc = National Research Council Canada). O algoritmo implementado da fonte consiste em um método não paramétrico desenvolvido pelos autores para gerar amostras de elétrons oriundos do decaimento do radionuclídeo ítrio 90 (Y-90), usado em radioembolização, um tratamento de tumores hepáticos. O estado inicial de um elétron é definido, principalmente, pela posição de largada, a direção de voo e a energia inicial. No MSUPREE os sorteios das posições iniciais ocorrem em uma esfera dentro do fígado com centro e raio definidos nos arquivos de entrada do MCE. A partir deste ponto, os elétrons voam no espaço com ângulos polares e azimutais uniformemente sorteados nos seus domínios com energia inicial sorteada na tabela do espectro do Y-90 contida em um arquivo de entrada específico para o MSUPREE. A execução do MSUPREE produziu dados dosimétricos que permitem não apenas concluir que o acoplamento fantoma + fonte + código MC está correto, mas também que os autores, e pesquisadores do tema, dispõem de um novo MCE para dosimetria interna que pode ser aperfeiçoado para outras distribuições espaciais e energéticas de emissores beta.
- 4 February 2025
- Published by Brazilian Society for Computational and Applied Mathematics (SBMAC) in Trends in Computational and Applied Mathematics
- Vol. 26 (1)
Open AccessUm Novo Modelo Computacional De Exposição Para Simular A Radioembolização Usando O Ítrio 90m Novo Modelo Computacional De Exposição Para Simular A Radioembolização Usando O Ítrio 90
Para avaliar a energia depositada em órgãos e tecidos radiossensíveis do corpo humano é preciso desenvolver modelos computacionais de exposição (MCEs). Um MCE é composto por um fantoma (neologismo da palavra inglesa phantom) antropomórfico em posição matematicamente definida em relação a uma fonte radioativa. A fonte é um algoritmo destinado a produzir o estado inicial da simulação, isto é, o modo como o fantoma começa a ser irradiado. Usando técnicas Monte Carlo (MC) implementadas em robustos códigos disponíveis na comunidade científica, são simuladas as histórias das partículas, de interação em interação, até que suas energias estejam abaixo de um limiar de corte ou elas saiam do fantoma. Este trabalho apresenta um novo MCE chamado MSUPREE onde o fantoma é o MASHSup (Male Adult meSH in a Supine position), desenvolvido no DEN-UFPE, e o código MC é o EGSnrc (EGS = Electron Gamma Shower; nrc = National Research Council Canada). O algoritmo implementado da fonte consiste em um método não paramétrico desenvolvido pelos autores para gerar amostras de elétrons oriundos do decaimento do radionuclídeo ítrio 90 (Y-90), usado em radioembolização, um tratamento de tumores hepáticos. O estado inicial de um elétron é definido, principalmente, pela posição de largada, a direção de voo e a energia inicial. No MSUPREE os sorteios das posições iniciais ocorrem em uma esfera dentro do fígado com centro e raio definidos nos arquivos de entrada do MCE. A partir deste ponto, os elétrons voam no espaço com ângulos polares e azimutais uniformemente sorteados nos seus domínios com energia inicial sorteada na tabela do espectro do Y-90 contida em um arquivo de entrada específico para o MSUPREE. A execução do MSUPREE produziu dados dosimétricos que permitem não apenas concluir que o acoplamento fantoma + fonte + código MC está correto, mas também que os autores, e pesquisadores do tema, dispõem de um novo MCE para dosimetria interna que pode ser aperfeiçoado para outras distribuições espaciais e energéticas de emissores beta.
