TOTakashi Okajima

Takashi Okajima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takashi Okajima has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The current status of reflector production and hard x-ray characterization for ASTRO-H/HXT

    by Takuya Miyazawa, Akihiro Furuzawa, Yasufumi Kanou, Kenji Matsuda, Michito Sakai, Nobuyuki Yamane, Hiroyoshi Kato, Yusuke Miyata, Karin Sakanobe, Yoshito Haba, et al.

    Japan's sixth X-ray satellite mission ASTRO-H is planned to be launched in 2014. Hard X-ray Telescope (HXT) to cover hard X-rays up to 80 keV is thin-foil, multi-nested conical optics with depth-graded Pt/C multilayer. The mass production of the reflectors for the flight model has been going on since August 2010. We have introduced a new screening method for replication mandrels with optical imagers. In addition, we have adopted a new replication mandrel which consists of glass tube coated with thin glass sheet for large size mandrels. The selected 212 pairs (95 pairs (segment 1), 59 pairs (segment 2), 58 pairs (segment 3)) of multilayer mirror have been characterized at a large synchrotron radiation facility, Spring-8 beamline BL20B2. We present the current status of reflector production and hard X-ray characterization for HXT.

  • The current status of the reflector production for ASTRO-H/HXT

    by Akihiro Furuzawa, Takuya Miyazawa, Kanou Yasufumi, Kenji Matsuda, Michito Sakai, Yosuke Ishida, Shinji Hara, Koudai Yamane, Nobuyuki Yamane, Yusuke Miyata, et al.

    Japan's 6th X-ray satellite mission ASTRO-H, which is planed to be launched in the fiscal year 2013, will carry two hard X-ray telescopes (HXT) using depth-graded multilayer reflectors which provide us the capability of hard X-ray imaging observation up to 80 keV. ASTRO-H/HXT is the light-weight hard X-ray telescope using Pt/C depth-graded multilayer and high-throughput thin-foil optics. The basic technology for fabricating ASTROH /HXT has been established through the balloon borne experiments, InFOCμS and SUMIT mission. The HXT consists of about 1300 foil reflectors of which a size of the 200 mm mirror length and the diameter range of 120-450 mm which is much larger that those for the balloon borne experiments. To clear the requirements of the angular resolution and the effective photon collecting area for ASTRO-H/HXT, we should produce twice the total number of reflectors and select them. Therefore we need to produce more than 5000 foil reflectors for the two flight telescopes. The installation of the production line and optical evaluation system dedicated to the ASTRO-H/HXT has been almost done. We are testing and improving the production line through productions of several sizes of reflectors. The mass production of the reflectors for the flight model is scheduled to start from July 2010.


  • The NeXT x-ray telescope system: status update

    by Yasushi Ogasaka, Hideyo Kunieda, Takuya Miyazawa, Peter Serlemitsos, Yang Soong, Takashi Okajima, Yoshitomo Maeda, Hideyuki Mori, Manabu Ishida, Hisamitsu Awaki, et al.

    Japan's NeXT mission has been approved for the Phase-A in 2007. At present NeXT is in the process of transition to the Phase-B. One of the unique feature of the mission is an imaging spectroscopy in unprecedentedly wide energy region from 0.5 to 80 keV. The X-Ray Telescope (XRT) system covers the energy region by means of grazing incidence reflective optics. International collaboration has been formed for the project and design and basic study have been carried out so far. Current baseline specification includes two hard X-ray telescopes which are combined with the Hard X-ray Imager (Si + CdTe pixel or strip) and cover 5 to 80 keV, and two soft X-ray telescopes which cover 0.3 to about 20 keV, one combined with a high resolution X-ray micro-calorimeter and the other with an X-ray CCD. Both of hard and soft X-ray mirrors employ same optical design; tightly-nested, conically-approximated thin-foil Wolter-I optics. The mission requirements for XRT system have been identified as 300 cm2 at 30 keV for the hard X-ray telescope in total and 400 cm2 at 6 keV for the soft X-ray telescope per unit. The requirement on the point spread function is 1.7 arcmin in HPD, as well as the goal being 1.2 arcmin. Based on the current level of technology all the mission requirements are expected to be satisfied.


  • Design study of telescope housing for the NeXT/XRT

    by Hisamitsu Awaki, Keiji Ogi, Takashi Okajima, Peter J. Serlemitsos, Yang Soong, Kai-Wing Chan, Yasushi Ogasaka, Takuya Miyazawa, Akihiro Furuzawa, Hideyo Kunieda, et al.

    We present a study on housing design for the X-ray telescopes (XRT) onboard the New Exploration X-ray Telescope (NeXT). The NeXT XRTs are larger than previous thin-foil XRTs. The XRT is required to have a sufficient stiffness in order to keep the high performance of the XRT in orbit. We performed a structure analysis of the virtual model of the NeXT XRT housing using the FEA software Marc. A virtual model of the NeXT XRT was designed based on the XRT of the SUMIT balloon experiment. From the structure analysis of the virtual model by Marc, we found that the displacement of the XRT housing is small. The maximum displacement is a few µm, which is satisfied with our goal of 10 µm. On the other hand, the alignment bars show a large displacement up to about 90 µm. This is caused because the alignment bars become longer, and the total weight of the thin foils increases due to the larger effective area. This analysis indicates that we have to use stiff alignment bars without reducing the effective area. This result is useful to design a proto-model of the XRT housing. We will examine the result of this FEA analysis by measuring the displacement of the proto-model.


  • Soft x-ray calibration for the NeXT x-ray telescope

    by Yoshitomo Maeda, Takayuki Hayashi, Hideyuki Mori, Ryoko Nakamura, Takuro Satoh, Akiko Sekiguchi, Kentaro Someya, Kensuke Tamura, Manabu Ishida, Takeyuki Osawa, et al.

    We present a plan on soft X-ray calibration for the New Exploration X-ray Telescope (NeXT). Two hard and two soft X-ray telescopes (HXTs/SXTs: see Ogasaka et al. 2008 in this volume) provide images up to 80 keV with a large effective area. Following to the Suzaku X-ray telescope, the mirrors on SXTs are tightly nested to maximize the aperture efficiency. To illuminate the mirrors at all, we plan to adopt a raster scan system using a pencil beam collimated from an X-ray generator. We summarize a current status of the soft X-ray ground calibration system at ISAS/JAXA. We also review the calibration of the Suzaku XRTs since the optics are very similar to the NeXT SXTs.


  • Design and technology review of the x-ray telescope system onboard NeXT mission

    by Yasushi Ogasaka, Keisuke Tamura, Ryo Shibata, Takashi Okajima, Akihiro Furuzawa, Hideyo Kunieda, Yoshitomo Maeda, Manabu Ishida, Hisamitsu Awaki

    Japan's 6th X-ray satellite mission NeXT has completed pre-Phase-A study, and is waiting to advance to Phase-A/B. The X-Ray Telescope System onboard NeXT covers wide energy range from 0.3 to 80 KeV. The paper reviews current status on design and technology of the mission as written in the NeXT Mission Proposal on Oct. 2005.


  • Characterization of the supermirror hard-x-ray telescope for the InFOCµS balloon experiment

    by Takashi Okajima, Keisuke Tamura, Yasushi Ogasaka, Kazutoshi Haga, Seiji Takahashi, Satoshi Ichimaru, Hideo Kito, Shin’ichi Fukuda, Arifumi Goto, Kentaro Nomoto, et al.

    Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.