JWJulia Walther

Julia Walther

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Julia Walther has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of carious lesions utilizing depolarization imaging by polarization sensitive optical coherence tomography

    by Jonas Golde, Florian Tetschke, Julia Walther, Tobias Rosenauer, Franz Hempel, Christian Hannig, Edmund Koch, Lars Kirsten

    The early identification of proximal carious lesions is still one of the most challenging issues in modern cariology and odontology, whereas several visual, optical, and radiographic techniques have been developed and improved in recent years.1,2 Providing depth-resolved, high-resolution images of biological samples, optical coherence tomography (OCT) is a promising tool for detecting caries noninvasively, since first investigations of dental hard tissue in vitro and in vivo were performed by OCT,3,4 and imaging in the near-infrared range proved convenient scattering and absorption properties.5 So far, OCT has shown the potential to provide effective and reproducible diagnoses for clinical applications,6 and algorithms that enable early caries segmentation from conventional OCT images have been presented.7 Additionally to the structural imaging based on backscattering intensities, miscellaneous modalities and extensions for OCT have been developed, which provide tissue-dependent contrast. This includes polarization sensitive imaging and the consequent measurement of depth-resolved birefringence, which until now has been applied in many biomedical as well as nonmedical fields.8,9 In terms of hard dental tissue and caries detection, first polarization sensitive OCT (PS-OCT) measurements confirmed the birefringent properties of enamel and dentin,4,10 and it was determined that demineralization, accompanying carious infections, results in depolarization of light.11 Since then, several studies have shown the potential of PS-OCT to observe the internal structure and the remineralization of lesions, as well as an early detection of variously located caries.12 13. – 14 Thereby, the occurring depolarization effect for linearly polarized incident light is usually evaluated by an intensity measurement of the perpendicular polarization state.15


  • Open Access

    Functional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography

    by Lars Kirsten, Joseph Morgenstern, Mikael Timo Erkkilä, Martin Schindler, Jonas Golde, Julia Walther, Max Kemper, Thomas Stoppe, Matthias Bornitz, Marcus Neudert, et al.

    In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.


  • High Speed optische Kohärenztomografie als vielversprechendes Bildgebungsverfahren bei der Untersuchung des Blasensiedens

    by Lars Kirsten, Thomas Domaschke, Julia Walther, Sven Meissner, Clemens Schneider, Rainer Hampel, Edmund Koch

    Zusammenfassung Es wird die High Speed optische Kohärenztomografie (OCT) als alternatives und komplementäres Messverfahren für die Bildgebung des Blasensiedens an beheizten Oberflächen vorgestellt. Mit High Speed OCT können Dampfblasen räumlich und zeitlich hochaufgelöst visualisiert werden, wobei sich die Blasengeometrie mit einem Segmentierungs- und Trackingalgorithmus automatisiert quantifizieren lässt. Darüber hinaus ermöglicht die Doppler-OCT die simultane Messung der axialen Geschwindigkeitskomponente des Fluids.

  • Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh

    by Lars Kirsten, Anke Burkhardt, Jonas Golde, Julia Walther, Thomas Stoppe, Matthias Bornitz, Max Kemper, Thomas Zahnert, Edmund Koch

    Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.


  • Resolution improvement in dual-band OCT by filling the spectral gap

    by Peter Cimalla, Maria Gaertner, Julia Walther, Edmund Koch

    In most dual-band OCT systems, there is a spectral gap between both bands. This might be as large as one third of the total spectral region. Therefore, a simple Fourier transformation of the data does not give the resolution that could be possible considering the overall spectral width. Instead, the full width of the peak is comparable to the width resulting from a single band and is additionally modulated. We compare several methods to achieve a high resolution in spite of the missing data. Because in a dual-band system the image quality resulting from the full information is not known we test and optimize different algorithms by using the data from a single band system and excluding an equal part of the spectrum. While methods using non-equidistant sample points like Vandermonde and Lomb transformation work well with small spectral gaps, they result in large image artifacts for broader gaps, which are typical for dual-band OCT systems. Simulations show that fitting the available data with a limited set of sine and cosines functions might give good results but for larger gaps and appropriate amount of basis-functions this method fails, too. Dividing both bands into overlapping smaller bands and looking at the phase of short-time Fourier transformations (STFT) resulting from a single scatterer, it becomes clear that the amplitude of all Fourier coefficients for the total band can be estimated by the change of the phase of the STFTs in and between both bands. Therefore, we developed an algorithm of weighting the data based on the phase distribution of the STFT data. As a single value specifying the phase distribution we choose the absolute sum of the STFTs divided by the sum of the amplitudes of the STFTs. Because typical OCT data are not caused by single scatterers, we adapted this algorithm with a cluster analysis to predict the appropriate amplitude expected for a full spectrum from the phase distribution of the STFTs inside both bands and between both bands. Although the image is noisier and fainter compared to an image from the full spectrum, the resulting image has the best resolution from all methods investigated.


