JCJack J. Curtis

Jack J. Curtis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jack J. Curtis has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 October 2003
      • Vol. 44  (5) , 569-76

    Cystic lesions of the pericardium. Review of the literature and classification.

    by J E Losanoff, B W Richman, J J Curtis, J W Jones

    Pericardial cystic lesions (PCLs) occur infrequently but are significant for their varying clinical presentation and pathological multitude. A review of the literature (including Medline and Current Contents database searches, and search of existing bibliographies) finds confusion in nomenclature and an absence of appropriate classification. A new classification system is proposed based on exo- or endophytic growth, presence of adhesions, and compression of myocardium or great vessels. A multitude of pathological entities with diverse pathogenesis, disease courses, and prognoses may present as PCLs. Detailed knowledge of lesion types and alternatives among diagnostic and therapeutic options permits a selective approach to patient management. The usefulness of a unified classification system should be evaluated in a substantial patient population, with detailed statistical analysis.


  • Postcardiotomy Centrifugal Assist: A Single Surgeon's Experience

    by Jack J. Curtis, Charlotte A. McKenney-Knox, Colette C. Wagner-Mann


  • Tracheostomy: a risk factor for mediastinitis after cardiac operation

    by Jack J Curtis, Nicole C Clark, Charlotte A McKenney, Joseph T Walls, Richard A Schmaltz, Todd L Demmy, James W Jones, William R Wilson, Colette C Wagner-Mann


    • 1 June 2000
      • Vol. 41  (3) , 387-92

    Ross procedure for complex left ventricular outflow tract obstruction.

    by W R Wilson, G E Greer, D S Durzinsky, J J Curtis

    Complex left ventricular outflow tract (LVOT) obstruction in children continues to pose a significant therapeutic challenge to cardiac surgeons. The Ross procedure, in combination with resection of subaortic stenosis or a Konno type septal incision, is an important option for these difficult patients. Recently two children aged 14 and 5 years with LVOT obstruction involving combined subaortic and valvar stenosis underwent surgical correction using the pulmonary autograft. Clinical presentation, operative technique, outcome and intermediate follow-up are detailed. One patient had resection of an isolated subaortic membrane in combination with a pulmonary autograft and the second a Ross Konno procedure. Postoperative hospital stays were without complication. Both patients were discharged at 5 days and have no significant obstruction nor semilunar valve insufficiency at 3 years' follow-up. Pulmonary autografts can be used in combination with resection of subaortic tissue or a septal incision for reconstruction of complex left ventricular outflow tract obstruction. This technique renders excellent short term valve function, relief of obstruction, avoids anticoagulation and provides potential for future growth.

  • Centrifugal pumps: description of devices and surgical techniques

    by Jack J Curtis, Joseph T Walls, Colette C Wagner-Mann, Richard A Schmaltz, Todd L Demmy, Charlotte A McKenney, Fred A Mann


    • 1 January 1999
      • Vol. 96  (1) , 14-7

    The heartmate left ventricular assist system: first successful implantation in Missouri.

    by W R Wilson, J J Curtis, T L Demmy, G E Greer, D J Voelker, H K Reddy, D Villarreal

    We report a case of the first successful implantation of the HeartMate left ventricular assist system as a bridge to heart transplant in the state of Missouri. Indications, technique of insertion, patient selection, outcomes and future applications are discussed.

  • Incidence and predictors of supraventricular dysrhythmias after pulmonary resection

    by Jack J Curtis, Brent M Parker, Charlotte A McKenney, Colette C Wagner-Mann, Joseph T Walls, Todd L Demmy, Richard A Schmaltz


    • 14 November 1997
      • Vol. 43  (5) , M414-7

    In vivo left ventricular assist induced coagulation derangements. Comparison of Sarns-3M and St. Jude Medical circuits.

