Tommi Noponen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tommi Noponen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Arno Vuori
Department of Anaesthesiology, Intensive Care, Emergency Care and Pain Medicine, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, FI-20520 Turku 52, Finland
2 shared publications - Ilkka Nissilä
Aalto University
2 shared publications - Klaus T. Olkkola
Department of Anaesthesiology and Intensive Care Medicine, University of Helsinki, Helsinki, Finland
2 shared publications - Riku Aantaa
Division of Perioperative Services, Intensive Care, Emergency Care and Pain Medicine, University of Turku, Turku, Finland
2 shared publications - Waltteri Siirala
Department of Anaesthesiology, Intensive Care, Emergency Care and Pain Medicine, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, FI-20520 Turku 52, Finland
2 shared publications - Anna Kaisanlahti
Biocenter Oulu, University of Oulu, Oulu, Finland
1 shared publication
Latest Publications
- Open Access
- 6 September 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (17) , 9623
Role of Brown and Beige Adipose Tissues in Seasonal Adaptation in the Raccoon Dog (Nyctereutes procyonoides)
Brown adipose tissue (BAT) expresses uncoupling protein-1 (UCP1), which enables energy to be exerted towards needed thermogenesis. Beige adipocytes are precursor cells interspersed among white adipose tissue (WAT) that possess similar UCP1 activity and capacity for thermogenesis. The raccoon dog (Nyctereutes procyonoides) is a canid species that utilizes seasonal obesity to survive periods of food shortage in climate zones with cold winters. The potential to recruit a part of the abundant WAT storages as beige adipocytes for UCP1-dependent thermogenesis was investigated in vitro by treating raccoon dog adipocytes with different browning inducing factors. In vivo positron emission tomography/computed tomography (PET/CT) imaging with the glucose analog 18F-FDG showed that BAT was not detected in the adult raccoon dog during the winter season. In addition, UCP1 expression was not changed in response to chronic treatments with browning inducing factors in adipocyte cultures. Our results demonstrated that most likely the raccoon dog endures cold weather without the induction of BAT or recruitment of beige adipocytes for heat production. Its thick fur coat, insulating fat, and muscle shivering seem to provide the adequate heat needed for surviving the winter.
- 6 September 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (17) , 9623
Open AccessRole of Brown and Beige Adipose Tissues in Seasonal Adaptation in the Raccoon Dog (Nyctereutes procyonoides)
Brown adipose tissue (BAT) expresses uncoupling protein-1 (UCP1), which enables energy to be exerted towards needed thermogenesis. Beige adipocytes are precursor cells interspersed among white adipose tissue (WAT) that possess similar UCP1 activity and capacity for thermogenesis. The raccoon dog (Nyctereutes procyonoides) is a canid species that utilizes seasonal obesity to survive periods of food shortage in climate zones with cold winters. The potential to recruit a part of the abundant WAT storages as beige adipocytes for UCP1-dependent thermogenesis was investigated in vitro by treating raccoon dog adipocytes with different browning inducing factors. In vivo positron emission tomography/computed tomography (PET/CT) imaging with the glucose analog 18F-FDG showed that BAT was not detected in the adult raccoon dog during the winter season. In addition, UCP1 expression was not changed in response to chronic treatments with browning inducing factors in adipocyte cultures. Our results demonstrated that most likely the raccoon dog endures cold weather without the induction of BAT or recruitment of beige adipocytes for heat production. Its thick fur coat, insulating fat, and muscle shivering seem to provide the adequate heat needed for surviving the winter.
- Open Access
- 24 January 2019
- Published by Springer Nature in EJNMMI Research
- Vol. 9 (1) , 6
Comparison of standardized uptake values between 99mTc-HDP SPECT/CT and 18F-NaF PET/CT in bone metastases of breast and prostate cancer
Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice. The aim of this study is to evaluate the feasibility of quantitative SPECT for measuring metastatic bone uptake in breast and prostate cancer by comparing standard uptake values (SUVs) measured with 99mTc-HDP SPECT/CT and 18F-NaF PET/CT. Twenty-six breast and 27 prostate cancer patients at high risk of bone metastases underwent both 99mTc-HDP SPECT/CT and 18F-NaF PET/CT within 14 days of each other. The SPECT and PET data were reconstructed using ordered-subset expectation-maximization algorithms achieving quantitative images. Metastatic and benign skeletal lesions visible in both data sets were identified, and their maximum, peak, and mean SUVs (SUVmax, SUVpeak, and SUVmean) were determined. SUV ratios (SUVRs) between the lesions and adjacent normal appearing bone were also calculated. Linear regression was used to evaluate the correlations between the SUVs of SPECT and PET and Bland-Altman plots to evaluate the differences between the SUVs and SUVRs of SPECT and PET. A total of 231 skeletal lesions, 129 metastatic and 102 benign, were analyzed. All three SUV measures correlated very strongly between SPECT and PET (R2 ≥ 0.80, p < 0.001) when all lesions were included, and the PET SUVs were significantly higher than SPECT SUVs (p < 0.001). The median differences were 21%, 12%, and 19% for SUVmax, SUVpeak, and SUVmean, respectively. On the other hand, the SUVRs were similar between SPECT and PET with median differences of 2%, − 9%, and 2% for SUVRmax, SUVRpeak, and SUVRmean, respectively. The strong correlation between SUVs and similar SUVRs of 99mTc-HDP SPECT/CT and 18F-NaF PET/CT demonstrate that SPECT is an applicable tool for clinical quantification of bone metabolism in osseous metastases in breast and prostate cancer patients.
