Juan Castillo-Mixcóatl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juan Castillo-Mixcóatl has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Georgina Beltrán-Pérez
Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 sur, Col. San Manuel CU, Puebla 72570, Mexico
6 shared publications - Severino Muñoz-Aguirre
Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 sur, Col. San Manuel CU, Puebla 72570, Mexico
6 shared publications - Claudia Mendoza-Barrera
Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 Sur, Colonia San Manuel, Edificio FM1-101B, Ciudad Universitaria, Puebla C.P. 72570, Mexico
4 shared publications - Víctor Altuzar
Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla 72570, Mexico
3 shared publications - Marcos Rodríguez-Torres
Facultad de Ciencias Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Avenida San Claudio y 18 Sur, Colonia San Manuel, Edificio FM1-101B, Ciudad Universitaria, Puebla 72570, Mexico
2 shared publications S. Muñoz-Aguirre
2 shared publications
Latest Publications
- Open Access
Classification of Volatile Organic Compounds Using a Novel High-Frequency Quartz Crystal Microbalance Sensor Array Based on Ethyl Cellulose Microstructures
Detecting volatile organic compounds (VOCs) is essential because they affect air quality and can serve as biomarkers for non-invasive early disease detection. VOCs can be identified using electronic noses combining cross-reactive sensors, pattern recognition, and classification algorithms. Here, a single-polymer 12-sensor array based on 30 MHz quartz crystal microbalances was developed using three ethyl cellulose (EC) microstructures: casting films (CFs), anti-solvent microparticles (ASMs), and electrospray microparticles (ESMs). The array detected ethanol, ethyl acetate, and heptane at ppm concentrations under controlled conditions of 20 °C and 20% relative humidity. Scanning electron micrographs exhibited average mesh-hole diameters of 1.13 ± 0.44 μm for CFs, and average particle diameters of 60 ± 15 nm and 1.1 ± 0.3 μm for ASMs and ESMs, respectively. FTIR spectra indicated O–H and H–O–H bending bands for ASMs and EC, whereas these bands were notably attenuated for ESMs, suggesting their affinities for polar and non-polar compounds, respectively. Mahalanobis distance and a support vector machine classifier accurately discriminated VOCs in principal component analysis space. Principal component regression and partial least squares regression predicted VOC concentrations with > 0.99, achieving estimated limits of detection of 143.6, 57, and 42.1 ppm by PCR and 70.5, 32.8, and 26.5 ppm by PLSR for ethanol, ethyl acetate, and heptane, respectively.Open AccessClassification of Volatile Organic Compounds Using a Novel High-Frequency Quartz Crystal Microbalance Sensor Array Based on Ethyl Cellulose Microstructures
Detecting volatile organic compounds (VOCs) is essential because they affect air quality and can serve as biomarkers for non-invasive early disease detection. VOCs can be identified using electronic noses combining cross-reactive sensors, pattern recognition, and classification algorithms. Here, a single-polymer 12-sensor array based on 30 MHz quartz crystal microbalances was developed using three ethyl cellulose (EC) microstructures: casting films (CFs), anti-solvent microparticles (ASMs), and electrospray microparticles (ESMs). The array detected ethanol, ethyl acetate, and heptane at ppm concentrations under controlled conditions of 20 °C and 20% relative humidity. Scanning electron micrographs exhibited average mesh-hole diameters of 1.13 ± 0.44 μm for CFs, and average particle diameters of 60 ± 15 nm and 1.1 ± 0.3 μm for ASMs and ESMs, respectively. FTIR spectra indicated O–H and H–O–H bending bands for ASMs and EC, whereas these bands were notably attenuated for ESMs, suggesting their affinities for polar and non-polar compounds, respectively. Mahalanobis distance and a support vector machine classifier accurately discriminated VOCs in principal component analysis space. Principal component regression and partial least squares regression predicted VOC concentrations with > 0.99, achieving estimated limits of detection of 143.6, 57, and 42.1 ppm by PCR and 70.5, 32.8, and 26.5 ppm by PLSR for ethanol, ethyl acetate, and heptane, respectively. - Open Access
Acetone Detection and Classification as Biomarker of Diabetes Mellitus Using a Quartz Crystal Microbalance Gas Sensor Array
A gas sensor array was developed and evaluated using four high-frequency quartz crystal microbalance devices (with a 30 MHz resonant frequency in fundamental mode). The QCM devices were coated with ethyl cellulose (EC), polymethylmethacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) sensing films, and deposited by the ultrasonic atomization method. The objective of this research was to propose a non-invasive technique for acetone biomarker detection, which is associated with diabetes mellitus disease. The gas sensor array was exposed to methanol, ethanol, isopropanol, and acetone biomarkers in four different concentrations, corresponding to 1, 5, 10, and 15 µL, at temperature of 22 °C and relative humidity of 20%. These samples were used because human breath contains them and they are used for disease detection. Moreover, the gas sensor responses were analyzed using principal component analysis and discriminant analysis, achieving the classification of the acetone biomarker with a 100% membership percentage when its concentration varies from 327 to 4908 ppm, and its identification from methanol, ethanol, and isopropanol.