    by J J Curtis, C C Wagner-Mann, F A Mann, T L Demmy, J T Walls, R A Schmaltz

    An in vitro comparison of centrifugal pumping systems manufactured by Sarns-3M and St. Jude Medical revealed a difference in blood cell derangement. The purpose of this study was to compare in vivo the effects of 96 hr of left ventricular assist (LVA) on indexes of coagulopathy, hemolysis, and complement activation. Two groups of calves (each: n = 5) were instrumented with identical left atrial to thoracic aorta centrifugal pumping circuits using either Sarns-3M or St. Jude centrifugal pumps. Laboratory evaluations were performed pre-assist and at 1, 4, 24, 48, 72, and 96 hr during LVA. Platelet counts dropped significantly by 24 hr (Sarns-3M: 28%; St. Jude: 30%); no significant change in function was noted. Activated clotting time increased slightly (p > 0.05). Prothrombin time increased at 4 and 24 hr of LVA, returning to baseline by 96 hr (p < 0.05). Activated partial thromboplastin time increased with the St. Jude device from 24 to 96 hr on LVA (p < 0.05); the increase with the Sarns-3M device never reached significance. No significant changes in lactate dehydrogenase or plasma free hemoglobin were detected. Complement fraction C5a rose by 1 hr of LVA (p < 0.05), peaking at 4 hr and returning to baseline by 96 hr with both pumps. No significant difference was detected between pump groups for any of the parameters. It was concluded that 1) 96 hr Sarns-3M and St. Jude LVA caused coagulation derangement in calves, 2) neither pump demonstrated an advantage regarding coagulation and complement parameters, 3) hemolysis observed with the Sarns-3M pump in vitro was not evidenced in vivo, and 4) in vitro evidenced centrifugal pump differences may not be realized in vivo.

    • 1 June 1996
      • Vol. 20  (6) , 670-7

    A calf model for left ventricular centrifugal mechanical assist.

    by F A Mann, C C Wagner-Mann, J J Curtis, T L Demmy, J R Turk

    The increased use of centrifugal mechanical assist (CMA) for treatment of refractory postcardiotomy cardiogenic shock highlights the need for experimental testing to improve clinical results. This report describes the preoperative conditioning, anesthetic and surgical technique, and postoperative management of a reliable calf model refined in this laboratory for in vivo subchronic (96 h) testing of CMA. Holstein bull calves (2 to 3 months old; mean body weight, 78 kg; n = 35) were instrumented for left ventricular CMA; 4 of these calves were sham-operated controls. Anesthetic recovery and postoperative restraint were accomplished in a specially designed crate to which each calf was preconditioned extensively. Younger calves were more readily conditioned and more tolerant of postoperative restraint than older calves. One calf died of ventricular fibrillation intraoperatively. One calf that had been heparinized developed uncontrollable hemothorax and died 12 h postoperatively. One calf prematurely dislodged his aortic cannula 15 h postoperatively and exsanguinated. Six calves developed pelvic limb paresis or paralysis because of lumbar spinal cord thromboembolism by 36 h postoperatively, and 3 of these calves were sacrificed by 42 h postoperatively. Fifteen calves required sedation in the first 12 h after the operation. Tachycardia associated with bottle feeding occurred in 15 calves. Second-degree atrioventricular block was noted frequently during deep relaxation. Postmortem examination demonstrated the absence of surgical wound and distant infection, security of cannulae in all but the calf that prematurely dislodged the aortic cannula, absence of thrombus formation at cannulation sites, and presence of thromboembolism in 51% of the calves. The incidence of thromboembolic lesions was not influenced by the need for chemical restraint, by the occurrence of feeding-associated tachycardia, or by the presence of atrioventricular block. There were no thromboembolic lesions in any of the sham-operated controls.


    • 1 February 1996
      • Vol. 93  (2) , 86-7

    Improved method for deep thoracoscopic lung nodule excision.

    by T L Demmy, D Nielson, J J Curtis

    Minimally invasive excision of deep lung nodules can be difficult partly because endoscopic staplers do not open wide enough. We describe a method in which a standard atraumatic straight clamp compresses the lung to allow placement of the stapler without difficulty.