BTBryan W. Tillman

Bryan W. Tillman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bryan W. Tillman has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Location Tracking of a Radio-Wave Antenna Utilizing the Radiation Pattern Recognized by Deep Network

    by Yifan Zhang, William W. Clark, Bryan Tillman, Young Jae Chun, Sung Kwon Cho

    This paper will introduce a radio frequency system to track the location of a stent designed to work inside a human artery. The stent is designed as a hemostasis aid tool for emergency situations where common surgical equipment, such as fluoroscopy systems, is not available, such as on the battlefield. In the application of interest, the stent must be guided to the correct location to achieve effective hemostasis and prevent complications. The locating approach uses the radiation pattern from the transmitter as the reference. When the transmitting frequency changes over a certain range, the measurement amplitude from a receiver depends on its relative location with respect to the transmitter. However, when the input frequency is unequal to the resonance frequency, the radiation pattern varies in an unpredictable way. To solve this problem, a deep learning model was trained to recognize variations in the radiation pattern and predict the receiver’s location as one of the classes in the reference grid. The deep learning model also reduces the impact of noise and disturbing signals, which effectively improves the system’s robustness.

  • Open Access

    High Accuracy Location Tracking for a Hemostasis Stent Achieved by the Fusion of Comprehensively Denoised Magnetic and Inertial Measurements

    by Yifan Zhang, William W. Clark, Bryan Tillman, Young Jae Chun, Stephanie Liu, Dahlia Kenawy

    This paper will introduce a location tracking system targeted on a stent when it is deployed into the human artery to achieve hemostasis. This system is proposed to be applied in emergent conditions such as treating injured soldiers on the battlefield where common surgical devices such as fluoroscopy systems are not available. The locating algorithm is based on both magnetic measurements and inertial measurements. The magnetic locating approach detects the sensor’s location in a coordinate system centered with the reference magnet source. The inertial locating approach integrates the linear acceleration and angular velocity measured by the sensor to obtain the angular and linear displacement during a time period. Measurements from all sensors are deeply fused to remove disturbances and noise that degrade the locating accuracy. The focus of this research is to identify all potential error-increasing factors and then provide solutions to correct them to enhance the location measurement reliability. Validation experiments for each improvement approach and the overall locating performance will be introduced.


  • Open Access

    A Novel Retrievable Drug Infusion Stent and Blood-Brain Barrier Portal for Antibody Therapies to the Spinal Cord

    by Jordan F. Stafford, Dahlia M. Kenawy, Jan M. Schwab, Foued Amari, Drayson Campbell, Bryan W. Tillman

    BACKGROUND AND OBJECTIVES: The blood-brain barrier (BBB) is prohibitive to intravascular drug delivery. We hypothesized that isolation of spinal cord perfusion would focus on a higher effective dose while minimizing systemic toxicity and that a histamine portal would increase BBB permeability and facilitate large molecule therapies to the spinal cord. METHODS: A dumbbell-shaped, retrievable drug infusion stentgraft (RDIS) was constructed from nitinol and polytetrafluorethylene. A porcine model under anesthesia underwent percutaneous femoral insertion of the sheathed RDIS and deployment in the lower thoracic aorta by sheath withdrawal. Antiglial fibrillary acidic protein (GFAP) tracer antibody was instilled to the outer chamber for 30 minutes +/− 80 μg of histamine, followed by stent recovery by sheath advancement, staining of spinal cord with fluorescent secondary antibody, and measurement of mean fluorescence intensity. RESULTS: Angiography confirmed center lumen distal perfusion while an integrated cannula allowed infusion to the isolated outer chamber and intercostals. Although 80 μg of histamine delivered intravenously decreased the mean arterial pressure by 22 mm Hg briefly but significantly ( P = .002), histamine infused into the RDIS outer chamber did not exhibit hypotensive effect. Animals treated using RDIS + histamine + GFAP (n = 5) revealed increased mean fluorescence intensity (mean 1074 ± 199) compared with either RDIS + GFAP without histamine (n = 5; 792 ± 223, P < .002) or simple IV infusion of GFAP + histamine (n = 5; 748 ± 172, P < .001). Although the stent perfused only 2-3 sets of intercostals, positive staining was observed well into the adjacent upper thoracic and lumbar spinal cord. CONCLUSION: An RDIS achieves focal drug delivery of antibody to the spinal cord and is retrievable after use, whereas a histamine portal facilitates passage across the BBB. The RDIS may have future utility for vascular-based delivery of antibody therapeutics or other macromolecules focused to the spinal cord for oncological, spinal cord injury and neurodegenerative disease.