Open AccessAcetone Detection and Classification as Biomarker of Diabetes Mellitus Using a Quartz Crystal Microbalance Gas Sensor Array
A gas sensor array was developed and evaluated using four high-frequency quartz crystal microbalance devices (with a 30 MHz resonant frequency in fundamental mode). The QCM devices were coated with ethyl cellulose (EC), polymethylmethacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) sensing films, and deposited by the ultrasonic atomization method. The objective of this research was to propose a non-invasive technique for acetone biomarker detection, which is associated with diabetes mellitus disease. The gas sensor array was exposed to methanol, ethanol, isopropanol, and acetone biomarkers in four different concentrations, corresponding to 1, 5, 10, and 15 µL, at temperature of 22 °C and relative humidity of 20%. These samples were used because human breath contains them and they are used for disease detection. Moreover, the gas sensor responses were analyzed using principal component analysis and discriminant analysis, achieving the classification of the acetone biomarker with a 100% membership percentage when its concentration varies from 327 to 4908 ppm, and its identification from methanol, ethanol, and isopropanol.
- Open Access
- 9 July 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (15) , 23439-23446
Thermocavitation: a mechanism to pulse fiber lasers
In this paper, we present a novel mechanism for the generation of laser pulses based on the phenomenon of thermocavitation. Thermocavitation bubbles were generated within a glass cuvette filled with copper nitrate dissolved in water, where the tip of an optical fiber was placed very close to the bubble generation region. Once the bubble is generated, it expands rapidly and the incoming laser light transmitted through the optical fiber is reflected at the vapor-solution interface and reflected back into the fiber, which is coupled to an erbium-doped fiber ring laser. Laser pulses were extracted from the ring cavity and detected by a fast photodetector, which corresponds to a single thermocavitation event, obtaining a pulse repetition rate from 118 Hz to 2 kHz at 1560 nm, with a pulse width ranging from 64 to 57 µs. The repetition rate can be controlled by adjusting the laser power to induce thermocavitation. To our knowledge, this novel mechanism of laser pulses has not been reported in the literature.
- 9 July 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (15) , 23439-23446
Open AccessThermocavitation: a mechanism to pulse fiber lasers
In this paper, we present a novel mechanism for the generation of laser pulses based on the phenomenon of thermocavitation. Thermocavitation bubbles were generated within a glass cuvette filled with copper nitrate dissolved in water, where the tip of an optical fiber was placed very close to the bubble generation region. Once the bubble is generated, it expands rapidly and the incoming laser light transmitted through the optical fiber is reflected at the vapor-solution interface and reflected back into the fiber, which is coupled to an erbium-doped fiber ring laser. Laser pulses were extracted from the ring cavity and detected by a fast photodetector, which corresponds to a single thermocavitation event, obtaining a pulse repetition rate from 118 Hz to 2 kHz at 1560 nm, with a pulse width ranging from 64 to 57 µs. The repetition rate can be controlled by adjusting the laser power to induce thermocavitation. To our knowledge, this novel mechanism of laser pulses has not been reported in the literature.
- Open Access
Discrimination Improvement of a Gas Sensors’ Array Using High-Frequency Quartz Crystal Microbalance Coated with Polymeric Films
The discrimination improvement of an array of four highly sensitive 30 MHz gas quartz crystal microbalance (QCM) sensors was performed and compared to a similar system based on a 12-MHz QCM. The sensing polymeric films were ethyl cellulose (EC), poly-methyl methacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) and they were coated over the AT-cut QCM devices by the drop casting technique. All the sensors had almost the same film thickness (0.2 μm). The fabricated QCM sensor arrays were exposed to three different concentrations, corresponding to 5, 10, and 15 μL, of ethanol, ethyl acetate, and heptane vapors. The steady state sensor responses were measured in a static system at a temperature of 20 °C and relative humidity of 22%. Our results showed that the 30-MHz sensors have a higher sensitivity than 12-MHz ones (around 5.73 times), independently of the sensing film and measured sample. On the other hand, principal component analysis and discriminant analysis were performed using the raw data of the responses. An improvement of the classification percentage between 12 MHz and 30 MHz sensors was found. However, it was not sufficient, especially for low concentrations. Furthermore, using partition coefficient and discriminant analysis (DA), an improvement of 100% classification of the three samples was achieved for the case of the 30-MHz sensor array.
Open AccessDiscrimination Improvement of a Gas Sensors’ Array Using High-Frequency Quartz Crystal Microbalance Coated with Polymeric Films
The discrimination improvement of an array of four highly sensitive 30 MHz gas quartz crystal microbalance (QCM) sensors was performed and compared to a similar system based on a 12-MHz QCM. The sensing polymeric films were ethyl cellulose (EC), poly-methyl methacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) and they were coated over the AT-cut QCM devices by the drop casting technique. All the sensors had almost the same film thickness (0.2 μm). The fabricated QCM sensor arrays were exposed to three different concentrations, corresponding to 5, 10, and 15 μL, of ethanol, ethyl acetate, and heptane vapors. The steady state sensor responses were measured in a static system at a temperature of 20 °C and relative humidity of 22%. Our results showed that the 30-MHz sensors have a higher sensitivity than 12-MHz ones (around 5.73 times), independently of the sensing film and measured sample. On the other hand, principal component analysis and discriminant analysis were performed using the raw data of the responses. An improvement of the classification percentage between 12 MHz and 30 MHz sensors was found. However, it was not sufficient, especially for low concentrations. Furthermore, using partition coefficient and discriminant analysis (DA), an improvement of 100% classification of the three samples was achieved for the case of the 30-MHz sensor array.
