Chlöe Armour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chlöe Armour has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Yun Xu
Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, United Kingdom
3 shared publications - Richard Gibbs
Regional Vascular Unit, St Mary’s Hospital, Imperial College Healthcare National Health Service Trust, Imperial College London, London, UK
2 shared publications A. Lawrie
National Heart and Lung Institute, Imperial College London, London, United Kingdom
1 shared publication- Alaine Berry
Medical Research Council, Laboratory of Medical Sciences Imperial College London London UK
1 shared publication - Alberto Redaelli
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
1 shared publication B. Statton
Medical Research Council, Laboratory of Medical Sciences, Imperial College London, London, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 19 October 2026
- Published by Wiley in Pulmonary Circulation
- Vol. 16 (4)
4D‐Flow MRI‐Derived Wall Shear Stress as a Non‐Invasive Biomarker for the Detection and Hemodynamic Characterization of Pulmonary Hypertension
Invasive right heart catheterization (RHC) remains the reference standard for diagnosing pulmonary hypertension (PH), but there is a pressing need for non‐invasive techniques to assess pulmonary hemodynamics. This study evaluates 4D‐flow MRI‐derived wall shear stress (WSS) for PH detection using the updated 2022 hemodynamic criteria, and the prediction of right ventriculo‐pulmonary arterial (RV‐PA) uncoupling to assess disease severity. 3D WSS was measured in the main (MPA), right (RPA), and left (LPA) pulmonary arteries in a retrospective validation cohort (41 PH patients, 23 non‐PH) and then assessed in a prospective test cohort (23 PH patients, 17 healthy controls). For methodological validation, a patient‐specific computational fluid dynamics (CFD) was performed in a subset of 16 patients from the validation cohort. RV‐PA uncoupling was assessed on the cine MRI, using RV global longitudinal strain (GLS) < −15.3% and RVSV/RVESV < 1. Both 3D peak and time‐averaged WSS were significantly reduced in PH patients compared with healthy controls. Global WSS metrics demonstrated the strongest correlations with invasive hemodynamic parameters, including mPAP ( r = −0.75, p < 0.001) and PVR ( r = −0.76, p < 0.001). ROC curve analysis identified a peak WSS cutoff of < 0.30 Pa (AUC 0.98) for PH detection, a threshold achieving 90% sensitivity and 100% specificity in the test cohort. Furthermore, a peak WSS threshold of < 0.18 Pa demonstrated excellent discriminative ability for RV‐PA uncoupling. These findings support the potential integration of WSS analysis into routine CMR protocols as a non‐invasive complement to RHC, showing promise for both diagnosis and a longitudinal biomarker for monitoring PH.
- 19 October 2026
- Published by Wiley in Pulmonary Circulation
- Vol. 16 (4)
Open Access4D‐Flow MRI‐Derived Wall Shear Stress as a Non‐Invasive Biomarker for the Detection and Hemodynamic Characterization of Pulmonary Hypertension
Invasive right heart catheterization (RHC) remains the reference standard for diagnosing pulmonary hypertension (PH), but there is a pressing need for non‐invasive techniques to assess pulmonary hemodynamics. This study evaluates 4D‐flow MRI‐derived wall shear stress (WSS) for PH detection using the updated 2022 hemodynamic criteria, and the prediction of right ventriculo‐pulmonary arterial (RV‐PA) uncoupling to assess disease severity. 3D WSS was measured in the main (MPA), right (RPA), and left (LPA) pulmonary arteries in a retrospective validation cohort (41 PH patients, 23 non‐PH) and then assessed in a prospective test cohort (23 PH patients, 17 healthy controls). For methodological validation, a patient‐specific computational fluid dynamics (CFD) was performed in a subset of 16 patients from the validation cohort. RV‐PA uncoupling was assessed on the cine MRI, using RV global longitudinal strain (GLS) < −15.3% and RVSV/RVESV < 1. Both 3D peak and time‐averaged WSS were significantly reduced in PH patients compared with healthy controls. Global WSS metrics demonstrated the strongest correlations with invasive hemodynamic parameters, including mPAP ( r = −0.75, p < 0.001) and PVR ( r = −0.76, p < 0.001). ROC curve analysis identified a peak WSS cutoff of < 0.30 Pa (AUC 0.98) for PH detection, a threshold achieving 90% sensitivity and 100% specificity in the test cohort. Furthermore, a peak WSS threshold of < 0.18 Pa demonstrated excellent discriminative ability for RV‐PA uncoupling. These findings support the potential integration of WSS analysis into routine CMR protocols as a non‐invasive complement to RHC, showing promise for both diagnosis and a longitudinal biomarker for monitoring PH.
