Georgina Beltrán-Pérez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Georgina Beltrán-Pérez has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Severino Muñoz-Aguirre
Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 sur, Col. San Manuel CU, Puebla 72570, Mexico
15 shared publications J. Castillo-Mixcóatl
6 shared publications- Juan Castillo-Mixcóatl
Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 Sur, Colonia San Manuel, Edificio FM1-101B, Ciudad Universitaria, Puebla C.P. 72570, Mexico
6 shared publications - Marcos García-Juárez
Centro de Investigación en Reproducción Animal, Universidad Autónoma de Tlaxcala-CINVESTAV, Tlaxcala, Mexico
5 shared publications - Claudia Mendoza-Barrera
Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 Sur, Colonia San Manuel, Edificio FM1-101B, Ciudad Universitaria, Puebla C.P. 72570, Mexico
4 shared publications - Brenda Vertti-Cervantes
Instituto Politécnico Nacional, Centro de Investigación en Biotecnología Aplicada, Ex-Hacienda San Juan Molino Carretera Estatal Tecuexcomac, Tepetitla Km 1.5, Tlaxcala C.P. 90700, Mexico
3 shared publications
Latest Publications
- Open Access
Development of a Smart Sensor for Acetone Detection Using Long-Period Fiber Grating and Machine Learning
Long-period fiber gratings (LPFGs) are widely used for the development of different types of sensors. It has recently been demonstrated that the use of Principal Component Analysis (PCA) can greatly simplify the analysis of the response of this type of sensor. By applying PCA to the transmission spectra of LPFG, the relationship between them and the magnitude of the physical variable of interest can be clearly observed. On the other hand, machine learning (ML) algorithms have proven to be very useful in identifying patterns and data regressions. This paper presents the characterization of an LPFG-based acetone sensor and its study using PCA as a dimension reduction technique, as well as the ML algorithm called support vector machine (SVM) as a multi-class classifier, to qualitatively and quantitatively determine the level of acetone concentration measured by the sensor. The results showed a reduction in the limit of detection (LOD) to 130 ppm at minute 15, as well as earlier detection at the first minute, with an increase in the LOD as a trade-off.
Open AccessDevelopment of a Smart Sensor for Acetone Detection Using Long-Period Fiber Grating and Machine Learning
Long-period fiber gratings (LPFGs) are widely used for the development of different types of sensors. It has recently been demonstrated that the use of Principal Component Analysis (PCA) can greatly simplify the analysis of the response of this type of sensor. By applying PCA to the transmission spectra of LPFG, the relationship between them and the magnitude of the physical variable of interest can be clearly observed. On the other hand, machine learning (ML) algorithms have proven to be very useful in identifying patterns and data regressions. This paper presents the characterization of an LPFG-based acetone sensor and its study using PCA as a dimension reduction technique, as well as the ML algorithm called support vector machine (SVM) as a multi-class classifier, to qualitatively and quantitatively determine the level of acetone concentration measured by the sensor. The results showed a reduction in the limit of detection (LOD) to 130 ppm at minute 15, as well as earlier detection at the first minute, with an increase in the LOD as a trade-off.