- 1 February 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 167, 108327
Solid standards for positron emitters
- 1 February 2020
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 167, 108327
Solid standards for positron emitters
- 1 January 2019
- Published by Inderscience Publishers in International Journal of Exergy
- Vol. 28 (4) , 380-403
Exergetic evaluation of a conceptual design for hydrogen production and seawater desalination using an advanced nuclear reactor as energy source
In this work, a computational model to develop the conceptual design for hydrogen production and seawater desalination based on a modular nuclear reactor as an energy source is presented. The four-step copper-chlorine (Cu-Cl) process is used to produce hydrogen coupled to the gas turbine modular helium reactor (GT-MHR) nuclear system through a Brayton cycle for the electrical energy generation. A fraction of the thermal energy from the GT-MHR system is used to reach and maintain the temperature requirements in the Cu-Cl process. The rejected heat from the oxy-decomposition reaction is used to desalinate seawater through a multi-stage flash (MSF) process. It is employed a chemical process simulator in order to develop a computational model of the proposed system. The global energy and exergy efficiencies of the proposal are 32.47% and 52.20% respectively, producing 0.2190 kg/s of hydrogen and desalinating 4.9492 kg/s of seawater. It is made an estimate of the cost of hydrogen produced using HEEP®, resulting in 2.77 $/kgH
- 1 January 2019
- Published by Inderscience Publishers in International Journal of Exergy
- Vol. 28 (4) , 380-403
Exergetic evaluation of a conceptual design for hydrogen production and seawater desalination using an advanced nuclear reactor as energy source
In this work, a computational model to develop the conceptual design for hydrogen production and seawater desalination based on a modular nuclear reactor as an energy source is presented. The four-step copper-chlorine (Cu-Cl) process is used to produce hydrogen coupled to the gas turbine modular helium reactor (GT-MHR) nuclear system through a Brayton cycle for the electrical energy generation. A fraction of the thermal energy from the GT-MHR system is used to reach and maintain the temperature requirements in the Cu-Cl process. The rejected heat from the oxy-decomposition reaction is used to desalinate seawater through a multi-stage flash (MSF) process. It is employed a chemical process simulator in order to develop a computational model of the proposed system. The global energy and exergy efficiencies of the proposal are 32.47% and 52.20% respectively, producing 0.2190 kg/s of hydrogen and desalinating 4.9492 kg/s of seawater. It is made an estimate of the cost of hydrogen produced using HEEP®, resulting in 2.77 $/kgH
- 1 January 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (3) , 1392-1408
Hydrogen production methods efficiency coupled to an advanced high-temperature accelerator driven system
- 1 January 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (3) , 1392-1408
Hydrogen production methods efficiency coupled to an advanced high-temperature accelerator driven system
- Open Access
- 27 December 2018
- Published by Springer Nature in EJNMMI Research
- Vol. 8 (1) , 112
Volume-of-interest-based supervised cluster analysis for pseudo-reference region selection in [18F]DPA-714 PET imaging of the rat brain
Aim of this study was to automatically select a suitable pseudo-reference brain region for the accurate, non-invasive quantification of neuroinflammation in a rat brain using dynamic [18F]DPA-714 PET imaging. A supervised clustering analysis approach considering three kinetic classes (SVCA3) was used to select an appropriate pseudo-reference brain region. This pseudo-reference region was determined by selecting only brain regions with low specific tracer uptake (SVCA3low) or by taking into account all brain regions and weighting each brain region with the corresponding fraction of low specific binding (SVCA3wlow). Both SVCA3 approaches were evaluated in an animal model of neuro-inflammation induced by lipopolysaccharide injection in the right striatum of female Wistar rats. For this study setup, a population of 25 female Wistar rats received a dynamic PET scan after injection of ~ 60 MBq [18F]DPA-714. Animals were scanned at baseline (n = 3) and at different time points after inducing neuroinflammation: 1 day (n = 3), 3 days (n = 12), 7 days (n = 4), and 30 days (n = 3). Binding potential (BP) values using a simplified reference tissue model (SRTM) and the contralateral striatum as pseudo-reference region were considered as a reference method (BPL STR) and compared with SRTM BP values using a pseudo-reference region obtained by either the SVCA3low or SVCA3wlow approach for both a 90- and 120-min acquisition time interval. For the right striatum, SRTM BP values using a SVCA3low- or SVCA3wlow-based pseudo-reference region demonstrated a strong and highly significant correlation with SRTM BPL STR values (Spearman r ≥ 0.89, p < 0.001). For the SVCA3low approach, Friedman tests revealed no significant difference with SRTM BPL STR values for a 120-min acquisition time while small but signification differences were found for a 90-min acquisition time (p < 0.05). For the SVCA3wlow approach, highly signification differences (p < 0.001) were found with SRTM BPL STR values for both a 90- and 120-min acquisition time interval. A SVCA3 approach using three kinetic classes allowed the automatic selection of pseudo-reference brain regions with low specific tracer binding for accurate and non-invasive quantification of rat brain PET imaging using [18F]DPA-714. A shorter acquisition time interval of 90 min can be considered with only limited impact on the SVCA3-based selection of the pseudo-reference brain regions.
