David W. Townsend
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David W. Townsend has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey T. Yap
Huntsman Cancer Institute, University of Utah, Salt Lake City, UT
1 shared publication - Jonathan P. J. Carney
University of Pittsburgh Medical Center
1 shared publication Nathan C Hall
1 shared publication- Osama Mawlawi
University of Texas
1 shared publication
Latest Publications
- 23 December 2008
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 36 (S1) , 15-29
Multimodality imaging: an update on PET/CT technology
Since their introduction in 2001, PET/CT systems have gained wide acceptance primarily due to their inherent ability to combine functional and structural information about the underlying disease state of the patient in a single imaging session. Their significance has also been documented with regard to their short imaging times, which minimize patient anxiety and image blurring due to patient motion. In the past seven years, PET/CT systems have replaced dedicated PET systems as the imaging modality of choice for diagnostic evaluation of oncology patients. The purpose of this article is to review the evolution of PET/CT systems and document their current status. Recent improvements in instrumentation are highlighted together with some outstanding issues that arise for specific PET/CT applications. These are followed by a description of some of the more common clinical applications of PET/CT imaging such as staging malignant disease, treatment planning, and monitoring therapy response. Finally, the future developments of PET/CT systems with regard to sensitivity, resolution, and new radiopharmaceuticals are discussed. The article concludes by presenting some issues concerning the next stage in the future of PET imaging, namely PET/MRI.
- 23 December 2008
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 36 (S1) , 15-29
Multimodality imaging: an update on PET/CT technology
Since their introduction in 2001, PET/CT systems have gained wide acceptance primarily due to their inherent ability to combine functional and structural information about the underlying disease state of the patient in a single imaging session. Their significance has also been documented with regard to their short imaging times, which minimize patient anxiety and image blurring due to patient motion. In the past seven years, PET/CT systems have replaced dedicated PET systems as the imaging modality of choice for diagnostic evaluation of oncology patients. The purpose of this article is to review the evolution of PET/CT systems and document their current status. Recent improvements in instrumentation are highlighted together with some outstanding issues that arise for specific PET/CT applications. These are followed by a description of some of the more common clinical applications of PET/CT imaging such as staging malignant disease, treatment planning, and monitoring therapy response. Finally, the future developments of PET/CT systems with regard to sensitivity, resolution, and new radiopharmaceuticals are discussed. The article concludes by presenting some issues concerning the next stage in the future of PET imaging, namely PET/MRI.
- 1 August 2008
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 29 (4) , 232-235
Combined Positron Emission Tomography–Computed Tomography: The Historical Perspective
- 1 August 2008
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 29 (4) , 232-235
Combined Positron Emission Tomography–Computed Tomography: The Historical Perspective
- Open Access
- 15 May 2008
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 49 (6) , 938-955
Dual-Modality Imaging: Combining Anatomy and Function
The extensive development of image fusion techniques over the past 20 y has shown that the fusion of images from complementary modalities offers a more complete and accurate assessment of disease than do images from a single modality. Although software techniques have been successful in fusing images of the brain from different modalities, they have achieved rather limited success for other parts of the body. The recent introduction of technology that can acquire both anatomic and functional images in a single scan has addressed many of the limitations of software fusion. The combination of CT and PET was introduced commercially in 2001, followed by CT and SPECT in 2004. Clinical adoption of PET/CT has been surprisingly rapid, and despite continuing debate, the new technology has advanced the use of clinical molecular imaging, particularly for oncology.
- 15 May 2008
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 49 (6) , 938-955
Open AccessDual-Modality Imaging: Combining Anatomy and Function
The extensive development of image fusion techniques over the past 20 y has shown that the fusion of images from complementary modalities offers a more complete and accurate assessment of disease than do images from a single modality. Although software techniques have been successful in fusing images of the brain from different modalities, they have achieved rather limited success for other parts of the body. The recent introduction of technology that can acquire both anatomic and functional images in a single scan has addressed many of the limitations of software fusion. The combination of CT and PET was introduced commercially in 2001, followed by CT and SPECT in 2004. Clinical adoption of PET/CT has been surprisingly rapid, and despite continuing debate, the new technology has advanced the use of clinical molecular imaging, particularly for oncology.
- 1 May 2008
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 38 (3) , 152-166
Positron Emission Tomography/Computed Tomography
- 1 May 2008
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 38 (3) , 152-166
Positron Emission Tomography/Computed Tomography
- 28 January 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , R1-R39
Multimodality imaging of structure and function
Historically, medical devices to image either anatomical structure or functional processes have developed along somewhat independent paths. The recognition that combining images from different modalities can nevertheless offer significant diagnostic advantages gave rise to sophisticated software techniques to coregister structure and function. Recently, alternatives to retrospective software-based fusion have become available through instrumentation that combines two imaging modalities within a single device, an approach that has since been termed hardware fusion. As a result, following their recent introduction into the clinic, combined PET/CT and SPECT/CT devices are now playing an increasingly important role in the diagnosis and staging of human disease. Recently, although limited to the brain, the first clinical MR scanner with a PET insert, a technically-challenging design, has been undergoing evaluation. This review will follow the development of multimodality instrumentation for clinical use from conception to present-day technology and assess the status and future potential for such devices.