  • Open Access

    Proximal stenting to resolve malperfusion before arch repair of a Marfan Type A dissection

    by Chinmayee Potti, Matthew Henn, Kristine Orion, Michael Neschis, Jovan Bozinovski, Bryan W. Tillman

  • Open Access

    A porcine model of thoracic aortic aneurysms created with a retrievable drug infusion stent graft mirrors human aneurysm pathophysiology

    by Dahlia M. Kenawy, Jordan F. Stafford, Foued Amari, Drayson Campbell, Mahmoud Abdel-Rasoul, Jennifer Leight, Youngjae Chun, Bryan W. Tillman


  • Open Access

    Gluteal and thigh compartment syndrome after open abdominal aortic aneurysm repair

    by Alim Habib, Michael R. Go, Laura Phieffer, Bryan Tillman, Mounir Haurani, Timur Sarac, Kristine C. Orion


  • Open Access

    A self calibrating, magnetic sensor approach accurately positions an aortic damage control stent in a porcine model

    by Dahlia M Kenawy, Yifan Zhang, Moataz Elsisy, Mahmoud Abdel-Rasoul, Youngjae Chun, William C Clark, Bryan W Tillman

    Objectives Non-compressible torso hemorrhage remains a high mortality injury, with difficulty mobilizing resources before exsanguination. Previous studies reported on a retrievable stent graft for damage control and morphometric algorithms for rapid placement, yet fluoroscopy is impractical for the austere environment. We hypothesized that magnetic sensors could be used to position stents relative to an external magnet placed on an anatomic landmark, whereas an electromagnet would allow self-calibration to account for environmental noise. Methods A magnetic sensor alone (MSA) and with integrated stent (MSIS) were examined in a porcine model under anesthesia. A target electromagnet was placed on the xiphoid process (position 0 cm). Sensors were placed in the aorta and measurements obtained at positions 0 cm, +4 cm, and +12 cm from the magnet and compared with fluoroscopy. Sensors were examined under conditions of tachycardia/hypertension, hypotension, vibration, and metal shrapnel to simulate environmental factors that might impact accuracy. General linear models compared mean differences between fluoroscopy and sensor readings. Results Both sensors were compatible with a 10 French catheter system and provided real-time assessment of the distance between the sensor and magnetic target in centimeters. Mean differences between fluoroscopy and both magnetic sensor readings demonstrated accuracy within ±0.5 cm for all but one condition at 0 cm and +4 cm, whereas accuracy decreased at +12 cm from the target. Using the control as a reference, there was no significant difference in mean differences between fluoroscopy and both MSA or MSIS readings at 0 cm and +4 cm for all conditions. The system retained effectiveness if the target was overshot. Conclusion Magnetic sensors achieved the highest accuracy as sensors approached the target. Oscillation of the electromagnet on and off effectively accounts for environmental noise. This approach is promising for rapid and accurate placement of damage control retrievable stent grafts when fluoroscopy is impractical. Level of evidence Not applicable.


  • Open Access

    A System to Track Stent Location in the Human Body by Fusing Magnetometer and Accelerometer Measurements

    by Yifan Zhang, William W. Clark, Bryan Tillman, Young Jae Chun, Stephanie Liu, Sung Kwon Cho

    This paper will introduce a simple locating system to track a stent when it is deployed into a human artery. The stent is proposed to achieve hemostasis for bleeding soldiers on the battlefield, where common surgical imaging equipment such as fluoroscopy systems are not available. In the application of interest, the stent must be guided to the right location to avoid serious complications. The most important features are its relative accuracy and the ease by which it may be quickly set up and used in a trauma situation. The locating approach in this paper utilizes a magnet outside the human body as the reference and a magnetometer that will be deployed inside the artery with the stent. The sensor can detect its location in a coordinate system centered with the reference magnet. In practice, the main challenge is that the locating accuracy will be deteriorated by external magnetic interference, rotation of the sensor, and random noise. These causes of error are addressed in the paper to improve the locating accuracy and repeatability under various conditions. Finally, the system’s locating performance will be validated in benchtop experiments, where the effects of the disturbance-eliminating procedures will be addressed.


  • Open Access

    A prebifurcated axillobifemoral polytetrafluoroethylene graft simplifies carotid to carotid to subclavian bypass

    by Thomas J. Perry, Timur P. Sarac, Kristine Orion, John Bozinovski, Mounir Haurani, Bryan W. Tillman