- 27 December 2018
- Published by Springer Nature in EJNMMI Research
- Vol. 8 (1) , 112
Open AccessVolume-of-interest-based supervised cluster analysis for pseudo-reference region selection in [18F]DPA-714 PET imaging of the rat brain
Aim of this study was to automatically select a suitable pseudo-reference brain region for the accurate, non-invasive quantification of neuroinflammation in a rat brain using dynamic [18F]DPA-714 PET imaging. A supervised clustering analysis approach considering three kinetic classes (SVCA3) was used to select an appropriate pseudo-reference brain region. This pseudo-reference region was determined by selecting only brain regions with low specific tracer uptake (SVCA3low) or by taking into account all brain regions and weighting each brain region with the corresponding fraction of low specific binding (SVCA3wlow). Both SVCA3 approaches were evaluated in an animal model of neuro-inflammation induced by lipopolysaccharide injection in the right striatum of female Wistar rats. For this study setup, a population of 25 female Wistar rats received a dynamic PET scan after injection of ~ 60 MBq [18F]DPA-714. Animals were scanned at baseline (n = 3) and at different time points after inducing neuroinflammation: 1 day (n = 3), 3 days (n = 12), 7 days (n = 4), and 30 days (n = 3). Binding potential (BP) values using a simplified reference tissue model (SRTM) and the contralateral striatum as pseudo-reference region were considered as a reference method (BPL STR) and compared with SRTM BP values using a pseudo-reference region obtained by either the SVCA3low or SVCA3wlow approach for both a 90- and 120-min acquisition time interval. For the right striatum, SRTM BP values using a SVCA3low- or SVCA3wlow-based pseudo-reference region demonstrated a strong and highly significant correlation with SRTM BPL STR values (Spearman r ≥ 0.89, p < 0.001). For the SVCA3low approach, Friedman tests revealed no significant difference with SRTM BPL STR values for a 120-min acquisition time while small but signification differences were found for a 90-min acquisition time (p < 0.05). For the SVCA3wlow approach, highly signification differences (p < 0.001) were found with SRTM BPL STR values for both a 90- and 120-min acquisition time interval. A SVCA3 approach using three kinetic classes allowed the automatic selection of pseudo-reference brain regions with low specific tracer binding for accurate and non-invasive quantification of rat brain PET imaging using [18F]DPA-714. A shorter acquisition time interval of 90 min can be considered with only limited impact on the SVCA3-based selection of the pseudo-reference brain regions.
- Open Access
- 6 September 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (3)
Quimera: a simulation platform based on the code Geant4 for dose evaluation in radiotherapy
This work describes the development and validation of a simulation platform, called Quimera, based on the Monte Carlo (MC) code Geant4 for dose evaluation in radiotherapy. Quimera consists of two MC applications (qMATphantoms and qNCTphantoms) for dose evaluation from a phase-space and a graphical user interface (qGUI). qMATphantoms is aimed for modeling of physical phantoms used in quality control. NCT phantoms are built from computed tomography (CT) images of patient or physical phantom using a conversion method of CT numbers (NCT). qGUI has the function of creating or editing input files, running the MC applications and ana-lyzing results. MC applications were validated by comparison of dose distributions, whose results were in agreement with the quality assurance standards. qGUI is a differential concerning other Geant4 applications for radiotherapy and can be used for dose distribution analysis from other MC applications. Quimera can be used for research, simple treatment planning and quality assurance in photon beam radiotherapy
- 6 September 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (3)
Open AccessQuimera: a simulation platform based on the code Geant4 for dose evaluation in radiotherapy
This work describes the development and validation of a simulation platform, called Quimera, based on the Monte Carlo (MC) code Geant4 for dose evaluation in radiotherapy. Quimera consists of two MC applications (qMATphantoms and qNCTphantoms) for dose evaluation from a phase-space and a graphical user interface (qGUI). qMATphantoms is aimed for modeling of physical phantoms used in quality control. NCT phantoms are built from computed tomography (CT) images of patient or physical phantom using a conversion method of CT numbers (NCT). qGUI has the function of creating or editing input files, running the MC applications and ana-lyzing results. MC applications were validated by comparison of dose distributions, whose results were in agreement with the quality assurance standards. qGUI is a differential concerning other Geant4 applications for radiotherapy and can be used for dose distribution analysis from other MC applications. Quimera can be used for research, simple treatment planning and quality assurance in photon beam radiotherapy
- 1 July 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 105, 259-265
Implementing a test facility in reduced scale for analysis of boron dispersion in a pressurizer of an integral compact and modular reactor
- 1 July 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 105, 259-265
Implementing a test facility in reduced scale for analysis of boron dispersion in a pressurizer of an integral compact and modular reactor
- Open Access
- 14 April 2017
- Published by Brazilian Society for Computational and Applied Mathematics (SBMAC)
- Vol. 5 (1)
Uso de Técnicas Monte Carlo para Geração e Polimento de Imagens Ladrilhadas de Ossos Trabeculares.
