  • Laboratory confirmation of clinical heart allograft preservation variability

    by Todd L Demmy, Timothy A Turpin, Colette C Wagner-Mann


    • 1 January 1999
      • Vol. 96  (1) , 14-7

    The heartmate left ventricular assist system: first successful implantation in Missouri.

    by W R Wilson, J J Curtis, T L Demmy, G E Greer, D J Voelker, H K Reddy, D Villarreal

    We report a case of the first successful implantation of the HeartMate left ventricular assist system as a bridge to heart transplant in the state of Missouri. Indications, technique of insertion, patient selection, outcomes and future applications are discussed.

    • 14 November 1997
      • Vol. 43  (5) , M414-7

    In vivo left ventricular assist induced coagulation derangements. Comparison of Sarns-3M and St. Jude Medical circuits.

    by J J Curtis, C C Wagner-Mann, F A Mann, T L Demmy, J T Walls, R A Schmaltz

    An in vitro comparison of centrifugal pumping systems manufactured by Sarns-3M and St. Jude Medical revealed a difference in blood cell derangement. The purpose of this study was to compare in vivo the effects of 96 hr of left ventricular assist (LVA) on indexes of coagulopathy, hemolysis, and complement activation. Two groups of calves (each: n = 5) were instrumented with identical left atrial to thoracic aorta centrifugal pumping circuits using either Sarns-3M or St. Jude centrifugal pumps. Laboratory evaluations were performed pre-assist and at 1, 4, 24, 48, 72, and 96 hr during LVA. Platelet counts dropped significantly by 24 hr (Sarns-3M: 28%; St. Jude: 30%); no significant change in function was noted. Activated clotting time increased slightly (p > 0.05). Prothrombin time increased at 4 and 24 hr of LVA, returning to baseline by 96 hr (p < 0.05). Activated partial thromboplastin time increased with the St. Jude device from 24 to 96 hr on LVA (p < 0.05); the increase with the Sarns-3M device never reached significance. No significant changes in lactate dehydrogenase or plasma free hemoglobin were detected. Complement fraction C5a rose by 1 hr of LVA (p < 0.05), peaking at 4 hr and returning to baseline by 96 hr with both pumps. No significant difference was detected between pump groups for any of the parameters. It was concluded that 1) 96 hr Sarns-3M and St. Jude LVA caused coagulation derangement in calves, 2) neither pump demonstrated an advantage regarding coagulation and complement parameters, 3) hemolysis observed with the Sarns-3M pump in vitro was not evidenced in vivo, and 4) in vitro evidenced centrifugal pump differences may not be realized in vivo.

    • 1 June 1996
      • Vol. 20  (6) , 670-7

    A calf model for left ventricular centrifugal mechanical assist.

    by F A Mann, C C Wagner-Mann, J J Curtis, T L Demmy, J R Turk

    The increased use of centrifugal mechanical assist (CMA) for treatment of refractory postcardiotomy cardiogenic shock highlights the need for experimental testing to improve clinical results. This report describes the preoperative conditioning, anesthetic and surgical technique, and postoperative management of a reliable calf model refined in this laboratory for in vivo subchronic (96 h) testing of CMA. Holstein bull calves (2 to 3 months old; mean body weight, 78 kg; n = 35) were instrumented for left ventricular CMA; 4 of these calves were sham-operated controls. Anesthetic recovery and postoperative restraint were accomplished in a specially designed crate to which each calf was preconditioned extensively. Younger calves were more readily conditioned and more tolerant of postoperative restraint than older calves. One calf died of ventricular fibrillation intraoperatively. One calf that had been heparinized developed uncontrollable hemothorax and died 12 h postoperatively. One calf prematurely dislodged his aortic cannula 15 h postoperatively and exsanguinated. Six calves developed pelvic limb paresis or paralysis because of lumbar spinal cord thromboembolism by 36 h postoperatively, and 3 of these calves were sacrificed by 42 h postoperatively. Fifteen calves required sedation in the first 12 h after the operation. Tachycardia associated with bottle feeding occurred in 15 calves. Second-degree atrioventricular block was noted frequently during deep relaxation. Postmortem examination demonstrated the absence of surgical wound and distant infection, security of cannulae in all but the calf that prematurely dislodged the aortic cannula, absence of thrombus formation at cannulation sites, and presence of thromboembolism in 51% of the calves. The incidence of thromboembolic lesions was not influenced by the need for chemical restraint, by the occurrence of feeding-associated tachycardia, or by the presence of atrioventricular block. There were no thromboembolic lesions in any of the sham-operated controls.