  • Axial resolution improvement by spectral data fusion in simultaneous dual-band optical coherence tomography

    by Peter Cimalla, Maria Gaertner, Julia Walther, Edmund Koch

    A method for axial resolution improvement by adequate spectral data fusion of two parallel acquired disjunct wavelength bands in the 0.8 μm and 1.3 μm region in the field of simultaneous dual-band optical coherence tomography (OCT) is presented. The applied spectral domain dual-band OCT system is illuminated by a supercontinuum laser light source and allows simultaneous imaging at 800 nm and 1250 nm with free-space axial resolutions better than 4.5 μm and 7 μm, respectively, over the entire depth scan range. Each wavelength band is analyzed with an individual spectrometer at an A-scan rate of 12 kHz. To further improve axial resolution, the 1250 nm spectra are fused with the 800 nm spectra considering the spectrometer-inherent non-linear fringe frequency course of the interference light. The phase and amplitude of the 1250 nm spectra are matched to the 800 nm spectra by means of short time Fourier transform analysis in order to obtain ideally continuous joint spectra. The joint spectra then undergo conventional spectral shaping, wave number resampling, windowing and fast Fourier transformation. First results for single A-scans of a glass slide as well as entire cross-sectional images of biological tissue yield an axial resolution improvement of 52 % compared to conventional single band imaging at 800 nm. The obtained A-scans show a good sharpness with a side lobe suppression of 30 dB. Additional investigations have to be employed for the full understanding of the underlying physical background and the optimization of the applied data processing for further image quality enhancement.

  • Optical coherence tomography for imaging of subpleural alveolar structure using a Fourier domain mode locked laser

    by Lars Kirsten, Julia Walther, Peter Cimalla, Maria Gaertner, Sven Meissner, Edmund Koch

    Optical coherence tomography (OCT) is a noninvasive imaging modality generating cross sectional and volumetric images of translucent samples. In Fourier domain OCT (FD OCT), the depth profile is calculated by a fast Fourier transformation of the interference spectrum, providing speed and SNR advantage and thus making FD OCT well suitable in biomedical applications. The interference spectrum can be acquired spectrally resolved in spectral domain OCT or time-resolved in optical frequency domain imaging (OFDI). Since OCT images still suffer from motion artifacts, especially under in vivo conditions, increased depth scan rates are required. Therefor, the principle of Fourier domain mode locking has been presented by R. Huber et al. circumventing the speed limitations of conventional FD OCT systems. In FDML lasers, a long single mode fiber is inserted in the ring resonator of the laser resulting in an optical round trip time of a few microseconds. Sweeping the wavelength synchronously by a tunable Fabry-Perot filter can provide wavelength sweeps with repetition rates up to a few MHz used for OFDI. Imaging of subpleural lung tissue for investigation of lung dynamics and its elastic properties is a further biomedical application demanding high-speed OCT imaging techniques. For the first time, the visualization of subpleural alveolar structures of a rabbit lung is presented by the use of an FDML-based OCT system enabling repetition rates of 49.5 kHz and 122.6 kHz, respectively.


  • Endoscopic optical coherence tomography for imaging the tympanic membrane

    by Anke Burkhardt, Julia Walther, Peter Cimalla, Matthias Bornitz, Edmund Koch

    Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.


  • Enhanced joint spectral and time domain optical coherence tomography for quantitative flow velocity measurement

    by Julia Walther, Edmund Koch

    Recently, a new method called joint spectral and time domain optical coherence tomography (STdOCT) for flow velocity measurement in spectral domain OCT (SD OCT) was presented. This method analyzes the detected timeresolved interference fringe spectra by using a two-dimensional fast Fourier transformation (2D FFT) to determine directly the Doppler frequency shift instead of calculating the phase difference at each depth position of adjacent A-scans. There, it was found that STdOCT is more robust for measurements with low signal to noise ratio than the classic phase-resolved Doppler OCT (DOCT) making it attractive first for imaging fast flow velocities at which a strong Doppler angle dependent signal damping occurs due to interference fringe washout and second for investigating large blood vessels with a big diameter and a highly damped signal of blood with increasing depth due to strong scattering and absorption in the near-infrared wavelength range. In the present study, we would like to introduce an enhanced algorithm for STdOCT permitting a more precise flow velocity measurement in comparison to the conventional STdOCT. The new method determines the amplitude of the broadened Doppler frequency shift by calculating the center of gravity via the complex analytical signal as a result of the second FFT instead of detecting the maximum intensity signal. Furthermore, the comparison with phase-resolved DOCT was done experimentally by using a flow phantom consisting of a 1% Intralipid emulsion and a 320 μm glass capillary. As a result, the enhanced STdOCT and DOCT processed data are completely equivalent.


  • Lateral resonant Doppler imaging for quantitative flow extraction in spectral domain optical coherence tomography

    by Julia Walther, Peter Cimalla, Edmund Koch

    In spectral domain Doppler OCT, any transverse motion component of the obliquely moving sample relative to the incident sample beam causes a damping of the correlation between subsequent backscattering signals or even the loss of it making a phase-resolved Doppler flow analysis difficult because of the strong mean error of the Doppler phase shift. To circumvent this effect, a new method for resonant Doppler flow imaging and quantification in spectral domain OCT is proposed where the scanner movement velocity is approximately matched to the transverse velocity component of the oblique sample motion similar to a tracking shot where the camera is moved with respect to the sample. As a result, the backscattering signals corresponding to the moving sample will be highly correlated whereas those of static sample structures and slowly moving scatterers will be less correlated and damped depending on the scanner velocity. Advantageously, for the exact flow velocity quantification the new Doppler relationship of phase shift and sample velocity has not to be applied and the linear relation of the classic Doppler model can still be used. In the present work, first results of the lateral resonant Doppler imaging are shown for an 1 percent Intralipid flow phantom study.