Richard Gibbs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard Gibbs has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Lydia Hanna
Department of Surgery and Cancer, Imperial College London, London, UK; Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London, UK
3 shared publications - Chlöe Armour
National Heart and Lung Institute Imperial College London London UK
2 shared publications - Xiao Yun Xu
Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, United Kingdom
2 shared publications A. Goebells
1 shared publicationA. Haydar
1 shared publication- Alicia Levena Skervin
Colorectal Surgical Department, St Peter's Hospital, Guildford Road, Chertsey, KT16 0PZ, UK
1 shared publication
Latest Publications
- Open Access
- 11 August 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (1) , 61-71
A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth
Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.
- 11 August 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (1) , 61-71
Open AccessA numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth
Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.
- 15 October 2022
- Published by Springer Nature
- p. 343-349
Patient Reported Outcomes and Quality of Life following Percutaneous and Surgical Intervention for Subclavian Artery Disease
- 15 October 2022
- Published by Springer Nature
- p. 343-349
Patient Reported Outcomes and Quality of Life following Percutaneous and Surgical Intervention for Subclavian Artery Disease
- Open Access
- 3 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (6) , 1317
The Haemodynamic and Pathophysiological Mechanisms of Calcific Aortic Valve Disease
The aortic valve (AoV) is the outflow valve for the left heart
- 3 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (6) , 1317
Open AccessThe Haemodynamic and Pathophysiological Mechanisms of Calcific Aortic Valve Disease
The aortic valve (AoV) is the outflow valve for the left heart
- Open Access
Brain Protection in the Endo-Management of Proximal Aortic Aneurysms
Neurological brain injury (NBI) remains the most feared complication following thoracic endovascular aortic repair (TEVAR), and can manifest as clinically overt stroke and/or more covert injury, detected only on explicit neuropsychological testing. Microembolic signals (MES) detected on transcranial Doppler (TCD) monitoring of the cerebral arteries during TEVAR and the high prevalence and incidence of new ischaemic infarcts on diffusion-weighted magnetic resonance imaging (DW-MRI) suggests procedure-related solid and gaseous cerebral microembolisation to be an important cause of NBI. Any intervention that can reduce the embolic burden during TEVAR may, therefore, help mitigate the risk of stroke and the covert impact of ischaemic infarcts to the function of the brain. This perspective article provides an understanding of the mechanism of stroke and reviews the available evidence regarding potential neuroprotective strategies that target high-risk procedural steps of TEVAR to reduce periprocedural cerebral embolisation.
Open AccessBrain Protection in the Endo-Management of Proximal Aortic Aneurysms
Neurological brain injury (NBI) remains the most feared complication following thoracic endovascular aortic repair (TEVAR), and can manifest as clinically overt stroke and/or more covert injury, detected only on explicit neuropsychological testing. Microembolic signals (MES) detected on transcranial Doppler (TCD) monitoring of the cerebral arteries during TEVAR and the high prevalence and incidence of new ischaemic infarcts on diffusion-weighted magnetic resonance imaging (DW-MRI) suggests procedure-related solid and gaseous cerebral microembolisation to be an important cause of NBI. Any intervention that can reduce the embolic burden during TEVAR may, therefore, help mitigate the risk of stroke and the covert impact of ischaemic infarcts to the function of the brain. This perspective article provides an understanding of the mechanism of stroke and reviews the available evidence regarding potential neuroprotective strategies that target high-risk procedural steps of TEVAR to reduce periprocedural cerebral embolisation.
- Open Access
- 2 January 2017
- Published by Wiley in Clinical and Translational Medicine
- Vol. 6 (1) , 1
MRI detection of endothelial cell inflammation using targeted superparamagnetic particles of iron oxide (SPIO)
Background: There is currently no clinical imaging technique available to assess the degree of inflammation associated with atherosclerotic plaques. This study aims to develop targeted superparamagnetic particles of iron oxide (SPIO) as a magnetic resonance imaging (MRI) probe for detecting inflamed endothelial cells.Methods: The in vitro study consists of the characterisation and detection of inflammatory markers on activated endothelial cells by immunocytochemistry and MRI using biotinylated anti‐P‐selectin and anti‐VCAM‐1 (vascular cell adhesion molecule 1) antibody and streptavidin conjugated SPIO.Results: Established an in vitro cellular model of endothelial inflammation induced with TNF‐α (tumor necrosis factor alpha). Inflammation of endothelial cells was confirmed with both immunocytochemistry and MRI. These results revealed both a temporal and dose dependent expression of the inflammatory markers, P‐selectin and VCAM‐1, on exposure to TNF‐α.Conclusion: This study has demonstrated the development of an in vitro model to characterise and detect inflamed endothelial cells by immunocytochemistry and MRI. This will allow the future development of contrast agents and protocols for imaging vascular inflammation in atherosclerosis. This work may form the basis for a translational study to provide clinicians with a novel tool for the in vivo assessment of atherosclerosis.