Um dos maiores desafios em dosimetria numérica é estimar a energia depositada nos tecidos radiossensı́veis do esqueleto, as células hematopoéticas da medula óssea vermelha (MOV) e as células osteogênicas nas superfı́cies endeósteas dos ossos (CSO). A maior dificuldade em avaliar a dose (energia / massa) na MOV e nas CSO consiste em modelar as trabéculas ósseas. Os grupos de pesquisa a que pertencem os autores têm utilizando técnicas Monte Carlo (MC) para produzir blocos de imagens trabeculares. Neste trabalho, a esponjosa da cúpula craniana do adulto masculino representado pelo fantoma MASH (Male Adult meSH) do DEN-UFPE foi cortada e reamostrada. Então, técnicas MC foram usadas para produzir as trabéculas da região. As imagens dos blocos produzidos foram justapostas para compor imagens com as mesmas dimensões das reamostrada do MASH, similar à junção de ladrilhos na composição de um piso. As junções entre os “ladrilhos” foram polidas com filtros de moda estatı́stica. Por fim, foram utilizadas operações de lógica entre os pixels das imagens do MASH e as ladrilhadas para obter as imagens contendo o tecido trabecular separado do medular. Reamostrando todo o fantoma e trocando o seu tecido esponjoso por imagens como as produzidas para este trabalho, a dosimetria nos tecidos ósseos poderá ser realizada de modo similar à dos tecidos moles do corpo humano.
- 14 April 2017
- Published by Brazilian Society for Computational and Applied Mathematics (SBMAC)
- Vol. 5 (1)
Open AccessUso de Técnicas Monte Carlo para Geração e Polimento de Imagens Ladrilhadas de Ossos Trabeculares.
Um dos maiores desafios em dosimetria numérica é estimar a energia depositada nos tecidos radiossensı́veis do esqueleto, as células hematopoéticas da medula óssea vermelha (MOV) e as células osteogênicas nas superfı́cies endeósteas dos ossos (CSO). A maior dificuldade em avaliar a dose (energia / massa) na MOV e nas CSO consiste em modelar as trabéculas ósseas. Os grupos de pesquisa a que pertencem os autores têm utilizando técnicas Monte Carlo (MC) para produzir blocos de imagens trabeculares. Neste trabalho, a esponjosa da cúpula craniana do adulto masculino representado pelo fantoma MASH (Male Adult meSH) do DEN-UFPE foi cortada e reamostrada. Então, técnicas MC foram usadas para produzir as trabéculas da região. As imagens dos blocos produzidos foram justapostas para compor imagens com as mesmas dimensões das reamostrada do MASH, similar à junção de ladrilhos na composição de um piso. As junções entre os “ladrilhos” foram polidas com filtros de moda estatı́stica. Por fim, foram utilizadas operações de lógica entre os pixels das imagens do MASH e as ladrilhadas para obter as imagens contendo o tecido trabecular separado do medular. Reamostrando todo o fantoma e trocando o seu tecido esponjoso por imagens como as produzidas para este trabalho, a dosimetria nos tecidos ósseos poderá ser realizada de modo similar à dos tecidos moles do corpo humano.
- Open Access
- 8 November 2016
- Published by Revista de Engenharia e Pesquisa Aplicada in Revista de Engenharia e Pesquisa Aplicada
- Vol. 2 (1)
Modelagem Computacional para Acidentes de Reatividade em Reatores Nucleares
Reatores nucleares de pesquisa são comumente localizados em universidades e vastamente utilizados para desenvolvimento de novos procedimentos operacionais. O reator IPR-R1 TRIGA, localizado no Centro de Desenvolvimento da Tecnologia Nuclear, tem utilização destacada na produção de radioisótopos e no treinamento de pessoal. Atualmente o IPR-R1 passa por um processo de licenciamento para trabalhar a 250kW. Neste trabalho, é utilizado o codigo PARET- Program for the Analysis of Reactor Transients, para simular inserções de reatividade e verificar o comportamento dos parâmetros de segurança nessa nova potência de 250kW.
- 8 November 2016
- Published by Revista de Engenharia e Pesquisa Aplicada in Revista de Engenharia e Pesquisa Aplicada
- Vol. 2 (1)
Open AccessModelagem Computacional para Acidentes de Reatividade em Reatores Nucleares
Reatores nucleares de pesquisa são comumente localizados em universidades e vastamente utilizados para desenvolvimento de novos procedimentos operacionais. O reator IPR-R1 TRIGA, localizado no Centro de Desenvolvimento da Tecnologia Nuclear, tem utilização destacada na produção de radioisótopos e no treinamento de pessoal. Atualmente o IPR-R1 passa por um processo de licenciamento para trabalhar a 250kW. Neste trabalho, é utilizado o codigo PARET- Program for the Analysis of Reactor Transients, para simular inserções de reatividade e verificar o comportamento dos parâmetros de segurança nessa nova potência de 250kW.
- Open Access
- 20 April 2015
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 3 (1A)
Validação da simulação do feixe de prótons
Validação da simulação do feixe de prótons
- 20 April 2015
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 3 (1A)
Open AccessValidação da simulação do feixe de prótons
Validação da simulação do feixe de prótons