LLLihui Liu

Lihui Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lihui Liu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Demand-driven dynamic control points insertion for High-fidelity and efficient curvilinear optical proximity correction.

    by Lihui Liu, Yihan Zheng, Yanqiu Li, Weichen Huang, Yang He

    Curvilinear optical proximity correction is critical for advanced technology nodes. However, conventional methods rely on uniform or static control points distribution. Such strategy neglects correction demands of different region and the influence of adjacent regions, leading to inefficient resource allocation and sub-optimal imaging fidelity. A demand-driven dynamic control point insertion framework is introduced to overcome the control points distribution inefficiency in curvilinear optical proximity correction. Our method begins with a sparse initial set of control points and iteratively identifies critical regions. By leveraging the local support property of B-spline curves, new control point is strategically inserted into critical region, while adjacent points are adjusted to shift the critical region. By bypassing redundant uniform initialization, this method achieves high-fidelity and efficient curvilinear optical proximity correction while resolving inherent resource misallocation. This paper presents a novel dynamic control points insertion framework designed to address the fundamental flaws in initial control point distribution for curvilinear mask. Simulations demonstrate proposed method’s capability to establish rational control point distributions, thereby achieving high-fidelity and efficient optical proximity correction.

  • Open Access

    Demand-driven dynamic control points insertion for High-fidelity and efficient curvilinear optical proximity correction.

    by Lihui Liu, Yihan Zheng, Yanqiu Li, Weichen Huang, Yang He

    Curvilinear optical proximity correction is critical for advanced technology nodes. However, conventional methods rely on uniform or static control points distribution. Such strategy neglects correction demands of different region and the influence of adjacent regions, leading to inefficient resource allocation and sub-optimal imaging fidelity. A demand-driven dynamic control point insertion framework is introduced to overcome the control points distribution inefficiency in curvilinear optical proximity correction. Our method begins with a sparse initial set of control points and iteratively identifies critical regions. By leveraging the local support property of B-spline curves, new control point is strategically inserted into critical region, while adjacent points are adjusted to shift the critical region. By bypassing redundant uniform initialization, this method achieves high-fidelity and efficient curvilinear optical proximity correction while resolving inherent resource misallocation. This paper presents a novel dynamic control points insertion framework designed to address the fundamental flaws in initial control point distribution for curvilinear mask. Simulations demonstrate proposed method’s capability to establish rational control point distributions, thereby achieving high-fidelity and efficient optical proximity correction.

  • Open Access

    Design of an all-facet illuminator for high NA EUV lithography exposure tool based on deep reinforcement learning

    by Tong Li, Yuqing Chen, Yanqiu Li, Lihui Liu

    Using the illuminator for high numerical aperture (NA) extreme ultraviolet (EUV) exposure tool in EUV lithography can lead to support volume production of sub-2 nm logic nodes and leading-edge DRAM nodes. However, the typical design method of the illuminator has issues with the transmission owing to the limitation of optical structure that cannot further reduce process parameter k1, and uniformity due to the restriction of matching method that can only consider one factor affecting uniformity. The all-facet illuminator can improve transmission by removing relay system. Deep reinforcement learning (RL) can improve the uniformity by considering multiple factors. In this paper, a design method of the all-facet illuminator for high NA EUV lithography exposure tool and a matching method based on deep RL for the double facets are proposed. The all-facet illuminator is designed using matrix optics, and removing relay system to achieve high transmission. The double facets is matched using the deep RL framework, which includes the policy network with improved trainability and low computational demands, and the reward function with great optimization direction and fast convergence rate, enabling to rapidly generate multiple matching results with high uniformity. An all-facet illuminator for a 0.55 NA EUV lithography exposure tool is designed by the proposed method. Simulation results indicate that the transmission is greater than 35%, and uniformity exceed 99% under multiple illumination pupil shapes.