- 24 January 2019
- Published by Springer Nature in EJNMMI Research
- Vol. 9 (1) , 6
Open AccessComparison of standardized uptake values between 99mTc-HDP SPECT/CT and 18F-NaF PET/CT in bone metastases of breast and prostate cancer
Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice. The aim of this study is to evaluate the feasibility of quantitative SPECT for measuring metastatic bone uptake in breast and prostate cancer by comparing standard uptake values (SUVs) measured with 99mTc-HDP SPECT/CT and 18F-NaF PET/CT. Twenty-six breast and 27 prostate cancer patients at high risk of bone metastases underwent both 99mTc-HDP SPECT/CT and 18F-NaF PET/CT within 14 days of each other. The SPECT and PET data were reconstructed using ordered-subset expectation-maximization algorithms achieving quantitative images. Metastatic and benign skeletal lesions visible in both data sets were identified, and their maximum, peak, and mean SUVs (SUVmax, SUVpeak, and SUVmean) were determined. SUV ratios (SUVRs) between the lesions and adjacent normal appearing bone were also calculated. Linear regression was used to evaluate the correlations between the SUVs of SPECT and PET and Bland-Altman plots to evaluate the differences between the SUVs and SUVRs of SPECT and PET. A total of 231 skeletal lesions, 129 metastatic and 102 benign, were analyzed. All three SUV measures correlated very strongly between SPECT and PET (R2 ≥ 0.80, p < 0.001) when all lesions were included, and the PET SUVs were significantly higher than SPECT SUVs (p < 0.001). The median differences were 21%, 12%, and 19% for SUVmax, SUVpeak, and SUVmean, respectively. On the other hand, the SUVRs were similar between SPECT and PET with median differences of 2%, − 9%, and 2% for SUVRmax, SUVRpeak, and SUVRmean, respectively. The strong correlation between SUVs and similar SUVRs of 99mTc-HDP SPECT/CT and 18F-NaF PET/CT demonstrate that SPECT is an applicable tool for clinical quantification of bone metabolism in osseous metastases in breast and prostate cancer patients.
- 30 December 2011
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 26 (1) , 37-43
Validation of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation support
The aim of this validation study was to assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo non-invasive ventilation (NIV). Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in twelve healthy volunteers. Respiratory quotient (RQ) and resting energy expenditure (REE) were then calculated from the measured VO2 and VCO2 values. During the measurement period the subjects were breathing spontaneously and ventilated using NIV. Two different sampling air flow values 40 and 80 l/min were used. The gas leakage from the measurement setup was assessed with a separate capnograph. The mean weight of the subjects was 93 kg. Their mean body mass index was 29 (range 22–40) kg/m2. There was no statistically significant difference in the measured values for VO2, VCO2, RQ and REE during NIV-supported breathing and spontaneous breathing. The change of sampling air flow had no statistically significant effect on any of the above parameters. We found that REE can be accurately measured with an indirect calorimeter also during NIV-supported breathing and the change of sampling air flow does not distort the gas exchange measurement. A higher sampling air flow in indirect calorimetry decreases the possibility for air leakages in the measurement system and increases the reliability of REE measurement.
- 30 December 2011
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 26 (1) , 37-43
Validation of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation support
The aim of this validation study was to assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo non-invasive ventilation (NIV). Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in twelve healthy volunteers. Respiratory quotient (RQ) and resting energy expenditure (REE) were then calculated from the measured VO2 and VCO2 values. During the measurement period the subjects were breathing spontaneously and ventilated using NIV. Two different sampling air flow values 40 and 80 l/min were used. The gas leakage from the measurement setup was assessed with a separate capnograph. The mean weight of the subjects was 93 kg. Their mean body mass index was 29 (range 22–40) kg/m2. There was no statistically significant difference in the measured values for VO2, VCO2, RQ and REE during NIV-supported breathing and spontaneous breathing. The change of sampling air flow had no statistically significant effect on any of the above parameters. We found that REE can be accurately measured with an indirect calorimeter also during NIV-supported breathing and the change of sampling air flow does not distort the gas exchange measurement. A higher sampling air flow in indirect calorimetry decreases the possibility for air leakages in the measurement system and increases the reliability of REE measurement.