- Open Access
Classification of Volatile Organic Compounds Using a Novel High-Frequency Quartz Crystal Microbalance Sensor Array Based on Ethyl Cellulose Microstructures
Detecting volatile organic compounds (VOCs) is essential because they affect air quality and can serve as biomarkers for non-invasive early disease detection. VOCs can be identified using electronic noses combining cross-reactive sensors, pattern recognition, and classification algorithms. Here, a single-polymer 12-sensor array based on 30 MHz quartz crystal microbalances was developed using three ethyl cellulose (EC) microstructures: casting films (CFs), anti-solvent microparticles (ASMs), and electrospray microparticles (ESMs). The array detected ethanol, ethyl acetate, and heptane at ppm concentrations under controlled conditions of 20 °C and 20% relative humidity. Scanning electron micrographs exhibited average mesh-hole diameters of 1.13 ± 0.44 μm for CFs, and average particle diameters of 60 ± 15 nm and 1.1 ± 0.3 μm for ASMs and ESMs, respectively. FTIR spectra indicated O–H and H–O–H bending bands for ASMs and EC, whereas these bands were notably attenuated for ESMs, suggesting their affinities for polar and non-polar compounds, respectively. Mahalanobis distance and a support vector machine classifier accurately discriminated VOCs in principal component analysis space. Principal component regression and partial least squares regression predicted VOC concentrations with > 0.99, achieving estimated limits of detection of 143.6, 57, and 42.1 ppm by PCR and 70.5, 32.8, and 26.5 ppm by PLSR for ethanol, ethyl acetate, and heptane, respectively.Open AccessClassification of Volatile Organic Compounds Using a Novel High-Frequency Quartz Crystal Microbalance Sensor Array Based on Ethyl Cellulose Microstructures
Detecting volatile organic compounds (VOCs) is essential because they affect air quality and can serve as biomarkers for non-invasive early disease detection. VOCs can be identified using electronic noses combining cross-reactive sensors, pattern recognition, and classification algorithms. Here, a single-polymer 12-sensor array based on 30 MHz quartz crystal microbalances was developed using three ethyl cellulose (EC) microstructures: casting films (CFs), anti-solvent microparticles (ASMs), and electrospray microparticles (ESMs). The array detected ethanol, ethyl acetate, and heptane at ppm concentrations under controlled conditions of 20 °C and 20% relative humidity. Scanning electron micrographs exhibited average mesh-hole diameters of 1.13 ± 0.44 μm for CFs, and average particle diameters of 60 ± 15 nm and 1.1 ± 0.3 μm for ASMs and ESMs, respectively. FTIR spectra indicated O–H and H–O–H bending bands for ASMs and EC, whereas these bands were notably attenuated for ESMs, suggesting their affinities for polar and non-polar compounds, respectively. Mahalanobis distance and a support vector machine classifier accurately discriminated VOCs in principal component analysis space. Principal component regression and partial least squares regression predicted VOC concentrations with > 0.99, achieving estimated limits of detection of 143.6, 57, and 42.1 ppm by PCR and 70.5, 32.8, and 26.5 ppm by PLSR for ethanol, ethyl acetate, and heptane, respectively. - Open Access
- 12 September 2026
- Published by Elsevier in Optical Fiber Technology
- Vol. 103
Study in silico and experimental of a double-pass Mach–Zehnder interferometer sensor for acetone detection as a biomarker of diabetes mellitus
- 12 September 2026
- Published by Elsevier in Optical Fiber Technology
- Vol. 103
Open AccessStudy in silico and experimental of a double-pass Mach–Zehnder interferometer sensor for acetone detection as a biomarker of diabetes mellitus
- Open Access
Smart Sensor Based on Multiple Cascaded Michelson Interferometers with a Long-Period Fiber Grating for Recognition of Paracetamol Concentrations in Solutions
This work introduces a refractometric sensor based on multiple cascaded Michelson interferometers fabricated with long-period fiber gratings to classify different commercial brands of paracetamol as well as to measure solutions with different paracetamol concentrations. The operating principle is based on the interaction of light with the fiber–medium interface, such that variations in the refractive index provoke changes in the spectrum profile that can be measured at the output of the device. The brands used were Medley, Mejoral 500, Tempra, Tylenol, and excipient-free paracetamol (EFP). A support vector machine (SVM) classifier was used to recognize each brand with an F1-score of 92%. Also, using a projection to latent structures regression (PLSR), it was possible to quantify the paracetamol concentration with the best limit of detection (LOD) of 1.58 g/kg for the Mejoral brand.
Open AccessSmart Sensor Based on Multiple Cascaded Michelson Interferometers with a Long-Period Fiber Grating for Recognition of Paracetamol Concentrations in Solutions
This work introduces a refractometric sensor based on multiple cascaded Michelson interferometers fabricated with long-period fiber gratings to classify different commercial brands of paracetamol as well as to measure solutions with different paracetamol concentrations. The operating principle is based on the interaction of light with the fiber–medium interface, such that variations in the refractive index provoke changes in the spectrum profile that can be measured at the output of the device. The brands used were Medley, Mejoral 500, Tempra, Tylenol, and excipient-free paracetamol (EFP). A support vector machine (SVM) classifier was used to recognize each brand with an F1-score of 92%. Also, using a projection to latent structures regression (PLSR), it was possible to quantify the paracetamol concentration with the best limit of detection (LOD) of 1.58 g/kg for the Mejoral brand.