  • Open Access

    Automatic detection technology and application of high-performance Stokes-Mueller imaging polarimeter

    by Yujie Hu, Xiang Ma, Meng Zheng, Lihui Liu, Yanqiu Li

    The Stokes-Mueller imaging polarimeter has garnered significant interest from various industries, including material characterization, chemical engineering, pharmaceuticals, biological science, and semiconductor production. The polarimeter should be capable of automatic detection to satisfy the requirements of practical applications. A graphical user interface-based automatic Stokes-Mueller imaging polarimeter detection method is suggested. The system automatically rotates the wave plate by the DC servo motor in accordance with predefined rotation angles, captures the output image, and then performs data processing such as polar decomposition, Mueller matrix solution, and calibrationgraphical user interface experimentation with picture presentation. The Stokes-Mueller imaging polarimeter automatic detection system's instrument, working principle, and software architecture are explained. The entire detection procedure is automated, which increases productivity. The automatic detection of air and biological samples demonstrated a 20% increase in work efficiency while keeping the instrument's high-resolution (NA=0.95) and high-accuracy (error≤0.24%) performance criteria.

  • Development and performance validation of an affordable and portable high-resolution darkfield polarization-sensitive multispectral imaging microscope for the assessment of radiation dermatitis and fibrosis

    by Shicheng Hao, Sisi Guo, Shuyu Chen, Hao Wang, Qian Chen, Xudong Zhou, Lihui Liu, Aijun Zhang, Hui Sun, Ruoyu Zhang, et al.

    Radiation therapy (RT) is widely used for cancer treatment but is found with side effects of radiation dermatitis and fibrosis thereby calling for timely assessment. Nevertheless, current clinical assessment methods are found to be subjective, prone to bias, and accompanied by variability. There is, therefore, an unmet clinical need to explore a new assessment technique, ideally portable and affordable, making it accessible to less developed regions too. We developed an affordable (16764 CNY) and portable high-resolution ((3.91 μm) darkfield polarization-sensitive multispectral imaging (PS-MSI) microscope. The implementation of the Monte Carlo simulation on the PS multi spectra allows the quantitative analysis of physiological parameters (i.e., blood volume fraction (BVF) and oxygen saturation of hemoglobin) at different skin layers for the dermatitis assessment. Further derivation of the degree of linear polarization (DOLP) reflects randomly distributed collagen fibers associated with fibrosis for the fibrosis assessment. PS-MSI microscope developed revealed a significant decrease (p < 0.001, analysis of variance, ANOVA) in the DOLP associated with fibrosis like scar tissue, and significant (p < 0.001, ANOVA) increases in BVF and oxygen saturation of hemoglobin accompanying artificially induced dermatitis. One-dimensional convolutional neural network implemented on the DOLP and multiple spectra achieved accuracies of 96% and 92.2%, respectively, for the classification of the artificially induced skin dermatitis and fibrosis like scar, demonstrating the potential of the affordable PS-MSI microscope developed for objective, unbiased and consistent assessment of radiation dermatitis and fibrosis in the clinics.


  • High-accuracy reconstruction of Stokes vectors via spatially modulated polarimetry using deep learning at low light field

    by Xinxin Zhang, Lihui Liu, Yanqiu Li, Tianlei Ning, Zhe Zhao

    Polarization measurement is generally performed in scenes with a low signal-to-noise ratio (SNR) such as remote sensing and biological tissue detection. The spatially modulated polarimeter can satisfy the real-time measurement requirements in low SNR scenes by establishing the mapping between photon spatial distribution and polarization information. However, accurately measuring the polarization state under low-light illumination becomes highly challenging owing to the interference of background noise. In this paper, a deep learning method is proposed and applied to the high-accuracy reconstruction of polarization information at low light field. A reinforced two-layer deep convolutional neural network is designed to respectively extract global and local features of noise in this method. Accurate photon spatial distribution can be obtained by fusing and processing these features. Experimental results illustrate the excellent accuracy achieved by the proposed method with a maximum average value of the absolute measured error below 0.04. More importantly, the proposed method is well-performed for the reconstruction of Stokes vectors at low light fields of various levels without requiring changes to the model, enhancing its practicality and simplicity.


  • Development and performance validation of a low-cost algorithms-based hyperspectral imaging system for radiodermatitis assessment

    by Shicheng Hao, Ying Xiong, Sisi Guo, Jing Gao, Xiaotong Chen, Ruoyu Zhang, Lihui Liu, Jianfeng Wang

