MGMartine Gavaret

Martine Gavaret

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martine Gavaret has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • La TEP au 18FDG dans les différents sous-types d’épilepsie du lobe temporal : validation en SEEG et valeur prédictive post-opératoire

    by E. Guedj, F. Bonini, M. Gavaret, A. Trébuchon, S. Aubert, M. Boucekine, L. Boyer, R. Carron, A. Mcgonigal, F. Bartolomei

  • Intraoperative spinal cord monitoring in children under 4 years old

    by Martine Gavaret, Sébastien Pesenti, Elie Choufani, Daniela Pennaroli, Gérard Bollini, Jean-Luc Jouve

    Purpose The purpose was to study intraoperative spinal cord monitoring (IOM) particularities and performances in children under 4 years old with congenital spinal deformities. IOM is characterized by specific difficulties due to the immaturity of sensory-motor pathways in such young patients. To the best of our knowledge, this study is the largest dedicated to IOM in this challenging population. Methods This study was retrospective and monocentric. 78 IOM in children under 4 years old were analyzed. Somatosensory evoked potentials (SSEP), neurogenic mixed evoked potentials (NMEP) and D waves were performed. Patients were classified into one of four categories with respect to IOM data and clinical outcome: true positive, false positive, true negative and false negative. Sensitivity and specificity were then calculated accordingly. Results There were 6 true positive, 3 false positive, 67 true negative and 1 false negative outcomes. One patient was characterized by unreliable baseline IOM data. IOM sensitivity was 86 %. IOM specificity was 96 %. The false negative case was monitored using SSEP alone. IOM was difficult in 10/77 cases, being unilateral because of a planned fibular graft harvest. NMEP were characterized by higher signal-to-noise ratio than SSEP. Conclusions Immaturity of sensory-motor pathways predominates in the central rather than the peripheral nervous system in young children. MEP and D waves could thus be difficult to obtain. Although non-specific to motor pathways, it could be useful to “by-pass” the brain, using NMEP. In regard to maturational particularities, IOM in children under 4 years old should be performed by experienced neurophysiologists, avoiding in these cases surgeon-guided devices.


  • Ictal Magnetic Source Imaging in Presurgical Assessment

    by Jean-Michel Badier, Christian-George Bénar, Michael Woodman, Catarina Cruto, Patrick Chauvel, Fabrice Bartolomei, Martine Gavaret

    Ictal MEG recordings constitute rare data. The objective of this study was to evaluate ictal magnetic source localization (MSI), using two algorithms: linearly constrained minimum variance (LCMV), a beamforming technique and equivalent current dipole (ECD). Ictal MSI was studied in six patients. Three of them were undergoing post-operative re-evaluation. For all patients, results were validated by the stereoelectroencephalographic (SEEG) definition of the epileptogenic zone (EZ). EZ was quantified using the epileptogenicity index (EI) method, which accounts for both the propensity of a brain area to generate rapid discharges and the time for this area to become involved in the seizure. EI values range from 0 (no epileptogenicity) to 1 (maximal epileptogenicity). Levels of concordance between ictal MSI and EZ were determined as follows: A: ictal MSI localized the site whose value EI = 1, B: MSI localized a part of the EZ (not corresponding to the maximal value of EI = 1), C: a region could be identified on ictal MSI but not on SEEG, D: a region could be identified on SEEG but not on MSI, E: different regions were localized on MSI and SEEG. Ictal MEG pattern consisted of rhythmic activities between 10 and 20 Hz for all patients. For LCMV (first maxima), levels of concordance were A (two cases), B (two cases) and E (two cases). For ECD fitted on each time point separately (location characterized by the best goodness-of-fit value), levels of concordance were A (one case), B (one case), D (three cases) and E (one case). For ECD calculated for the whole time window, levels of concordance were A (two cases) and D (four cases). Source localization methods performed on rhythmic patterns can localize the EZ as validated by SEEG. In terms of concordance, LCMV was superior to ECD. In some cases, LCMV allows extraction of several maxima that could reflect ictal dynamics. In a medial temporal lobe epilepsy case, ictal MSI indicated an area of delayed propagation and was non-contributory to the presurgical assessment.


  • Magnetic Source Imaging in Posterior Cortex Epilepsies

    by Jean-Michel Badier, Fabrice Bartolomei, Patrick Chauvel, Christian-George Bénar, Martine Gavaret

