FHFrank Häusler

Frank Häusler

*This is an algorithmically generated author record based on publicly available information.

Frank Häusler has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Longitudinal shear transmission of anchor channels into concrete—An experimental approach

    by Dustin Konertz, Georg Karl Kocur, Frank Häusler, Peter Mark

    The paper presents an innovative method to determine anchor forces in anchor channels exposed to longitudinal shear loads. The channel's load‐bearing behavior is experimentally investigated by fiber‐optic techniques recording the longitudinal strains. For the first time these recordings uncover the inner flux of forces and enable to deduce the load distribution on the anchors. Before applying on anchor channels, the devices and components as well as its application are tested on a tension rod. Altogether 200 tests on anchor channels are performed varying the types of channel and anchor, the number of anchors, the closest distance of an anchor to the loaded edge and the position of load application. The tests confirmed that all available anchors (up to five were tested) transfer forces into the concrete member. Load distribution on the anchors is not uniform but depends on the type of anchor, the position of load application, the distance between the anchors and load application and the number of anchors available. By contrast, channel type and edge distance of the front anchor have little impact.


  • Durchstanztragverhalten von Einzelfundamenten mit einer neuartigen Durchstanzbewehrung

    by Dominik Kueres, Marcus Ricker, Frank Häusler, Josef Hegger


  • Erhöhung des Durchstanzwiderstands von Flachdecken durch Verbundeinbauteile aus UHPC

    by Norbert Randl, Marcus Ricker, Frank Häusler, Stephan Steinberger

    Zur Beurteilung der möglichen Tragfähigkeitssteigerung von Flachdecken durch UHPC‐Verbundeinbauteile wurden neun Durchstanzversuche an Flachdeckenauschnitten im Bereich einer Innenstütze durchgeführt. Alle Versuchskörper waren mit Doppelkopfankern als Durchstanzbewehrung versehen. In acht Platten war zusätzlich zu den Doppelkopfankern ein Einbauteil aus faserbewehrtem UHPC vorhanden, um die Druckzone am Stützenanschnitt zu verstärken. Dabei wurden UHPC‐Einbauteile mit zwei unterschiedlichen Außendurchmessern verwendet. Weiterhin wurden einige Elemente durch die Anordnung von Fugen mehrteilig ausgeführt. Um einen nachträglichen Einbau der Doppelkopfanker zu ermöglichen, wurde ein Teil der Einbauteile zusätzlich mit Ankergassen ausgeführt. In den Versuchen mit UHPC‐Einbauteilen wurden signifikant höhere Bruchlasten erreicht als bei der Referenzplatte, die nur mit Doppelkopfankern als Durchstanzbewehrung versehen war. In den Versuchen mit den kleineren UHPC‐Einbauteilen konnte ein Durchstanzen außerhalb als Versagensursache benannt werden, wohingegen bei den größeren Einbauteilen eine deutliche Schädigung auch im Bereich des UHPC zu beobachten war.Enhancement of punching shear capacity of flat slabs by built‐in UHPC composite elementsA total of nine punching shear tests on interior column‐slab connections was performed to investigate the potential enhancement of the shear punching capacity in flat slabs. All test specimens included double‐headed studs as punching shear reinforcement. Eight slabs were additionally reinforced in the vicinity of the column by an UHPC unit. These elements were built in around the columns in the slab compression zone, replacing there the normal strength concrete (NSC). UHPC units with two different diameters were applied. Several of these elements were provided with joints and channels for the double‐headed studs. The slabs including an UHPC element reached significantly higher failure loads than the test specimens without such an element. In the slabs including the smaller UHPC units, a clear punching shear failure outside the elements was observed. In the case of the larger UHPC units, significant cracks occurred inside the elements, indicating the initiation of a failure of the UHPC.


  • Zum Durchstanzen von Flachdecken nach Eurocode 2

    by Josef Hegger, Joost C. Walraven, Frank Häusler

    Die Regelungen zur Durchstanzbemessung im Eurocode 2 basieren im Wesentlichen auf den Modellvorstellungen in Model Code 90, der die Durchstanztragfähigkeit auf die Querkrafttragfähigkeit zurückführt. Nach Versuchsauswertungen ist diese Analogie für punktgestützte Platten jedoch nicht in jedem Fall zutreffend. Insbesondere für bügelbewehrte Platten ist bei der Bemessung nach Eurocode 2 ein Sicherheitsdefizit möglich, und es erscheint eine Anpassung der Bemessungsgleichungen zwingend erforderlich. Dieser Beitrag erläutert die Sicherheitsdefizite und schlägt verbesserte Bemessungsgleichungen vor.Punching of Flat Slabs according to Eurocode 2The punching shear provisions according to Eurocode 2 are based on the design recommendations in Model Code 90 where no differentiation between shear and punching shear design is made. This approach is not fully confirmed by test results for flat slabs. In particular for flat slabs with stirrups as shear reinforcement some design provisions according to Eurocode 2 do not achieve the required safety level. Therefore adjustments to the design equations seem to be necessary. In this paper the Eurocode 2 provisions are critically reviewed and improved design regulations are proposed.


  • Zur Momentenumlagerung in Elementdecken mit Gitterträgern

    by Rüdiger Beutel, Johannes Furche, Josef Hegger, Frank Häusler