    Whilst radiotherapy (RT) is widely used for cancer treatment, radiodermatitis caused by RT is one most common severe side effect affecting 95% cancer patients. Accurate radiodermatitis assessment and classification is essential to adopt timely treatment, management and monitoring, which all depend on reliable and objective tools for radiodermatitis grading. We therefore, in this work, reported the development and grading performance validation of a low-cost (∼2318.2 CNY) algorithms-based hyperspectral imaging (aHSI) system for radiodermatitis assessment. The low-cost aHSI system was enabled through Monte Carlo (MC) simulations conducted on multi-spectra acquired from a custom built low-cost multispectral imaging (MSI) system, deriving algorithms-based hyper-spectra with spectral resolution of 1 nm. The MSI system was based on sequentially illuminated narrow-band light-emitting diodes (LEDs) and a CMOS camera. Erythema induced artificially on healthy volunteers was measured by the aHSI system developed, with algorithms-based hyper-spectra and skin layer resolved physiological parameters (i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood, et. al.) derivation using MC simulations. The MC simulations derived BVF and the oxygen saturation of hemoglobin in blood showed significant (P < 0.001, analysis of variance: ANOVA) increase with erythema. Further 1D-convolution neural network (CNN) implemented on the algorithms-based hyper-spectra leads to an overall classification accuracy of 93.1%, suggesting the great potential of low-cost aHSI system developed for radiodermatitis assessment.


  • Open Access

    Mitigating the Impact of Mask Absorber Error on Lithographic Performance by Lithography System Holistic Optimization

    by Naiyuan Sheng, Enze Li, Yiyu Sun, Tie Li, Yanqiu Li, Pengzhi Wei, Lihui Liu

    The non-ideal mask absorber can cause an increase in critical dimension error (CDE) and decrease in process window (PW). However, the random mask absorber errors induced during mask fabricating and measuring are not considered in computational lithography. The problem cannot be neglected as the continuous scaling of lithography technology node. In this work, for the first time to our knowledge, a source, numerical aperture (NA), and process parameters co-optimization (SNPCO) method is developed to reduce the CDE induced by absorber errors and improve the PW. First, the source is represented by Zernike polynomials to balance computational burden and flexibility of source. Then a weighted cost function containing CDE and PW that incorporates the influences of absorber errors is created. Finally, a statistical optimization method is used to optimize the lithographic system parameters. Simulations of 1D mask pattern show that for the system with extreme absorber errors, the pattern errors of the proposed method are reduced by 62.1% and 58.9%, and the PWs are increased by 40.3% and 36.4%, respectively. The results illustrate that this method is effective in mitigating the CDE caused absorber errors and improving process robustness.


  • The intensity split of tightly focusing radial and azimuthal polarized vortex beam in longitudinal direction

    by Xuebing Dai, Yanqiu Li, Lihui Liu, Jianhui Li, Guodong Zhou, Yanjun Cheng, Ye Wang

    Optical vortices have been applied in many fields for their distinct properties. In this paper, we explore the focusing intensity distribution of the radially and azimuthally polarized vortex beam (VB) with varying beam waist parameter. The results reveal that low beam waist parameter is beneficial to form a super-resolution spot. In the condition of the high beam waist parameter, the focusing intensity of radially and azimuthally polarized VB along the longitudinal direction would split to multi-spots. Meanwhile, the focal plane intensity distribution become non-symmetrical as well as expansion when the beam waist parameter increase. Therefore, appropriate beam waist must be chosen for the two kind beam in actually application. Furthermore, we also investigate the focal properties affected with helical phase TC. The results reveal that the focal spot size of radially polarized VB along the longitudinal gradually increases with the order of helical phase. The peak intensity ratio of the longitudinal and transverse field of radially polarized VB holds a maximum value when helical phase order l = 0 and becomes to minimum when l =1 , then gradually increases with the order of helical phase. For the azimuthally polarized VB, when l =1 , the focal intensity would exhibit an excellent small solid spot. The results obtained in this paper are useful for application of radially and azimuthally polarized VB.

  • Determining the Charge of Vortex Beams by Focused Intensity After Polarization Modulation

    by Xuebing Dai, Yanqiu Li, Lihui Liu, Ke Liu, Meng Zheng

    Optical vortex beams (VB) carrying orbital angular momentum is of great importance in many fields. In this letter, combining a polarization modulation system and high NA lens, we propose a new method for detecting the topological charge (TC) value of VB. According to the focal field intensity distribution of VB after polarization modulation, we explore the correlation between the intensity and the TC of VB. The results reveal that the tightly focusing intensity represents a smallest solid spot when the TC value of VB equals the polarization azimuthal index. Based on this property, we can determine arbitrary states of VB by the focal intensity, especially in the case of higher charge.