- Open Access
An Application of the Gaussian Plume Model to Localization of an Indoor Gas Source with a Mobile Robot
The source localization of gas leaks is important to avoid any potential danger to the surroundings or the probable waste of resources. Currently there are several localization methods using robotic systems that try to find the origin of a gas plume. Many of these methods require wind velocity information involving the use of commercial anemometric systems which are extremely expensive compared to metal oxide gas sensors. This article proposes the validation of the Gaussian plume model inside an empty room and its application to localize the source of a gas plume without employing anemometric sensors, exclusively using concentration data. The model was selected due to its simplicity and since it easily admits variants closer to reality, explaining the behavior of pollutants transported by the wind. An artificial gas source was generated by a conventional fan and liquid ethanol as contaminant. We found that the physical fan, far from making the model impossible to implement, enriched the information and added realism. The use of a robotic system capable of autonomously mapping the room concentration distribution is described. The results showed that the Gaussian plume model is applicable to localize our experimental gas source. An estimated position of the source with a deviation of 14 cm (6.1%) was obtained.
Open AccessAn Application of the Gaussian Plume Model to Localization of an Indoor Gas Source with a Mobile Robot
The source localization of gas leaks is important to avoid any potential danger to the surroundings or the probable waste of resources. Currently there are several localization methods using robotic systems that try to find the origin of a gas plume. Many of these methods require wind velocity information involving the use of commercial anemometric systems which are extremely expensive compared to metal oxide gas sensors. This article proposes the validation of the Gaussian plume model inside an empty room and its application to localize the source of a gas plume without employing anemometric sensors, exclusively using concentration data. The model was selected due to its simplicity and since it easily admits variants closer to reality, explaining the behavior of pollutants transported by the wind. An artificial gas source was generated by a conventional fan and liquid ethanol as contaminant. We found that the physical fan, far from making the model impossible to implement, enriched the information and added realism. The use of a robotic system capable of autonomously mapping the room concentration distribution is described. The results showed that the Gaussian plume model is applicable to localize our experimental gas source. An estimated position of the source with a deviation of 14 cm (6.1%) was obtained.
- 1 September 2018
- Published by Elsevier in Optics & Laser Technology
- Vol. 105, 118-128
Adaptive optics system simulator
- 1 September 2018
- Published by Elsevier in Optics & Laser Technology
- Vol. 105, 118-128
Adaptive optics system simulator
- Open Access
Reduction of the Measurement Time by the Prediction of the Steady-State Response for Quartz Crystal Microbalance Gas Sensors
This paper presents a new approach to reduce the measurement time by the prediction of the steady-state using the transient response to ethanol for quartz crystal microbalance gas sensors coated with ethyl cellulose. The experimentally measured response curves were successively fitted using a mathematical model based on the sum of two exponentials with different time constants. The parameters of the model were determined, and the time constants and the magnitude of the steady-state response were analyzed. Even though the time constants did not stabilize well, the parameter corresponding to the magnitude of the steady-state response quickly converged and stabilized after 37 s. Moreover, this calculated parameter was highly correlated with the measured values of the steady-state response, which was measured at five times the longest time constant (83 s) of the model. Therefore, the steady-state response could be predicted with a 55% reduction in the measurement (detection) time.
Open AccessReduction of the Measurement Time by the Prediction of the Steady-State Response for Quartz Crystal Microbalance Gas Sensors
This paper presents a new approach to reduce the measurement time by the prediction of the steady-state using the transient response to ethanol for quartz crystal microbalance gas sensors coated with ethyl cellulose. The experimentally measured response curves were successively fitted using a mathematical model based on the sum of two exponentials with different time constants. The parameters of the model were determined, and the time constants and the magnitude of the steady-state response were analyzed. Even though the time constants did not stabilize well, the parameter corresponding to the magnitude of the steady-state response quickly converged and stabilized after 37 s. Moreover, this calculated parameter was highly correlated with the measured values of the steady-state response, which was measured at five times the longest time constant (83 s) of the model. Therefore, the steady-state response could be predicted with a 55% reduction in the measurement (detection) time.
- Open Access
- 31 December 2017
- Published by Instituto Politecnico Nacional/Centro de Investigacion en Computacion in Research in Computing Science
- Vol. 131 (1) , 43-48
Nonlinear Transmission of a NOLM with a Variable Wave Retarder inside the Loop
- 31 December 2017
- Published by Instituto Politecnico Nacional/Centro de Investigacion en Computacion in Research in Computing Science
- Vol. 131 (1) , 43-48
Open AccessNonlinear Transmission of a NOLM with a Variable Wave Retarder inside the Loop