Lars Kirsten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lars Kirsten has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Edmund Koch
Clinical Sensoring and Monitoring, Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, TU Dresden, Dresden, Germany
11 shared publications - Jonas Golde
Fraunhofer Institute for Material and Beam Technology IWS, Dresden , Germany
7 shared publications - Julia Walther
Technische Univ. Dresden (Germany)
5 shared publications - Matthias Bornitz
Technische Univ. Dresden (Germany)
3 shared publications - Max Kemper
Department of Otolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Germany
3 shared publications - Sven Meissner
Faculty of Medicine Carl Gustav Carus, Dresden Univ. of Technology (Germany)
3 shared publications
Latest Publications
- Open Access
- 7 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (4) , 367
Polarization-Sensitive Optical Coherence Tomography for Monitoring De- and Remineralization of Bovine Enamel In Vitro
Early caries diagnosis still challenges dentistry. Polarization-sensitive optical coherence tomography (PS-OCT) is promising to detect initial lesions non-invasively in depth-resolved cross-sectional visualization. PS-OCT with determined degree of polarization (DOP) imaging provides an intuitive demineralization contrast. The aim of this study is to evaluate the suitability of DOP-based PS-OCT imaging to monitor controlled de- and remineralization progression for the first time and to introduce it as a valid, non-destructive in vitro detection method. Twelve standardized bovine enamel specimens were divided in different groups and demineralized with hydrochloric acid (HCl) as well as partly remineralized with fluoride over a 14-day pH-cycling experiment. The specimens were stored in artificial saliva and sodium chloride (NaCl), respectively. Progress measurements with PS-OCT were made with polarization-sensitive en faceand B-scan mode for qualitative evaluation. The specimens demineralized in HCl showed the most pronounced surface change (lowest DOP) and the most significant increase in depolarization. Additional fluoride treatment and the storage in artificial saliva resulted in the opposite (highest DOP). Therefore, DOP-based PS-OCT imaging appears to be a valuable technique for visualization and monitoring of enamel demineralization and remineralization processes in vitro. However, these findings need to be confirmed in human teeth ex vivo or in situ.
- 7 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (4) , 367
Open AccessPolarization-Sensitive Optical Coherence Tomography for Monitoring De- and Remineralization of Bovine Enamel In Vitro
Early caries diagnosis still challenges dentistry. Polarization-sensitive optical coherence tomography (PS-OCT) is promising to detect initial lesions non-invasively in depth-resolved cross-sectional visualization. PS-OCT with determined degree of polarization (DOP) imaging provides an intuitive demineralization contrast. The aim of this study is to evaluate the suitability of DOP-based PS-OCT imaging to monitor controlled de- and remineralization progression for the first time and to introduce it as a valid, non-destructive in vitro detection method. Twelve standardized bovine enamel specimens were divided in different groups and demineralized with hydrochloric acid (HCl) as well as partly remineralized with fluoride over a 14-day pH-cycling experiment. The specimens were stored in artificial saliva and sodium chloride (NaCl), respectively. Progress measurements with PS-OCT were made with polarization-sensitive en faceand B-scan mode for qualitative evaluation. The specimens demineralized in HCl showed the most pronounced surface change (lowest DOP) and the most significant increase in depolarization. Additional fluoride treatment and the storage in artificial saliva resulted in the opposite (highest DOP). Therefore, DOP-based PS-OCT imaging appears to be a valuable technique for visualization and monitoring of enamel demineralization and remineralization processes in vitro. However, these findings need to be confirmed in human teeth ex vivo or in situ.
- Open Access
- 24 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (8) , 2971
Correlation between Lesion Progression and Depolarization Assessed by Polarization-Sensitive Optical Coherence Tomography
The detection of early stages of caries is still one of the major challenges in preservative dentistry. Since it is known from polarized light microscopy (PLM) that intrinsic enamel birefringence is affected by demineralization, polarization-sensitive optical coherence tomography (PSOCT) could facilitate the noninvasive detection and assessment of early carious lesions. The present study aims to correlate enamel lesion progression and depolarization measurements based on PSOCT in an artificial demineralization model. A total of 18 enamel slabs were prepared from bovine incisor teeth and demineralized in an acetic buffer solution for up to 49 days. The degree of polarization (DOP)—indicating depolarization and thus, demineralization—was calculated from PSOCT measurements and compared to lesion depth which was measured from PLM images. Artificial lesions showed characteristic zones of natural enamel demineralization in PLM images. DOP representations showed no depolarization for sound, nondemineralized enamel, whereas significant changes were found after 15 days of acid-exposition. The linear regression analysis of the DOP and the measured lesion depth showed a substantial correlation ( ). The results indicate that PSOCT-based depolarization imaging provides an unambiguous contrast for initial enamel demineralization which is correlated to the lesion progression.- 24 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (8) , 2971
Open AccessCorrelation between Lesion Progression and Depolarization Assessed by Polarization-Sensitive Optical Coherence Tomography
The detection of early stages of caries is still one of the major challenges in preservative dentistry. Since it is known from polarized light microscopy (PLM) that intrinsic enamel birefringence is affected by demineralization, polarization-sensitive optical coherence tomography (PSOCT) could facilitate the noninvasive detection and assessment of early carious lesions. The present study aims to correlate enamel lesion progression and depolarization measurements based on PSOCT in an artificial demineralization model. A total of 18 enamel slabs were prepared from bovine incisor teeth and demineralized in an acetic buffer solution for up to 49 days. The degree of polarization (DOP)—indicating depolarization and thus, demineralization—was calculated from PSOCT measurements and compared to lesion depth which was measured from PLM images. Artificial lesions showed characteristic zones of natural enamel demineralization in PLM images. DOP representations showed no depolarization for sound, nondemineralized enamel, whereas significant changes were found after 15 days of acid-exposition. The linear regression analysis of the DOP and the measured lesion depth showed a substantial correlation ( ). The results indicate that PSOCT-based depolarization imaging provides an unambiguous contrast for initial enamel demineralization which is correlated to the lesion progression. - Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 227-230