- 28 January 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , R1-R39
Multimodality imaging of structure and function
Historically, medical devices to image either anatomical structure or functional processes have developed along somewhat independent paths. The recognition that combining images from different modalities can nevertheless offer significant diagnostic advantages gave rise to sophisticated software techniques to coregister structure and function. Recently, alternatives to retrospective software-based fusion have become available through instrumentation that combines two imaging modalities within a single device, an approach that has since been termed hardware fusion. As a result, following their recent introduction into the clinic, combined PET/CT and SPECT/CT devices are now playing an increasingly important role in the diagnosis and staging of human disease. Recently, although limited to the brain, the first clinical MR scanner with a PET insert, a technically-challenging design, has been undergoing evaluation. This review will follow the development of multimodality instrumentation for clinical use from conception to present-day technology and assess the status and future potential for such devices.
- 1 October 2004
- Published by Elsevier in Molecular Imaging and Biology
- Vol. 6 (5) , 275-290
From 3-D positron emission tomography to 3-D positron emission tomography/computed tomography: what did we learn?
- 1 October 2004
- Published by Elsevier in Molecular Imaging and Biology
- Vol. 6 (5) , 275-290
From 3-D positron emission tomography to 3-D positron emission tomography/computed tomography: what did we learn?
- 1 January 2004
- p. 4S-14S
PET/CT today and tomorrow.
Accurate anatomic localization of functional abnormalities seen with PET is known to be problematic. Even though nonspecific tracers such as 18F-FDG visualize certain normal anatomic structures, the spatial resolution is generally inadequate for localization of pathology. Combining PET with a high-resolution anatomic imaging modality such as CT can resolve the localization issue, as long as the images from the two modalities are accurately coregistered. However, software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. Acquiring both CT and PET images in the same scanner obviates the need for software registration and routinely provides accurately aligned images of anatomy and function in a single scan. A CT scanner positioned in tandem with a PET scanner and with a common patient couch and operating console has recently been explored as a solution to anatomic and functional image registration. Axial translation of the couch between the two modalities enables both CT and PET data to be acquired during a single imaging session. In addition, the CT images can be used to generate noiseless attenuation correction factors for the PET emission data. By minimizing patient movement between the CT and PET scans, and after accounting for the axial separation of the two modalities, accurately registered anatomic and functional images can be obtained. Since the introduction of the first PET/CT prototype a little over 5 years ago, several thousand cancer patients have been scanned on combined PET/CT devices. In the past 3 years, a number of commercial designs have become available featuring multidetector spiral CT scanners and high-performance PET devices. Initial experience has demonstrated an increased level of accuracy and confidence in the interpretation of the combined study compared with separate readings, particularly in the ability to distinguish pathology from normal physiologic uptake and to precisely localize abnormal foci. Combined PET/CT scanners represent an important evolution in technology that is helping to bring molecular imaging to the forefront in cancer diagnosis, staging, and therapy monitoring.
- 1 January 2004
- p. 4S-14S
PET/CT today and tomorrow.
Accurate anatomic localization of functional abnormalities seen with PET is known to be problematic. Even though nonspecific tracers such as 18F-FDG visualize certain normal anatomic structures, the spatial resolution is generally inadequate for localization of pathology. Combining PET with a high-resolution anatomic imaging modality such as CT can resolve the localization issue, as long as the images from the two modalities are accurately coregistered. However, software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. Acquiring both CT and PET images in the same scanner obviates the need for software registration and routinely provides accurately aligned images of anatomy and function in a single scan. A CT scanner positioned in tandem with a PET scanner and with a common patient couch and operating console has recently been explored as a solution to anatomic and functional image registration. Axial translation of the couch between the two modalities enables both CT and PET data to be acquired during a single imaging session. In addition, the CT images can be used to generate noiseless attenuation correction factors for the PET emission data. By minimizing patient movement between the CT and PET scans, and after accounting for the axial separation of the two modalities, accurately registered anatomic and functional images can be obtained. Since the introduction of the first PET/CT prototype a little over 5 years ago, several thousand cancer patients have been scanned on combined PET/CT devices. In the past 3 years, a number of commercial designs have become available featuring multidetector spiral CT scanners and high-performance PET devices. Initial experience has demonstrated an increased level of accuracy and confidence in the interpretation of the combined study compared with separate readings, particularly in the ability to distinguish pathology from normal physiologic uptake and to precisely localize abnormal foci. Combined PET/CT scanners represent an important evolution in technology that is helping to bring molecular imaging to the forefront in cancer diagnosis, staging, and therapy monitoring.
- 2 January 1999
- Published by Elsevier in Clinical Positron Imaging
- Vol. 2 (1) , 5-15
The ECAT ART Scanner for Positron Emission Tomography 1. Improvements in Performance Characteristics
- 2 January 1999
- Published by Elsevier in Clinical Positron Imaging
- Vol. 2 (1) , 5-15
The ECAT ART Scanner for Positron Emission Tomography 1. Improvements in Performance Characteristics