- Open Access
LPFG Biosensor for IL-6 Detection in Murine Serum Samples Associated with Ischemic Disease
Nowadays, optical fiber-based biosensors are widely used in various fields, particularly in medical diagnostics and the selection of appropriate treatments for certain diseases. One example is cerebral ischemic disease, where many biomarkers are released and provide valuable information about the severity and progression of the disease. In this study, a long-period fiber grating (LPFG) biosensor was developed using a standard single-mode optical fiber and monoclonal antibody (IL-6 mAb) as the biological recognition element to detect IL-6, which is a protein associated with the inflammatory process. The assembly of the LPFG biosensor was characterized through optical and electronic microscopy to observe morphological changes at different stages of fabrication and the detection process. Additionally, micro-infrared spectroscopy was employed to identify functional groups in the protein region linked to the presence of IL-6. Experimental data were analyzed using principal component analysis, confirming the biosensor’s ability to detect IL-6 and providing insights into its fabrication process.
Open AccessLPFG Biosensor for IL-6 Detection in Murine Serum Samples Associated with Ischemic Disease
Nowadays, optical fiber-based biosensors are widely used in various fields, particularly in medical diagnostics and the selection of appropriate treatments for certain diseases. One example is cerebral ischemic disease, where many biomarkers are released and provide valuable information about the severity and progression of the disease. In this study, a long-period fiber grating (LPFG) biosensor was developed using a standard single-mode optical fiber and monoclonal antibody (IL-6 mAb) as the biological recognition element to detect IL-6, which is a protein associated with the inflammatory process. The assembly of the LPFG biosensor was characterized through optical and electronic microscopy to observe morphological changes at different stages of fabrication and the detection process. Additionally, micro-infrared spectroscopy was employed to identify functional groups in the protein region linked to the presence of IL-6. Experimental data were analyzed using principal component analysis, confirming the biosensor’s ability to detect IL-6 and providing insights into its fabrication process.
- Open Access
Use of the Feature Scaling and Machine Learning Techniques on Optical Fiber Biosensors for the Detection of Neuroprotector IL-10 in Serum of a Murine Model with Cerebral Ischemia
Typically, response analysis of optical fiber biosensors focuses on changes in amplitude and wavelength shifts in the biosensor spectrum; therefore, not all of the spectral range is used for this analysis. On the other hand, if the entire spectrum is used, it is possible to leverage the current data in the spectrum and thus improve the performance of the biosensor. To do this, it is necessary to analyze a large amount of data present in each measured spectrum. This task can be made easier by using dimensionality reduction techniques. In addition, it is necessary to establish which spectral regions provide relevant information. Scaling techniques are mathematical data preprocessing tools used in machine learning to adjust the numerical scale of variables so that they have comparable weight and even highlight those characteristics that provide more information. To our knowledge, the use of these techniques in the development of optical fiber biosensors is not very common, which is why we believe they represent an attractive topic of study in this area. With the help of scaling techniques, we can modify the scale of the data so that all the information contained in the spectrum is used, regardless of its magnitude. In this work, two biosensors based on a chirped long period fiber grating (CLPFG) and a chirped Mach–Zehnder interferometer (CMZI) were developed for the detection of interleukin-10 (IL-10). Principal component analysis (PCA) was used as a dimensionality reduction technique together with a support vector machine (SVM) classifier with four different scaling techniques, standardization, minimum–maximum scaling, robust scaling, and a custom transformer, to compare the IL-10 detection performance of the biosensors. The results showed that robust scaling in CMZI performed best in detecting IL-10, with an F1-score equal to 1, as well as better reliability in detecting the protein.
Open AccessUse of the Feature Scaling and Machine Learning Techniques on Optical Fiber Biosensors for the Detection of Neuroprotector IL-10 in Serum of a Murine Model with Cerebral Ischemia
Typically, response analysis of optical fiber biosensors focuses on changes in amplitude and wavelength shifts in the biosensor spectrum; therefore, not all of the spectral range is used for this analysis. On the other hand, if the entire spectrum is used, it is possible to leverage the current data in the spectrum and thus improve the performance of the biosensor. To do this, it is necessary to analyze a large amount of data present in each measured spectrum. This task can be made easier by using dimensionality reduction techniques. In addition, it is necessary to establish which spectral regions provide relevant information. Scaling techniques are mathematical data preprocessing tools used in machine learning to adjust the numerical scale of variables so that they have comparable weight and even highlight those characteristics that provide more information. To our knowledge, the use of these techniques in the development of optical fiber biosensors is not very common, which is why we believe they represent an attractive topic of study in this area. With the help of scaling techniques, we can modify the scale of the data so that all the information contained in the spectrum is used, regardless of its magnitude. In this work, two biosensors based on a chirped long period fiber grating (CLPFG) and a chirped Mach–Zehnder interferometer (CMZI) were developed for the detection of interleukin-10 (IL-10). Principal component analysis (PCA) was used as a dimensionality reduction technique together with a support vector machine (SVM) classifier with four different scaling techniques, standardization, minimum–maximum scaling, robust scaling, and a custom transformer, to compare the IL-10 detection performance of the biosensors. The results showed that robust scaling in CMZI performed best in detecting IL-10, with an F1-score equal to 1, as well as better reliability in detecting the protein.