Polarization sensitive optical coherence tomography utilizing a buffered swept source laser
We present an approach for polarization sensitive optical coherence tomography (PS-OCT) that solely requires a modification of the light source, a buffered swept source laser. For this purpose a single-mode fiber-based Fourier domain mode locked laser is extended by fourfold buffering with manual fiber polarization controllers to emit alternating sweep polarizations, while the polarization contrast calibration is realized by a high-speed polarimeter. As the introduced setup utilizes standard scanning and detection units, the proposed method is a promising way to enhance various swept source OCT systems by polarization sensitive imaging. Preliminary measurements of a human finger nail with different polarization contrasts demonstrate the feasibility of the concept.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 227-230
Open AccessPolarization sensitive optical coherence tomography utilizing a buffered swept source laser
We present an approach for polarization sensitive optical coherence tomography (PS-OCT) that solely requires a modification of the light source, a buffered swept source laser. For this purpose a single-mode fiber-based Fourier domain mode locked laser is extended by fourfold buffering with manual fiber polarization controllers to emit alternating sweep polarizations, while the polarization contrast calibration is realized by a high-speed polarimeter. As the introduced setup utilizes standard scanning and detection units, the proposed method is a promising way to enhance various swept source OCT systems by polarization sensitive imaging. Preliminary measurements of a human finger nail with different polarization contrasts demonstrate the feasibility of the concept.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 99-101
Functional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography
In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 99-101
Open AccessFunctional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography
In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 443-447
Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
The treatment of otitis media requires classifying the effusion in the tympanic cavity for choosing appropriate therapeutic strategies. Otoscopic examination of the middle ear depends on the expertise of the physician and is often hampered in case of inflammatory alterations of the tympanic membrane. In otologic research, optical coherence tomography is an innovative non-invasive imaging technique utilized for visualizing the tympanic membrane. This ex vivo study presents the possibility of OCT and Doppler-OCT for the detection of effusions in the tympanic cavity. Structural OCT imaging allows the direct visualization of scattering fluids behind the tympanic membrane. In addition, the measurement of the reduced oscillation amplitude by means of Doppler-OCT permits the indirect detection of scattering and transparent fluids.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 443-447
Open AccessDoppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
The treatment of otitis media requires classifying the effusion in the tympanic cavity for choosing appropriate therapeutic strategies. Otoscopic examination of the middle ear depends on the expertise of the physician and is often hampered in case of inflammatory alterations of the tympanic membrane. In otologic research, optical coherence tomography is an innovative non-invasive imaging technique utilized for visualizing the tympanic membrane. This ex vivo study presents the possibility of OCT and Doppler-OCT for the detection of effusions in the tympanic cavity. Structural OCT imaging allows the direct visualization of scattering fluids behind the tympanic membrane. In addition, the measurement of the reduced oscillation amplitude by means of Doppler-OCT permits the indirect detection of scattering and transparent fluids.
- 28 October 2015
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 82 (11) , 562-571
High Speed optische Kohärenztomografie als vielversprechendes Bildgebungsverfahren bei der Untersuchung des Blasensiedens
Zusammenfassung Es wird die High Speed optische Kohärenztomografie (OCT) als alternatives und komplementäres Messverfahren für die Bildgebung des Blasensiedens an beheizten Oberflächen vorgestellt. Mit High Speed OCT können Dampfblasen räumlich und zeitlich hochaufgelöst visualisiert werden, wobei sich die Blasengeometrie mit einem Segmentierungs- und Trackingalgorithmus automatisiert quantifizieren lässt. Darüber hinaus ermöglicht die Doppler-OCT die simultane Messung der axialen Geschwindigkeitskomponente des Fluids.
- 28 October 2015
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 82 (11) , 562-571
High Speed optische Kohärenztomografie als vielversprechendes Bildgebungsverfahren bei der Untersuchung des Blasensiedens
Zusammenfassung Es wird die High Speed optische Kohärenztomografie (OCT) als alternatives und komplementäres Messverfahren für die Bildgebung des Blasensiedens an beheizten Oberflächen vorgestellt. Mit High Speed OCT können Dampfblasen räumlich und zeitlich hochaufgelöst visualisiert werden, wobei sich die Blasengeometrie mit einem Segmentierungs- und Trackingalgorithmus automatisiert quantifizieren lässt. Darüber hinaus ermöglicht die Doppler-OCT die simultane Messung der axialen Geschwindigkeitskomponente des Fluids.
- 9 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9541, 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.
- 9 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9541, 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.
- 28 February 2015
- Published by Springer Nature in Experiments in Fluids
- Vol. 56 (3) , 1-13
Visualization of dynamic boiling processes using high-speed optical coherence tomography
- 28 February 2015
- Published by Springer Nature in Experiments in Fluids
- Vol. 56 (3) , 1-13
Visualization of dynamic boiling processes using high-speed optical coherence tomography
- 1 January 2015
- Published by Optica Publishing Group
- p. 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.
- 1 January 2015
- Published by Optica Publishing Group
- p. 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.
- 1 June 2014
- Published by Elsevier in Food Chemistry
- Vol. 153, 444-449
Feasibility of non-invasive detection of engineered nanoparticles in food mimicking matrices by Optical Coherence Tomography
- 1 June 2014
- Published by Elsevier in Food Chemistry
- Vol. 153, 444-449
Feasibility of non-invasive detection of engineered nanoparticles in food mimicking matrices by Optical Coherence Tomography