- Open Access
- 18 June 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1585345
Patient-specific modelling of pulmonary arterial hypertension: wall shear stress correlates with disease severity
Introduction: Pulmonary arterial hypertension (PAH) requires an invasive right heart catheter (RHC) procedure for diagnosis. Patients can present with initial symptoms and interact with healthcare institutes for up to 3 years before referral for diagnosis. Thus, there is a great need to develop non-invasive tools, to better screen patients and improve early diagnosis rates.Methods: seven patients diagnosed and treated for PAH were included in this study. Patient-specific computational fluid dynamics (CFD) models were built for all patients, with all model parameters tuned using non-invasive imaging data, including CT, cardiac MR, echocardiogram, and 4D-flow MRI scans–crucially, a 3D inlet velocity profile was derived from 4D-flow MRI.Results: CFD models were quantitatively and qualitatively well matched with in-vivo 4D-flow hemodynamics. A linear correlation of R2 = 0.84 was found between CFD derived time-averaged wall shear stress (TAWSS) and RHC measured mean pulmonary pressure (key diagnostic value): low TAWSS correlated with high pressure.Conclusion: This study highlights TAWSS as a potential computational biomarker for PAH. The clinical use of TAWSS to diagnose and stratify PAH patients has the potential to greatly improve patient outcomes. Further work is ongoing to validate these findings in larger cohorts.
- 18 June 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1585345
Open AccessPatient-specific modelling of pulmonary arterial hypertension: wall shear stress correlates with disease severity
Introduction: Pulmonary arterial hypertension (PAH) requires an invasive right heart catheter (RHC) procedure for diagnosis. Patients can present with initial symptoms and interact with healthcare institutes for up to 3 years before referral for diagnosis. Thus, there is a great need to develop non-invasive tools, to better screen patients and improve early diagnosis rates.Methods: seven patients diagnosed and treated for PAH were included in this study. Patient-specific computational fluid dynamics (CFD) models were built for all patients, with all model parameters tuned using non-invasive imaging data, including CT, cardiac MR, echocardiogram, and 4D-flow MRI scans–crucially, a 3D inlet velocity profile was derived from 4D-flow MRI.Results: CFD models were quantitatively and qualitatively well matched with in-vivo 4D-flow hemodynamics. A linear correlation of R2 = 0.84 was found between CFD derived time-averaged wall shear stress (TAWSS) and RHC measured mean pulmonary pressure (key diagnostic value): low TAWSS correlated with high pressure.Conclusion: This study highlights TAWSS as a potential computational biomarker for PAH. The clinical use of TAWSS to diagnose and stratify PAH patients has the potential to greatly improve patient outcomes. Further work is ongoing to validate these findings in larger cohorts.
- Open Access
- 11 August 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (1) , 61-71
A numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth
Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.
- 11 August 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (1) , 61-71
Open AccessA numerical study of the effect of thrombus breakdown on predicted thrombus formation and growth
Thrombosis is a complex biological process which involves many biochemical reactions and is influenced by blood flow. Various computational models have been developed to simulate natural thrombosis in diseases such as aortic dissection (AD), and device-induced thrombosis in blood-contacting biomedical devices. While most hemodynamics-based models consider the role of low shear stress in the initiation and growth of thrombus, they often ignore the effect of thrombus breakdown induced by elevated shear stress. In this study, a new shear stress-induced thrombus breakdown function is proposed and implemented in our previously published thrombosis model. The performance of the refined model is assessed by quantitative comparison with experimental data on thrombus formation in a backward-facing step geometry, and qualitative comparison with in vivo data obtained from an AD patient. Our results show that incorporating thrombus breakdown improves accuracy in predicted thrombus volume and captures the same pattern of thrombus evolution as measured experimentally and in vivo. In the backward-facing step geometry, thrombus breakdown impedes growth over the step and downstream, allowing a stable thrombus to be reached more quickly. Moreover, the predicted thrombus volume, height and length are in better agreement with the experimental measurements compared to the original model which does not consider thrombus breakdown. In the patient-specific AD, the refined model outperforms the original model in predicting the extent and location of thrombosis. In conclusion, the effect of thrombus breakdown is not negligible and should be included in computational models of thrombosis.
- Open Access
- 7 March 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 233, 107468
Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta
- 7 March 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 233, 107468
Open AccessData-driven generation of 4D velocity profiles in the aneurysmal ascending aorta
- Open Access
- 3 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (6) , 1317
The Haemodynamic and Pathophysiological Mechanisms of Calcific Aortic Valve Disease
The aortic valve (AoV) is the outflow valve for the left heart
- 3 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (6) , 1317
Open AccessThe Haemodynamic and Pathophysiological Mechanisms of Calcific Aortic Valve Disease
The aortic valve (AoV) is the outflow valve for the left heart