- Open Access
- 14 November 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 184
Projection to latent structures regression and its application to Mach–Zehnder interferometer optical fiber sensors for acetone detection
- 14 November 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 184
Open AccessProjection to latent structures regression and its application to Mach–Zehnder interferometer optical fiber sensors for acetone detection
- 9 October 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 326, 125261
ATR-FTIR spectroscopy to evaluate serum protein expression in a murine cerebral ischemia model
- 9 October 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 326, 125261
ATR-FTIR spectroscopy to evaluate serum protein expression in a murine cerebral ischemia model
- Open Access
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 104 (1) , 15
Detection of Interleukin 6 in a Sprague Dawley Rat’s Blood Plasma Using a Fiber Optic Biosensor with Long-Period Grating
The severity of various diseases is related to the concentration of interleukin 6 (IL-6), a proinflammatory cytokine crucial for the proliferation and differentiation of immunocompetent and hematopoietic cells. In ischemic cerebrovascular disease, it is known that, after traumatic injury, increased plasma levels of IL-6 are associated with neuronal inflammation and brain death. Research has shown that elevated plasma IL-6 levels within the first 12 h after an ischemic vascular event are strong predictors of early mortality. Therefore, developing a device that can detect the presence of IL-6 in a murine model of induced ischemic disease could be beneficial for monitoring the disease and selecting the appropriate treatment in the future. This study aimed to detect IL-6 using biosensors developed within optical fibers; the biosensors were assembled using a self-assembled monolayer technique. Subsequently, detection was carried out using samples from rats (Sprague Dawley strain) with an induced ischemic disease. Samples were left to interact with the sample for 2 h to characterize the changes in the sensor’s transmission response. Both the response of the biosensor to IL-6 and the self-assembly steps were characterized by transmission spectroscopy at wavelengths of 1250–1450 nm and micro-MIR spectroscopy. Spectral changes were observed at different stages of the assembly and detection processes. By performing a PCA on the experimental data, it was possible to observe the clustering of the different assembly stages and the final detection. This allowed for discrimination not only at the stage of the biosensor’s construction but also in its detection of IL-6.
- 28 May 2024
- Published by MDPI AG in Proceedings
- Vol. 104 (1) , 15
Open AccessDetection of Interleukin 6 in a Sprague Dawley Rat’s Blood Plasma Using a Fiber Optic Biosensor with Long-Period Grating
The severity of various diseases is related to the concentration of interleukin 6 (IL-6), a proinflammatory cytokine crucial for the proliferation and differentiation of immunocompetent and hematopoietic cells. In ischemic cerebrovascular disease, it is known that, after traumatic injury, increased plasma levels of IL-6 are associated with neuronal inflammation and brain death. Research has shown that elevated plasma IL-6 levels within the first 12 h after an ischemic vascular event are strong predictors of early mortality. Therefore, developing a device that can detect the presence of IL-6 in a murine model of induced ischemic disease could be beneficial for monitoring the disease and selecting the appropriate treatment in the future. This study aimed to detect IL-6 using biosensors developed within optical fibers; the biosensors were assembled using a self-assembled monolayer technique. Subsequently, detection was carried out using samples from rats (Sprague Dawley strain) with an induced ischemic disease. Samples were left to interact with the sample for 2 h to characterize the changes in the sensor’s transmission response. Both the response of the biosensor to IL-6 and the self-assembly steps were characterized by transmission spectroscopy at wavelengths of 1250–1450 nm and micro-MIR spectroscopy. Spectral changes were observed at different stages of the assembly and detection processes. By performing a PCA on the experimental data, it was possible to observe the clustering of the different assembly stages and the final detection. This allowed for discrimination not only at the stage of the biosensor’s construction but also in its detection of IL-6.