Jonathan Clive Lake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan Clive Lake has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Gerry Clare
Moorfields Eye Hospital NHS Foundation Trust; 162 City Road London UK
2 shared publicationsGustavo Jm Porfírio
Centro de Estudos de Saúde Baseada em Evidências e Avaliação Tecnológica em Saúde; Cochrane Brazil; Rua Borges Lagoa, 564 cj 63 São Paulo SP Brazil 04038-000
2 shared publicationsGustavo Victor
Av. Republica do Libano 1034 São Paulo Brazil
2 shared publications- André Lins de Medeiros1 shared publication
- Antonio Francisco Pimenta Motta
Department of Ophthalmology,Renato Ambrosio Research Center CEORA, Brazil
1 shared publication Armando Crema
From the Department of Cataract (Lake, Boianovsky), Brasilia Vision Hospital, and the Pacini Hospital Oftalmológico (de Faria Pacini), Brasilia, and the Walsh & Crema Clinica e Microcirurgia Ocular (Crema), Rio de Janeiro, Brazil
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 84
Objective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses
This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus [...] ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus
- 26 November 2025
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 84
Open AccessObjective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses
This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus [...] ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus
- 17 December 2019
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2019 (12) , CD012801
Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification
Background Cataract is the leading cause of blindness in the world, and clinically significant astigmatism may affect up to approximately 20% of people undergoing cataract surgery. Pre‐existing astigmatism in people undergoing cataract surgery may be treated, among other techniques, by placing corneal incisions near the limbus (limbal relaxing incisions or LRIs) or by toric intraocular lens (IOLs) specially designed to reduce or treat the effect of corneal astigmatism on unaided visual acuity. Objectives To assess the effects of toric IOLs compared with LRIs in the management of astigmatism during phacoemulsification cataract surgery. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register; 2019, Issue 9); Ovid MEDLINE; Ovid Embase and four other databases. The date of the search was 27 September 2019. Selection criteria We included randomised controlled trials (RCTs) comparing toric IOLs with LRIs during phacoemulsification cataract surgery. Data collection and analysis We used standard methods expected by Cochrane. We graded the certainty of the evidence using GRADE. Our primary outcome was the proportion of participants with postoperative residual refractive astigmatism of less than 0.50 dioptres (D) six months or more after surgery. We also collected data on mean residual refractive astigmatism. Secondary outcomes included: uncorrected distance visual acuity, vision‐related quality of life, spectacle independence and adverse effects including postoperative lens rotation requiring re‐alignment. To supplement the main systematic review assessing the effects of toric IOLs compared with LRIs in the management of astigmatism during phacoemulsification cataract surgery, we sought to identify economic evaluations on the subject. Main results We identified 10 relevant studies including 517 people (626 eyes). These studies took place in China (three studies), UK (three), Brazil (one), India (one), Italy (one) and Spain (one). The median age of participants was 71 years. The level of corneal astigmatism specified in the inclusion criteria of these studies ranged from 0.75 D to 3 D. A variety of toric IOLs were used in these studies, in all but one study, these were monofocal. Studies used three different nomograms to determine the size and placement of the LRI. Two studies did not specify this. None of the studies were at low risk of bias in all domains, but two studies were at low risk of bias in all domains except selective outcome reporting, which was unclear. The remaining studies were at a mixture of low, unclear or high risk of bias. People receiving toric IOLs were probably more likely to achieve a postoperative residual refractive astigmatism of less than 0.5 D six months or more after surgery (risk ratio (RR) 1.40, 95% confidence interval (CI) 1.10 to 1.78; 5 RCTs, 262 eyes). We judged this to be moderate‐certainty evidence, downgrading for risk of bias. In the included studies, approximately 500 eyes per 1000 achieved postoperative astigmatism less than 0.5 D in the LRI group compared with 700 per 1000 in the toric IOLs group. There was a small difference in residual astigmatism between the two groups, favouring toric IOLs (mean difference (MD) –0.32 D, 95% CI –0.48 to –0.15 D; 10 RCTs, 620 eyes). Although all studies favoured toric IOLs, the results of individual studies were inconsistent (range of effects –0.02 D to –0.71 D; I² = 89%). We considered this to be low‐certainty evidence, downgrading for risk of bias and inconsistency. People receiving a toric IOL probably have a small improvement in visual acuity at six months or more after surgery compared to people receiving LRI, but the difference is small and probably clinically insignificant (MD –0.04 logMAR, 95% CI –0.07 to –0.02; 8 RCTs, 474 eyes; moderate‐certainty evidence). Low‐certainty evidence from one study of 40 people suggested little difference in vision‐related quality of life measured using the Visual Function Index (VF‐14) (MD –3.01, 95% CI –8.56 to 2.54). Two studies reported spectacle independence and suggested that people receiving toric IOLs may be more likely to be spectacle independent (RR 1.56, 95% CI 1.14 to 2.15; 100 people; low‐certainty evidence). There were no cases of lens rotation requiring surgery (very low‐certainty evidence). Five studies (320 eyes) commented on a range of other adverse effects including corneal oedema, endophthalmitis and corneal ectasia. All these studies reported that there were no adverse events with the exception of one study (40 eyes) where one participant in the LRI group had a central de‐epithelisation which recovered over 10 days. We found no economic studies that compared toric IOLs with LRIs. Authors' conclusions Toric IOLs probably provide a higher chance of achieving astigmatism within 0.5 D after cataract surgery compared with LRIs. There may be a small mean difference in postoperative astigmatism, favouring toric IOLs, but this difference is likely to be clinically unimportant. There was no evidence of an important difference in postoperative visual acuity or quality of life between the techniques. Evidence on adverse effects was uncertain. The apparent shortage of relevant economic evaluations indicates that economic evidence regarding the costs and consequence of these two procedures is currently lacking.
- 17 December 2019
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2019 (12) , CD012801
Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification
Background Cataract is the leading cause of blindness in the world, and clinically significant astigmatism may affect up to approximately 20% of people undergoing cataract surgery. Pre‐existing astigmatism in people undergoing cataract surgery may be treated, among other techniques, by placing corneal incisions near the limbus (limbal relaxing incisions or LRIs) or by toric intraocular lens (IOLs) specially designed to reduce or treat the effect of corneal astigmatism on unaided visual acuity. Objectives To assess the effects of toric IOLs compared with LRIs in the management of astigmatism during phacoemulsification cataract surgery. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register; 2019, Issue 9); Ovid MEDLINE; Ovid Embase and four other databases. The date of the search was 27 September 2019. Selection criteria We included randomised controlled trials (RCTs) comparing toric IOLs with LRIs during phacoemulsification cataract surgery. Data collection and analysis We used standard methods expected by Cochrane. We graded the certainty of the evidence using GRADE. Our primary outcome was the proportion of participants with postoperative residual refractive astigmatism of less than 0.50 dioptres (D) six months or more after surgery. We also collected data on mean residual refractive astigmatism. Secondary outcomes included: uncorrected distance visual acuity, vision‐related quality of life, spectacle independence and adverse effects including postoperative lens rotation requiring re‐alignment. To supplement the main systematic review assessing the effects of toric IOLs compared with LRIs in the management of astigmatism during phacoemulsification cataract surgery, we sought to identify economic evaluations on the subject. Main results We identified 10 relevant studies including 517 people (626 eyes). These studies took place in China (three studies), UK (three), Brazil (one), India (one), Italy (one) and Spain (one). The median age of participants was 71 years. The level of corneal astigmatism specified in the inclusion criteria of these studies ranged from 0.75 D to 3 D. A variety of toric IOLs were used in these studies, in all but one study, these were monofocal. Studies used three different nomograms to determine the size and placement of the LRI. Two studies did not specify this. None of the studies were at low risk of bias in all domains, but two studies were at low risk of bias in all domains except selective outcome reporting, which was unclear. The remaining studies were at a mixture of