Bennett B. Goldberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bennett B. Goldberg has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Selim Unlu
Department of Electrical and Computer Engineering, Boston University, Boston, USA
11 shared publications - Anna K. Swan
Department of Electrical Engineering, Boston University, Boston, Massachusetts 02215, United States
5 shared publications Abdulkadir Yurt
Division of Materials Science and Engineering, Boston University, Brookline, Massachusetts, USA
2 shared publicationsAyca Yalcin
College of Engineering, Boston University, Boston, MA 02215 USA (;;;;;;)
2 shared publications- Yan Yin
Department of Physics, Boston University, Boston, Massachusetts 02215, USA
2 shared publications - Yang Lu
Boston University, Boston, MA, USA
2 shared publications
Latest Publications
- Open Access
Long tailed trions in monolayer MoS$_2$: Temperature dependent asymmetry and red-shift of trion photoluminescence spectra
Monolayer molybdenum disulfide (MoS$_2$) has emerged as an excellent 2D model system because of its two inequivalent, direct-gap valleys that lead to exotic bound and excited states. Here we focus on one such bound state, the negatively charged trion. Unlike excitons, trions can radiatively decay with non-zero momentum by kicking out an electron, resulting in an asymmetric trion photoluminescence (PL) peak with a long low-energy tail. As a consequence, the peak position does not correspond to the zero momentum trion energy. By including the trion's long tail in our analysis we are able to accurately separate the exciton from the trion contributions to the PL spectra. According to theory, the asymmetric energy tail has both a size-dependent and a temperature-dependent contribution. Analysis of the temperature-dependent data reveals the effective trion size, consistent with literature, and the temperature dependence of the band gap and spin-orbit splitting of the valence band. Finally, we observe signatures of Pauli-blocking of the trion decay.
Open AccessLong tailed trions in monolayer MoS$_2$: Temperature dependent asymmetry and red-shift of trion photoluminescence spectra
Monolayer molybdenum disulfide (MoS$_2$) has emerged as an excellent 2D model system because of its two inequivalent, direct-gap valleys that lead to exotic bound and excited states. Here we focus on one such bound state, the negatively charged trion. Unlike excitons, trions can radiatively decay with non-zero momentum by kicking out an electron, resulting in an asymmetric trion photoluminescence (PL) peak with a long low-energy tail. As a consequence, the peak position does not correspond to the zero momentum trion energy. By including the trion's long tail in our analysis we are able to accurately separate the exciton from the trion contributions to the PL spectra. According to theory, the asymmetric energy tail has both a size-dependent and a temperature-dependent contribution. Analysis of the temperature-dependent data reveals the effective trion size, consistent with literature, and the temperature dependence of the band gap and spin-orbit splitting of the valence band. Finally, we observe signatures of Pauli-blocking of the trion decay.
- 24 March 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (7) , 7422-7433
Evanescent waves in high numerical aperture aplanatic solid immersion microscopy: Effects of forbidden light on subsurface imaging
The collection of light at very high numerical aperture allows detection of evanescent waves above the critical angle of total internal reflection in solid immersion lens microscopy. We investigate the effect of such evanescent modes, so-called forbidden light, on the far-field imaging properties of an aplanatic solid immersion microscope by developing a dyadic Green’s function formalism in the context of subsurface semiconductor integrated circuit imaging. We demonstrate that the collection of forbidden light allows for sub-diffraction spatial resolution and substantial enhancement of photon collection efficiency albeit inducing wave-front discontinuities and aberrations.
- 24 March 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (7) , 7422-7433
Evanescent waves in high numerical aperture aplanatic solid immersion microscopy: Effects of forbidden light on subsurface imaging
The collection of light at very high numerical aperture allows detection of evanescent waves above the critical angle of total internal reflection in solid immersion lens microscopy. We investigate the effect of such evanescent modes, so-called forbidden light, on the far-field imaging properties of an aplanatic solid immersion microscope by developing a dyadic Green’s function formalism in the context of subsurface semiconductor integrated circuit imaging. We demonstrate that the collection of forbidden light allows for sub-diffraction spatial resolution and substantial enhancement of photon collection efficiency albeit inducing wave-front discontinuities and aberrations.
- Open Access
- 21 March 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (6) , 7320-7329
Effect of vector asymmetry of radially polarized beams in solid immersion microscopy.
We theoretically and experimentally investigate the effect of imperfect vector symmetry on radially polarized beams focused by an aplanatic solid immersion lens at a numerical aperture of 3.3. We experimentally achieve circularly symmetric focused spot with a full-width-half-maximum of ~λ0/5.7 at λ0 = 1310nm, free-space wavelength. The tight spatial confinement and overall circular symmetry of the focused radially polarized beam are found to be sensitive to perturbations of its cylindrical polarization symmetry. The addition of a liquid crystal based variable retarder to the optical path can effectively ensure the vector symmetry and achieve circularly symmetric focused spots at such high numerical aperture conditions.
- 21 March 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (6) , 7320-7329
Open AccessEffect of vector asymmetry of radially polarized beams in solid immersion microscopy.