    Posterior cortex epilepsies (PCE) are characterized by less satisfying postoperative results than temporal lobe epilepsies and are thus challenging for non-invasive presurgical investigations. The objective of this study was to evaluate the performance of magnetic source imaging (MSI) in PCE, validating the results by the SEEG (stereoelectroencephalography) definition of irritative and epileptogenic zones (IZ and EZ). Fourteen PCE surgery candidates were investigated using MSI and SEEG. LCMV (Linearly Constrained Minimum Variance) and MUSIC algorithms were used. IZ was quantified using a semi-automatic detection of interictal spikes. EZ was quantified using the epileptogenicity index (EI) method that accounts for both the propensity of a brain area to generate rapid discharges and the time for this area to get involved in the seizure. EI values range from 0 (no epileptogenicity) to 1 (maximal epileptogenicity). Levels of concordance between MSI and IZ, MSI and EZ were determined as follows: A = localized on MSI and SEEG for the site of value 1 (IZ and EZ quantification), B = localized on MSI and SEEG for a part of the IZ or a structure involved in the EZ (without the maximal value 1), C = localized on MSI and not SEEG, D = localized on SEEG and not MSI, E = localized on MSI and SEEG, discordant for site. Five PCE cases were characterized by focal IZ, nine by distributed IZ between several distant brain areas. MSI allowed to determinate IZ in 4/5 focal IZ cases. In case of distributed IZ, levels of concordance were A (2 cases), B (4 cases) and D (3 cases). In most distributed cases, MSI allowed to localize only a part of the IZ. Medial temporal involvement in the IZ was frequent (9/12 cases) and not evidenced by MSI. The brain area that demonstrated the maximal value of EI was shown by MSI in four out of five (80 %) focal IZ cases, in two out of nine (22 %) distributed cases. MSI results depend on IZ characteristics. A distributed IZ organization presents difficulties for MSI and highlights the need for further methodological approaches.


  • Response to the letter by Vedran Deletis, David B. Mac Donald, Francesco Sala and Isabel Fernandez Conejero

    by M. Gavaret, J.L. Jouve, Y. Péréon, F. Accadbled, N. André-Obadia, E. Azabou, B. Blondel, G. Bollini, J. Delécrin, J.P. Farcy, et al.

  • MEG and EEG Sensitivity in a Case of Medial Occipital Epilepsy

    by Martine Gavaret, Jean-Michel Badier, Fabrice Bartolomei, Christian-Georges Bénar, Patrick Chauvel

    Interictal or ictal events in partial epilepsies may project on scalp EEG contralaterally to the side of the epileptogenic lesion. Such paradoxical lateralization can be observed in case of para-sagittal generators, and is likely due to the spatial orientation of the generator, presenting an oblique projection towards the midline. We present here a case of medial occipital epilepsy investigated using EEG, MEG and stereoelectroencephalography (SEEG). MRI displayed a focal cortical dysplasia in the superior margin of the right calcarine fissure. SEEG demonstrated bilateral medial occipital interictal spikes, with an inversion of polarity at the level of the lesion and a contralateral propagation occurring in 10 ms. Interictal iterative EEG cartographies showed a large posterior field, with a maximum contralateral to the initial generator (EEG paradoxical lateralization). With the same number of channels, interictal iterative MEG cartographies were more precise and more complex than EEG ones, indicating an onset accurately lateralized. A few milliseconds later, MEG cartographies were quadripolar, thus indicating two homotopic active generators. These MEG and EEG cartographies have been reproduced using BESA dipole simulator. Relative merits of MEG and EEG are still debated. With 151 channels, MEG source localizations indicated the right medial occipital area, as demonstrated by SEEG. An investigation with a corresponding number of EEG channels was not performed. After a down sampling to 64 sensors, this precision was lost. MEG and EEG source localization results, both with 64 channels, were quite comparable, indicating both medial occipital areas. However, a careful analysis of MEG/EEG iterative cartographies, performed with the same number of channels in both modalities, demonstrated that, in this configuration, MEG sensitivity was superior to the EEG one, allowing separating two medial occipital sources, characterized in SEEG by a time delay of 10 ms.


  • Intraoperative Monitoring in Pediatric Orthopedic Spinal Surgery

    by Martine Gavaret, Agnès Trébuchon, Sandrine Aubert, Samuel Jacopin, Benjamin Blondel, Yann Glard, Jean-Luc Jouve, Gérard Bollini

    Analysis of a prospective series of 300 consecutive cases undergoing intraoperative monitoring in pediatric orthopedic spinal surgery, of which 10% were children younger than 4 years. Determine feasibility and performance of intraoperative monitoring in children younger than 4 years. Analyze distinct physiopathologic mechanisms of relevant alerts. There are few studies in the literature concerning the intraoperative monitoring of children younger than 4 years. During childhood, the development of sensori-motor pathways is dominated by two coexisting phenomena, which have opposite effects: maturation decreasing latencies and height increasing them. We used intraoperative somatosensory-evoked potentials and neurogenic mixed evoked potentials with a flexible bipolar epidural electrode. Uniform total intravenous anesthesia was used. Values of sensitivity and specificity of the monitoring showed slight differences between patients younger than 4 years versus older patients. There was no false-negative outcome. Various tendencies were highlighted. There were more true positive alerts for secondary etiologies than for idiopathic ones, for revision spinal surgeries than for index ones, and for boys than for girls. There were no more true positive alerts for children younger than 4 years than for older patients whereas the proportion of hemivertebrae was obviously greater for the younger group. Relevant monitoring alerts were more frequent in case of kyphoscoliosis. This is highlighted in case reports. In some cases of kyphoscoliosis, during a posterior-based vertebral column resection, monitoring changes were corrected by positioning a rod that allowed correction of the position of the spine in the sagittal plane. Intraoperative spinal cord monitoring can be performed in children younger than 4 years and allows real-time assessment of spinal functional integrity.