low, unclear or high risk of bias. People receiving toric IOLs were probably more likely to achieve a postoperative residual refractive astigmatism of less than 0.5 D six months or more after surgery (risk ratio (RR) 1.40, 95% confidence interval (CI) 1.10 to 1.78; 5 RCTs, 262 eyes). We judged this to be moderate‐certainty evidence, downgrading for risk of bias. In the included studies, approximately 500 eyes per 1000 achieved postoperative astigmatism less than 0.5 D in the LRI group compared with 700 per 1000 in the toric IOLs group. There was a small difference in residual astigmatism between the two groups, favouring toric IOLs (mean difference (MD) –0.32 D, 95% CI –0.48 to –0.15 D; 10 RCTs, 620 eyes). Although all studies favoured toric IOLs, the results of individual studies were inconsistent (range of effects –0.02 D to –0.71 D; I² = 89%). We considered this to be low‐certainty evidence, downgrading for risk of bias and inconsistency. People receiving a toric IOL probably have a small improvement in visual acuity at six months or more after surgery compared to people receiving LRI, but the difference is small and probably clinically insignificant (MD –0.04 logMAR, 95% CI –0.07 to –0.02; 8 RCTs, 474 eyes; moderate‐certainty evidence). Low‐certainty evidence from one study of 40 people suggested little difference in vision‐related quality of life measured using the Visual Function Index (VF‐14) (MD –3.01, 95% CI –8.56 to 2.54). Two studies reported spectacle independence and suggested that people receiving toric IOLs may be more likely to be spectacle independent (RR 1.56, 95% CI 1.14 to 2.15; 100 people; low‐certainty evidence). There were no cases of lens rotation requiring surgery (very low‐certainty evidence). Five studies (320 eyes) commented on a range of other adverse effects including corneal oedema, endophthalmitis and corneal ectasia. All these studies reported that there were no adverse events with the exception of one study (40 eyes) where one participant in the LRI group had a central de‐epithelisation which recovered over 10 days. We found no economic studies that compared toric IOLs with LRIs. Authors' conclusions Toric IOLs probably provide a higher chance of achieving astigmatism within 0.5 D after cataract surgery compared with LRIs. There may be a small mean difference in postoperative astigmatism, favouring toric IOLs, but this difference is likely to be clinically unimportant. There was no evidence of an important difference in postoperative visual acuity or quality of life between the techniques. Evidence on adverse effects was uncertain. The apparent shortage of relevant economic evaluations indicates that economic evidence regarding the costs and consequence of these two procedures is currently lacking.
- 14 June 2018
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (6) , 677-679
Second-wave hydrodissection for aspiration of cortical remains after femtosecond laser–assisted cataract surgery
We describe the technique of second-wave hydrodissection (the first wave being the initial cortical cleaving hydrodissection) performed after the removal of the cataract nucleus in femtosecond laser–assisted cataract surgery. After femtosecond laser application, the cortex is typically found adhered to the anterior capsule. Under high magnification, a steady stream of a balanced salt solution is directed toward the anterior capsule using a hydrodissection cannula. Full cleavage of the remaining cortex is observed by noting the appearance of a dark inner circle by the capsulotomy edge once the balanced salt solution wave has separated the cortex from the capsule. Irrigation/aspiration (I/A) of the cortical remains after the second wave is faster than I/A without this step in femtosecond laser–assisted cataract surgery.
- 14 June 2018
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (6) , 677-679
Second-wave hydrodissection for aspiration of cortical remains after femtosecond laser–assisted cataract surgery
We describe the technique of second-wave hydrodissection (the first wave being the initial cortical cleaving hydrodissection) performed after the removal of the cataract nucleus in femtosecond laser–assisted cataract surgery. After femtosecond laser application, the cortex is typically found adhered to the anterior capsule. Under high magnification, a steady stream of a balanced salt solution is directed toward the anterior capsule using a hydrodissection cannula. Full cleavage of the remaining cortex is observed by noting the appearance of a dark inner circle by the capsulotomy edge once the balanced salt solution wave has separated the cortex from the capsule. Irrigation/aspiration (I/A) of the cortical remains after the second wave is faster than I/A without this step in femtosecond laser–assisted cataract surgery.