- 30 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , 2941-2960
Effects of improper source coupling in frequency-domain near-infrared spectroscopy
Currently, there is no widely used method to assess the reliability of contact between optodes and tissue in near-infrared spectroscopy (NIRS). In this study we observe a high linear dependence (R(2) approximately 0.99) of the logarithmic modulation amplitude (ln(I(AC))), average intensity (ln(I(DC))) and phase (phi) on the source-detector distance (SDD) ranging from approximately 20 to 50 mm on human forehead measurements. The regression of phi is clearly reduced in measurements where light leakage occurs, mainly due to insufficient contact between the source optode and tissue. Utilizing this observation, a novel criterion to detect light leakage is developed. The criterion is applied to study the reliability of hemodynamic responses measured on the human forehead when breathing carbon dioxide-enriched air and during hyperventilation. The contrast of the signals is significantly lower in measurements which were adversely affected by light leakage. Furthermore, such unreliable signals at SDDs >or= 50 mm correlate significantly (for [HbO2] p < 0.01 and for [HbR] p < 0.001) better with the signals measured at SDDs < 20 mm. Using this method, poor contact between the source optode and tissue can be detected and corrected before the actual measurement, which enables us to avoid the acquisition of low contrast cortical signals.
- 30 April 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (10) , 2941-2960
Effects of improper source coupling in frequency-domain near-infrared spectroscopy
Currently, there is no widely used method to assess the reliability of contact between optodes and tissue in near-infrared spectroscopy (NIRS). In this study we observe a high linear dependence (R(2) approximately 0.99) of the logarithmic modulation amplitude (ln(I(AC))), average intensity (ln(I(DC))) and phase (phi) on the source-detector distance (SDD) ranging from approximately 20 to 50 mm on human forehead measurements. The regression of phi is clearly reduced in measurements where light leakage occurs, mainly due to insufficient contact between the source optode and tissue. Utilizing this observation, a novel criterion to detect light leakage is developed. The criterion is applied to study the reliability of hemodynamic responses measured on the human forehead when breathing carbon dioxide-enriched air and during hyperventilation. The contrast of the signals is significantly lower in measurements which were adversely affected by light leakage. Furthermore, such unreliable signals at SDDs >or= 50 mm correlate significantly (for [HbO2] p < 0.01 and for [HbR] p < 0.001) better with the signals measured at SDDs < 20 mm. Using this method, poor contact between the source optode and tissue can be detected and corrected before the actual measurement, which enables us to avoid the acquisition of low contrast cortical signals.
- Open Access
- 1 January 2010
- Published by Springer Nature in Nutrition & Metabolism
- Vol. 7 (1) , 70
Predictive equations over-estimate the resting energy expenditure in amyotrophic lateral sclerosis patients who are dependent on invasive ventilation support
Amyotrophic lateral sclerosis (ALS) is a form of degenerative motor neuron disease. At the end stage of the disease artificial feeding is often required. Nevertheless, very little is known about the energy demand of those ALS patients who are chronically dependent on tracheostomy intermittent positive pressure ventilation. The objective of our study was to clarify the resting energy expenditure (REE) in mechanically ventilated ALS patients.
- 1 January 2010
- Published by Springer Nature in Nutrition & Metabolism
- Vol. 7 (1) , 70
Open AccessPredictive equations over-estimate the resting energy expenditure in amyotrophic lateral sclerosis patients who are dependent on invasive ventilation support
Amyotrophic lateral sclerosis (ALS) is a form of degenerative motor neuron disease. At the end stage of the disease artificial feeding is often required. Nevertheless, very little is known about the energy demand of those ALS patients who are chronically dependent on tracheostomy intermittent positive pressure ventilation. The objective of our study was to clarify the resting energy expenditure (REE) in mechanically ventilated ALS patients.
- 30 July 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4955, 124-134
Near-infrared measurements of hemodynamic and oxygenation changes on the frontal cortex during breath holding, hyperventilation, and natural sleep
We have developed a frequency-domain near-infrared device suitable for physiological studies in human. In this work, a four-channel configuration of the instrument is applied to monitor hemodynamic and oxygenation changes in the frontal cortex of volunteers during different ventilation tasks. We use four different source-receiver separations (2, 3, 4, and 5 cm) and three wavelengths (760, 808, and 830 nm) to test the sensitivity of these parameters to cardiovascular and metabolic changes. Low-frequency oscillations (~ 0.02 Hz) and variations in heart rate during different ventilation tasks are investigated as well. We also study physiological changes during natural sleep using the frequency-domain instrument simultaneously with a polysomnography system containing a pulse oximeter. Our results indicate that hemodynamic and oxygenation changes in the frontal cortex during natural sleep can be detected using near-infrared measurements.
- 30 July 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4955, 124-134
Near-infrared measurements of hemodynamic and oxygenation changes on the frontal cortex during breath holding, hyperventilation, and natural sleep
We have developed a frequency-domain near-infrared device suitable for physiological studies in human. In this work, a four-channel configuration of the instrument is applied to monitor hemodynamic and oxygenation changes in the frontal cortex of volunteers during different ventilation tasks. We use four different source-receiver separations (2, 3, 4, and 5 cm) and three wavelengths (760, 808, and 830 nm) to test the sensitivity of these parameters to cardiovascular and metabolic changes. Low-frequency oscillations (~ 0.02 Hz) and variations in heart rate during different ventilation tasks are investigated as well. We also study physiological changes during natural sleep using the frequency-domain instrument simultaneously with a polysomnography system containing a pulse oximeter. Our results indicate that hemodynamic and oxygenation changes in the frontal cortex during natural sleep can be detected using near-infrared measurements.