We theoretically and experimentally investigate the effect of imperfect vector symmetry on radially polarized beams focused by an aplanatic solid immersion lens at a numerical aperture of 3.3. We experimentally achieve circularly symmetric focused spot with a full-width-half-maximum of ~λ0/5.7 at λ0 = 1310nm, free-space wavelength. The tight spatial confinement and overall circular symmetry of the focused radially polarized beam are found to be sensitive to perturbations of its cylindrical polarization symmetry. The addition of a liquid crystal based variable retarder to the optical path can effectively ensure the vector symmetry and achieve circularly symmetric focused spots at such high numerical aperture conditions.
- 8 November 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (23) , 28189-28197
Aberration compensation in aplanatic solid immersion lens microscopy
The imaging quality of an aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the samples have thicknesses that are more than a few micrometers thicker or thinner than the design thickness. Aberration due to the sample thickness error is modeled and compared with measurements obtained in a high numerical aperture (NA ~3.5) microscope. A technique to recover near-ideal imaging quality by compensating aberrations using a MEMS deformable mirror is described and demonstrated.
- 8 November 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (23) , 28189-28197
Aberration compensation in aplanatic solid immersion lens microscopy
The imaging quality of an aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the samples have thicknesses that are more than a few micrometers thicker or thinner than the design thickness. Aberration due to the sample thickness error is modeled and compared with measurements obtained in a high numerical aperture (NA ~3.5) microscope. A technique to recover near-ideal imaging quality by compensating aberrations using a MEMS deformable mirror is described and demonstrated.
- 22 March 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 85 (11)
Lattice-corrected strain-induced vector potentials in graphene
The electronic implications of strain in graphene can be captured at low energies by means of pseudovector potentials which can give rise to pseudomagnetic fields. These strain-induced vector potentials arise from the local perturbation to the electronic hopping amplitudes in a tight-binding framework. Here we complete the standard description of the strain-induced vector potential, which accounts only for the hopping perturbation, with the explicit inclusion of the lattice deformations or, equivalently, the deformation of the Brillouin zone. These corrections are linear in strain and are different at each of the strained, inequivalent Dirac points, and hence are equally necessary to identify the precise magnitude of the vector potential. This effect can be relevant in scenarios of inhomogeneous strain profiles, where electronic motion depends on the amount of overlap among the local Fermi surfaces. In particular, it affects the pseudomagnetic field distribution induced by inhomogeneous strain configurations, and can lead to new opportunities in tailoring the optimal strain fields for certain desired functionalities.
- 22 March 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 85 (11)
Lattice-corrected strain-induced vector potentials in graphene
The electronic implications of strain in graphene can be captured at low energies by means of pseudovector potentials which can give rise to pseudomagnetic fields. These strain-induced vector potentials arise from the local perturbation to the electronic hopping amplitudes in a tight-binding framework. Here we complete the standard description of the strain-induced vector potential, which accounts only for the hopping perturbation, with the explicit inclusion of the lattice deformations or, equivalently, the deformation of the Brillouin zone. These corrections are linear in strain and are different at each of the strained, inequivalent Dirac points, and hence are equally necessary to identify the precise magnitude of the vector potential. This effect can be relevant in scenarios of inhomogeneous strain profiles, where electronic motion depends on the amount of overlap among the local Fermi surfaces. In particular, it affects the pseudomagnetic field distribution induced by inhomogeneous strain configurations, and can lead to new opportunities in tailoring the optimal strain fields for certain desired functionalities.
- 3 January 2012
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 4 (3) , 715-726
Single nanoparticle detectors for biological applications
Nanoparticle research has become increasingly important in the context of bioscience and biotechnology. Practical use of nanoparticles in biology has significantly advanced our understanding about biological processes in the nanoscale as well as led to many novel diagnostic and therapeutic applications. Besides, synthetic and natural nanoparticles are of concern for their potential adverse effect on human health. Development of novel detection and characterization tools for nanoparticles will impact a broad range of disciplines in biological research from nanomedicine to nanotoxicology. In this article, we discuss the recent progress and future directions in the area of single nanoparticle detectors with an emphasis on their biological applications. A brief critical overview of electrical and mechanical detection techniques is given and a more in-depth discussion of label-free optical detection techniques is presented.
- 3 January 2012
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 4 (3) , 715-726
Single nanoparticle detectors for biological applications
Nanoparticle research has become increasingly important in the context of bioscience and biotechnology. Practical use of nanoparticles in biology has significantly advanced our understanding about biological processes in the nanoscale as well as led to many novel diagnostic and therapeutic applications. Besides, synthetic and natural nanoparticles are of concern for their potential adverse effect on human health. Development of novel detection and characterization tools for nanoparticles will impact a broad range of disciplines in biological research from nanomedicine to nanotoxicology. In this article, we discuss the recent progress and future directions in the area of single nanoparticle detectors with an emphasis on their biological applications. A brief critical overview of electrical and mechanical detection techniques is given and a more in-depth discussion of label-free optical detection techniques is presented.