- 20 September 2017
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2017 (9)
Limbal relaxing incisions versus toric intraocular lens for corneal astigmatism after phacoemulsification
- 20 September 2017
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2017 (9)
Limbal relaxing incisions versus toric intraocular lens for corneal astigmatism after phacoemulsification
- Open Access
- 1 August 2004
- Published by FapUNIFESP (SciELO) in Arquivos Brasileiros de Oftalmologia
- Vol. 67 (4) , 575-579
Efeito terapêutico da aplicação intra-ocular de ozônio em modelo experimental de endoftalmite por Staphylococcus epidermidis em coelhos
PURPOSE: To evaluate the anti-inflammatory and antimicrobial effect of intraocular ozone diluted in BSS on experimental Staphylococcus epidermidis endophthalmitis. METHODS: We injected 0.1ml of S. epidermidis colonies (10(5) colonies/ml) to produce experimental endophthalmitis in the right eyes of 17 New Zealand rabbits. Seven rabbits were assigned to a control group and received an intravitreal injection of 0.1ml BSS. Ten rabbits were treated with intravitreal injection of 0.1ml BSS-diluted ozone (2 ppm). Data were distributed according to clinical and histological findings after 24 hours, each rabbit receiving a score. Mean scores and standard deviations were compared using the two-sample t test. RESULTS: Mean clinical score for the control group was 11.14 ± 1.04. Mean clinical score for the treated group was 4.90 ± 1.29, which was significantly lower (p<0.01). Mean histological scores were, respectively, 17.00+ 0.57 and 10.20 ±1.30 for the control group and the treated group. The histological scores were significantly lower for the treated group (p<0.01). All cultures in both control and ozone groups were positive after 24 hours of experiment. CONCLUSION: Treatment with diluted ozone significantly reduced the inflammatory reaction in our model of experimental endophthalmitis. This probably occurred due to a decrease in bacterial content after ozone injection. It is necessary to study other ozone concentrations in different experimental models in order to determine ozone efficacy with a higher precision.OBJETIVO: Avaliar a ação antiinflamatória e antimicrobiana da injeção intravítrea de ozônio diluído em solução salina balanceada (BSS) em modelo experimental de endoftalmite por Staphylococcus epidermidis. MÉTODOS: Dezessete coelhos da raça Nova Zelândia receberam inoculação no olho direito de 0,1 ml de uma solução de 10(5) bactérias (S. epidermidis) por ml para indução de endoftalmite. Sete coelhos receberam injeção intravítrea de 0,1ml de BSS como controle e os outros dez coelhos receberam injeção intravítrea de 0,1ml de BSS com ozônio diluído a 2 ppm. Os dados foram quantificados de acordo com parâmetros clínicos e histopatológicos e computados numericamente para cada coelho após 24 horas de evolução. As médias e os desvios-padrão (DP) foram calculados e comparados por meio de teste t com duas amostras. RESULTADOS: A média da quantificação clínica dos olhos dos coelhos do grupo controle foi de 11,14 com DP de 1,04. A média clínica dos olhos tratados com ozônio foi de 4,90 com DP de 1,29. A média dos olhos tratados com ozônio foi significativamente menor do que os não tratados (P<0,01). A média da quantificação histopatológica dos olhos dos coelhos do grupo controle e do grupo tratado com ozônio foi de 17,00 (DP=0,57) e de 10,20 (DP=1,30), respectivamente. A resposta inflamatória do grupo tratado foi significativamente menor do que o não tratado (P<0,01). CONCLUSÃO: O ozônio diminuiu significativamente a reação inflamatória no modelo de endoftalmite pesquisado. Isto ocorreu possivelmente devido à redução da carga bacteriana provocado pelo ozônio. Ainda é necessário estudar vias de administração e concentrações de ozônio mais eficazes em outros modelos de infecção.Santa Casa Departamento de Oftalmologia Seção de Córnea e Doenças ExternasUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Instituto da CatarataUniversidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUNIFESP, EPM, Instituto da CatarataUNIFESP, Depto. de OftalmologiaSciEL