    • 1 February 1996
      • Vol. 93  (2) , 86-7

    Improved method for deep thoracoscopic lung nodule excision.

    by T L Demmy, D Nielson, J J Curtis

    Minimally invasive excision of deep lung nodules can be difficult partly because endoscopic staplers do not open wide enough. We describe a method in which a standard atraumatic straight clamp compresses the lung to allow placement of the stapler without difficulty.

    • 1 September 1993
      • Vol. 12  (5) , 736-40

    Immunostaining of cardiac biopsy specimens in the diagnosis of acute vascular (humoral) rejection: a control study.

    by T S Loy, I S Bulatao, G V Darkow, T L Demmy, H K Reddy, J Curtis, J T Bickel

    The diagnosis of acute vascular (humoral) rejection in heart transplant biopsies is classically based on immunofluorescent studies of frozen tissue that show vascular staining for immunoglobulin and complement. We have noted that some pathologists have used immunostaining of formalin-fixed, paraffin-embedded tissue in testing for vascular rejection. To determine the specificity of immunostaining of heart biopsy specimens in the diagnosis of vascular rejection, we studied tissue from 68 consecutive endomyocardial biopsies from 16 patients without clinical or histologic evidence of vascular rejection. In each case, routinely processed formalin-fixed, paraffin-embedded tissue was stained for immunoglobulin G and immunoglobulin M with an avidin-biotin immunoperoxidase technique. Frozen tissue from each case was also stained for immunoglobulin G, immunoglobulin M, C3, and Clq by immunofluorescence. Immunoperoxidase stains on formalin-fixed tissue showed vascular staining for immunoglobulin in 67 of 68 (99%) of the cases. Staining was ablated if the antibodies were absorbed with their appropriate immunoglobulin. Immunofluorescent studies on frozen tissue showed no vascular staining for immunoglobulin or complement. We conclude that immunoperoxidase studies of routinely processed, formalin-fixed, paraffin-embedded tissues are nonspecific in the diagnosis of heart acute vascular rejection. The positive staining in fixed tissues may be due to labeling of passive immunoglobulins that are "fixed" in the vessels during routine processing but are washed away in techniques using frozen tissue.


  • Clinical Experience with the Sarns Centrifugal Pump

    by Jack J. Curtis, Joseph T. Walls, Todd L. Demmy, Theresa M. Boley, Richard A. Schmaltz, Catherine F. Goss, Colette C. Wagner‐Mann

    Since October 1986, we have had experience with 96 Sarns centrifugal pumps in 72 patients (pts). Heparinless left atrial to femoral artery or aorta bypass was used in 14 pts undergoing surgery on the thoracic aorta with 13 survivors (93%). No paraplegia or device-related complications were observed. In 57 patients, the Sarns centrifugal pump was used as a univentricular (27 pts) or biventricular (30 pts) cardiac assist device for postcardiotomy cardiogenic shock. In these patients, cardiac assist duration ranged from 2 to 434 h with a hospital survival rate of 29% in those requiring left ventricular assist and 13% in those requiring biventricular assist. Although complications were ubiquitous in this mortally ill patient population, in 5,235 pump-hours, no pump thrombosis was observed. Hospital survivors followed for 4 months to 6 years have enjoyed an improved functional class. We conclude that the Sarns centrifugal pump is an effective cardiac assist device when used to salvage patients otherwise unweanable from cardiopulmonary bypass. Partial left ventricular bypass using a centrifugal pump has become our procedure of choice for unloading the left ventricle and for maintenance of distal aortic perfusion pressure when performing surgery on the thoracic aorta. This clinical experience with the Sarns centrifugal pump appears to be similar to that reported with other centrifugal assist devices.