- 30 November 2011
- Published by Elsevier in Microelectronics Reliability
- Vol. 51 (9-11) , 1637-1639
Chromatic and spherical aberration correction for silicon aplanatic solid immersion lens for fault isolation and photon emission microscopy of integrated circuits
- 30 November 2011
- Published by Elsevier in Microelectronics Reliability
- Vol. 51 (9-11) , 1637-1639
Chromatic and spherical aberration correction for silicon aplanatic solid immersion lens for fault isolation and photon emission microscopy of integrated circuits
- Open Access
- 5 August 2011
- Published by American Physical Society (APS) in Physical Review B
- Vol. 84 (7) , 075428
Electron-phonon coupling ofmode and assignment of a combination mode in carbon nanotubesWe measure the electron-phonon (e-ph) coupling matrix elements of the band in semiconducting carbon nanotubes (CNTs) in comparison to the radial breathing mode (RBM). The experimental result for the mode [Γ-point longitudinal optical (LO) phonon] at the transition suggests an e-ph coupling strength of approximately 30 meV or 12.5 eV/Å, which is within the expected range of 23 meV to 83 meV for a 1-nm-diameter CNT. This coupling (as the square of the matrix elements) for the mode is an order of magnitude higher than that of the RBM and other measured phonon modes. In addition we assign a Raman feature observed around 1700 cm to be the combination mode of a low energy (∼400 cm) and a high energy (∼1300 cm) zone-boundary phonon. Both the phonon energies and phonon dispersions of those modes support the assignment.- 5 August 2011
- Published by American Physical Society (APS) in Physical Review B
- Vol. 84 (7) , 075428
Open AccessElectron-phonon coupling ofmode and assignment of a combination mode in carbon nanotubesWe measure the electron-phonon (e-ph) coupling matrix elements of the band in semiconducting carbon nanotubes (CNTs) in comparison to the radial breathing mode (RBM). The experimental result for the mode [Γ-point longitudinal optical (LO) phonon] at the transition suggests an e-ph coupling strength of approximately 30 meV or 12.5 eV/Å, which is within the expected range of 23 meV to 83 meV for a 1-nm-diameter CNT. This coupling (as the square of the matrix elements) for the mode is an order of magnitude higher than that of the RBM and other measured phonon modes. In addition we assign a Raman feature observed around 1700 cm to be the combination mode of a low energy (∼400 cm) and a high energy (∼1300 cm) zone-boundary phonon. Both the phonon energies and phonon dispersions of those modes support the assignment. - 1 May 2008
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 40 (7) , 2375-2379
Scaling of exciton binding energy with external dielectric function in carbon nanotubes
- 1 May 2008
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 40 (7) , 2375-2379
Scaling of exciton binding energy with external dielectric function in carbon nanotubes
- 12 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 14 (1) , 131-139
Resonant Cavity Imaging: A Means Toward High-Throughput Label-Free Protein Detection
The resonant cavity imaging biosensor (RCIB) is an optical technique for detecting molecular binding interactions label free at many locations in parallel that employs an optical resonant cavity for high sensitivity. Near-infrared light centered at 1512.5 nm couples resonantly through a Fabry-Perot cavity constructed from dielectric reflectors (Si/SiO2), one of which serves as the binding surface. As the wavelength is swept using a tunable laser, a near-infrared digital camera monitors cavity transmittance at each pixel. A wavelength shift in the local resonant response of the optical cavity indicates binding. Positioning the sensing surface with respect to the standing wave pattern of the electric field within the cavity controls the sensitivity with which the presence of bound molecules is detected. Transmitted intensity at thousands of pixel locations is recorded simultaneously in a 10 s, 5 nm scan. An initial proof-of-principle setup has been constructed. A test sample was fabricated with 25,100-mum wide square features, each with a different density of 1-mum square depressions etched 12 nm into the SiO2 surface. The average depth of each etched region was found with 0.05 nm rms precision. In a second test, avidin, bound selectively to biotin conjugated bovine serum albumin, was detected.
- 12 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 14 (1) , 131-139
Resonant Cavity Imaging: A Means Toward High-Throughput Label-Free Protein Detection
The resonant cavity imaging biosensor (RCIB) is an optical technique for detecting molecular binding interactions label free at many locations in parallel that employs an optical resonant cavity for high sensitivity. Near-infrared light centered at 1512.5 nm couples resonantly through a Fabry-Perot cavity constructed from dielectric reflectors (Si/SiO2), one of which serves as the binding surface. As the wavelength is swept using a tunable laser, a near-infrared digital camera monitors cavity transmittance at each pixel. A wavelength shift in the local resonant response of the optical cavity indicates binding. Positioning the sensing surface with respect to the standing wave pattern of the electric field within the cavity controls the sensitivity with which the presence of bound molecules is detected. Transmitted intensity at thousands of pixel locations is recorded simultaneously in a 10 s, 5 nm scan. An initial proof-of-principle setup has been constructed. A test sample was fabricated with 25,100-mum wide square features, each with a different density of 1-mum square depressions etched 12 nm into the SiO2 surface. The average depth of each etched region was found with 0.05 nm rms precision. In a second test, avidin, bound selectively to biotin conjugated bovine serum albumin, was detected.