- 1 August 2004
- Published by FapUNIFESP (SciELO) in Arquivos Brasileiros de Oftalmologia
- Vol. 67 (4) , 575-579
Open AccessEfeito terapêutico da aplicação intra-ocular de ozônio em modelo experimental de endoftalmite por Staphylococcus epidermidis em coelhos
PURPOSE: To evaluate the anti-inflammatory and antimicrobial effect of intraocular ozone diluted in BSS on experimental Staphylococcus epidermidis endophthalmitis. METHODS: We injected 0.1ml of S. epidermidis colonies (10(5) colonies/ml) to produce experimental endophthalmitis in the right eyes of 17 New Zealand rabbits. Seven rabbits were assigned to a control group and received an intravitreal injection of 0.1ml BSS. Ten rabbits were treated with intravitreal injection of 0.1ml BSS-diluted ozone (2 ppm). Data were distributed according to clinical and histological findings after 24 hours, each rabbit receiving a score. Mean scores and standard deviations were compared using the two-sample t test. RESULTS: Mean clinical score for the control group was 11.14 ± 1.04. Mean clinical score for the treated group was 4.90 ± 1.29, which was significantly lower (p<0.01). Mean histological scores were, respectively, 17.00+ 0.57 and 10.20 ±1.30 for the control group and the treated group. The histological scores were significantly lower for the treated group (p<0.01). All cultures in both control and ozone groups were positive after 24 hours of experiment. CONCLUSION: Treatment with diluted ozone significantly reduced the inflammatory reaction in our model of experimental endophthalmitis. This probably occurred due to a decrease in bacterial content after ozone injection. It is necessary to study other ozone concentrations in different experimental models in order to determine ozone efficacy with a higher precision.OBJETIVO: Avaliar a ação antiinflamatória e antimicrobiana da injeção intravítrea de ozônio diluído em solução salina balanceada (BSS) em modelo experimental de endoftalmite por Staphylococcus epidermidis. MÉTODOS: Dezessete coelhos da raça Nova Zelândia receberam inoculação no olho direito de 0,1 ml de uma solução de 10(5) bactérias (S. epidermidis) por ml para indução de endoftalmite. Sete coelhos receberam injeção intravítrea de 0,1ml de BSS como controle e os outros dez coelhos receberam injeção intravítrea de 0,1ml de BSS com ozônio diluído a 2 ppm. Os dados foram quantificados de acordo com parâmetros clínicos e histopatológicos e computados numericamente para cada coelho após 24 horas de evolução. As médias e os desvios-padrão (DP) foram calculados e comparados por meio de teste t com duas amostras. RESULTADOS: A média da quantificação clínica dos olhos dos coelhos do grupo controle foi de 11,14 com DP de 1,04. A média clínica dos olhos tratados com ozônio foi de 4,90 com DP de 1,29. A média dos olhos tratados com ozônio foi significativamente menor do que os não tratados (P<0,01). A média da quantificação histopatológica dos olhos dos coelhos do grupo controle e do grupo tratado com ozônio foi de 17,00 (DP=0,57) e de 10,20 (DP=1,30), respectivamente. A resposta inflamatória do grupo tratado foi significativamente menor do que o não tratado (P<0,01). CONCLUSÃO: O ozônio diminuiu significativamente a reação inflamatória no modelo de endoftalmite pesquisado. Isto ocorreu possivelmente devido à redução da carga bacteriana provocado pelo ozônio. Ainda é necessário estudar vias de administração e concentrações de ozônio mais eficazes em outros modelos de infecção.Santa Casa Departamento de Oftalmologia Seção de Córnea e Doenças ExternasUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Instituto da CatarataUniversidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUNIFESP, EPM, Instituto da CatarataUNIFESP, Depto. de OftalmologiaSciEL