- 2 January 2017
- Published by Wiley in Clinical and Translational Medicine
- Vol. 6 (1) , 1
Open AccessMRI detection of endothelial cell inflammation using targeted superparamagnetic particles of iron oxide (SPIO)
Background: There is currently no clinical imaging technique available to assess the degree of inflammation associated with atherosclerotic plaques. This study aims to develop targeted superparamagnetic particles of iron oxide (SPIO) as a magnetic resonance imaging (MRI) probe for detecting inflamed endothelial cells.Methods: The in vitro study consists of the characterisation and detection of inflammatory markers on activated endothelial cells by immunocytochemistry and MRI using biotinylated anti‐P‐selectin and anti‐VCAM‐1 (vascular cell adhesion molecule 1) antibody and streptavidin conjugated SPIO.Results: Established an in vitro cellular model of endothelial inflammation induced with TNF‐α (tumor necrosis factor alpha). Inflammation of endothelial cells was confirmed with both immunocytochemistry and MRI. These results revealed both a temporal and dose dependent expression of the inflammatory markers, P‐selectin and VCAM‐1, on exposure to TNF‐α.Conclusion: This study has demonstrated the development of an in vitro model to characterise and detect inflamed endothelial cells by immunocytochemistry and MRI. This will allow the future development of contrast agents and protocols for imaging vascular inflammation in atherosclerosis. This work may form the basis for a translational study to provide clinicians with a novel tool for the in vivo assessment of atherosclerosis.
- Open Access
- 1 May 2016
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 2 (2) , 20150402
Modified use of thoracic and iliac branch endografts to treat an abdominal aortic aneurysm with an unusually narrow neck
Abdominal aortic aneurysms with hostile anatomy are a recognized hindrance to the continuing application of endovascular aortic interventions. Narrowed aneurysm necks pose technical difficulties, particularly in the absence of customized endografts. There are multiple suggested approaches to overcome shortened and angulated necks endovascularly; however, none of these address narrowed necks. We present a case where an endograft was used outside of its “instruction for use” by combining the thoracic and iliac branch technologies to overcome this problem. Expanding the use of commercially available endografts for aortic aneurysms with hostile anatomy could have significant practical and financial benefits.
- 1 May 2016
- Published by Oxford University Press (OUP) in BJR|case reports
- Vol. 2 (2) , 20150402
Open AccessModified use of thoracic and iliac branch endografts to treat an abdominal aortic aneurysm with an unusually narrow neck
Abdominal aortic aneurysms with hostile anatomy are a recognized hindrance to the continuing application of endovascular aortic interventions. Narrowed aneurysm necks pose technical difficulties, particularly in the absence of customized endografts. There are multiple suggested approaches to overcome shortened and angulated necks endovascularly; however, none of these address narrowed necks. We present a case where an endograft was used outside of its “instruction for use” by combining the thoracic and iliac branch technologies to overcome this problem. Expanding the use of commercially available endografts for aortic aneurysms with hostile anatomy could have significant practical and financial benefits.
- 1 May 2014
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 28 (4) , 1031.e7-1031.e10
Staged Open, Endovascular, and Hybrid Repair of Concomitant Mycotic Aneurysms
- 1 May 2014
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 28 (4) , 1031.e7-1031.e10
Staged Open, Endovascular, and Hybrid Repair of Concomitant Mycotic Aneurysms
- 1 May 2014
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 47 (5) , 462-469
Imaging of the Vulnerable Carotid Plaque: Biological Targeting of Inflammation in Atherosclerosis using Iron Oxide Particles and MRI
- 1 May 2014
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 47 (5) , 462-469
Imaging of the Vulnerable Carotid Plaque: Biological Targeting of Inflammation in Atherosclerosis using Iron Oxide Particles and MRI
- 31 December 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (6) , 1729
The Incidence of Spinal Cord Ischaemia Following Thoracic and Thoracoabdominal Aortic Endovascular Intervention
- 31 December 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (6) , 1729
The Incidence of Spinal Cord Ischaemia Following Thoracic and Thoracoabdominal Aortic Endovascular Intervention