Richard Aufrichtig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard Aufrichtig has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Ping Xue
GE Medical Systems, X-ray Systems Engineering, Milwaukee, WI, USA
2 shared publicationsCecil W. Thomas
Department of Biomedical Engineering and Department of Psychology, Case Western Reserve University, Cleveland, Ohio 44106 USA
1 shared publicationDavid L. Wilson
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106, and Department of Radiology, University Hospitals of Cleveland, Cleveland, Ohio 44106 USA
1 shared publication
Latest Publications
- 25 August 2000
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (9) , 2653-2669
Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
The effect of dose reduction on low-contrast detectability is investigated theoretically and experimentally for a production grade amorphous silicon (a-Si) x-ray detector and compared with a standard thoracic screen-film combination. A non-prewhitening matched filter observer model modified to include a spatial response function and internal noise for the human visual system (HVS) is used to calculate a signal-to-noise ratio (SNR) related to object detectability. Other inputs to the SNR calculation are the detective quantum efficiency (DQE) and the modulation transfer function (MTF) of the imaging system. Besides threshold detectability, the model predicts the equivalent perception dose ratio (EPDR), which is the fraction of the screen film exposure for which the digital detector provides equal detectability. Images of a contrast-detail phantom are obtained with the digital detector at dose levels corresponding to 27%, 41%, 63% and 100% of the dose used for screen-film. The images are used in a four-alternative forced choice (4-AFC) observer perception study in order to measure threshold detectability. A statistically significant improvement in contrast detectability is measured with the digital detector at 100% and 63% of the screen-film dose. There is no statistical difference between screen-film and digital at 41% of the dose. On average, the experimental EPDR is 44%, which agrees well with the model prediction of 40%.
- 25 August 2000
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (9) , 2653-2669
Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
The effect of dose reduction on low-contrast detectability is investigated theoretically and experimentally for a production grade amorphous silicon (a-Si) x-ray detector and compared with a standard thoracic screen-film combination. A non-prewhitening matched filter observer model modified to include a spatial response function and internal noise for the human visual system (HVS) is used to calculate a signal-to-noise ratio (SNR) related to object detectability. Other inputs to the SNR calculation are the detective quantum efficiency (DQE) and the modulation transfer function (MTF) of the imaging system. Besides threshold detectability, the model predicts the equivalent perception dose ratio (EPDR), which is the fraction of the screen film exposure for which the digital detector provides equal detectability. Images of a contrast-detail phantom are obtained with the digital detector at dose levels corresponding to 27%, 41%, 63% and 100% of the dose used for screen-film. The images are used in a four-alternative forced choice (4-AFC) observer perception study in order to measure threshold detectability. A statistically significant improvement in contrast detectability is measured with the digital detector at 100% and 63% of the screen-film dose. There is no statistical difference between screen-film and digital at 41% of the dose. On average, the experimental EPDR is 44%, which agrees well with the model prediction of 40%.
- 12 July 1999
- Published by Wiley in Medical Physics
- Vol. 26 (7) , 1349-1358
Comparison of low contrast detectability between a digital amorphous silicon and a screen‐film based imaging system for thoracic radiography
Low contrast threshold detectability is investigated theoretically and experimentally for an amorphous silicon x‐ray detector designed for digital radiography and for a standard thoracic screen‐film combination. A theoretical signal‐to‐noise ratio is described with a human observer signal detection model. It is calculated using the detective quantum efficiency (DQE) and the modulation transfer function of the imaging system, as well as a spatial response function for the human visual system. Using a four‐alternative forced choice observer perception study, the threshold contrasts of disk shaped objects ranging in size from 0.3 to 4.0 mm are determined. Significantly better contrast detectability is obtained from the digital detector, which is attributed to its higher DQE. On average, the disk shaped objects can be detected at 45% less contrast than required for screen‐film. With no free parameters the experimental data agree well with those predicted by the observer model. Based upon the data, the model predicts that x‐ray exposure for the detector only needs to be 30% of the exposure required to perform equally well on the contrast‐detail detectability task using screen‐film.
- 12 July 1999
- Published by Wiley in Medical Physics
- Vol. 26 (7) , 1349-1358
Comparison of low contrast detectability between a digital amorphous silicon and a screen‐film based imaging system for thoracic radiography
Low contrast threshold detectability is investigated theoretically and experimentally for an amorphous silicon x‐ray detector designed for digital radiography and for a standard thoracic screen‐film combination. A theoretical signal‐to‐noise ratio is described with a human observer signal detection model. It is calculated using the detective quantum efficiency (DQE) and the modulation transfer function of the imaging system, as well as a spatial response function for the human visual system. Using a four‐alternative forced choice observer perception study, the threshold contrasts of disk shaped objects ranging in size from 0.3 to 4.0 mm are determined. Significantly better contrast detectability is obtained from the digital detector, which is attributed to its higher DQE. On average, the disk shaped objects can be detected at 45% less contrast than required for screen‐film. With no free parameters the experimental data agree well with those predicted by the observer model. Based upon the data, the model predicts that x‐ray exposure for the detector only needs to be 30% of the exposure required to perform equally well on the contrast‐detail detectability task using screen‐film.
- 1 December 1994
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 11 (12) , 3167-3176
Model for perception of pulsed fluoroscopy image sequences
Pulsed fluoroscopy at reduced frame rates can be used to lower x-ray dose with equivalent detection (hereafter called equivalent perception) of low-contrast, stationary objects. Experimentally average dose savings of 22%, 38%, and 49%, for pulsed fluoroscopy at 15, 10, and 7.5 acquisitions per second, respectively, are documented. Dose savings depend on object size, with fewer savings for smaller objects. To explain these data, we extend the framework of an ideal observer with three models for the spatiotemporal response of the human visual system (HVS). They are model 1, separable; model 2, nonseparable; and model 3, nonseparable with internal observer noise. With no free parameters, model 1 predicts the average dose savings within a 3% difference but does not describe the effect of object size. Models 2 and 3 explain the influence of size, and model 3, with a single free parameter, fits the measurements best. Perception of pulsed fluoroscopy is thus well described in terms of spatiotemporal processing by the HVS.
- 1 December 1994
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 11 (12) , 3167-3176
Model for perception of pulsed fluoroscopy image sequences
Pulsed fluoroscopy at reduced frame rates can be used to lower x-ray dose with equivalent detection (hereafter called equivalent perception) of low-contrast, stationary objects. Experimentally average dose savings of 22%, 38%, and 49%, for pulsed fluoroscopy at 15, 10, and 7.5 acquisitions per second, respectively, are documented. Dose savings depend on object size, with fewer savings for smaller objects. To explain these data, we extend the framework of an ideal observer with three models for the spatiotemporal response of the human visual system (HVS). They are model 1, separable; model 2, nonseparable; and model 3, nonseparable with internal observer noise. With no free parameters, model 1 predicts the average dose savings within a 3% difference but does not describe the effect of object size. Models 2 and 3 explain the influence of size, and model 3, with a single free parameter, fits the measurements best. Perception of pulsed fluoroscopy is thus well described in terms of spatiotemporal processing by the HVS.