Erik A. Hermans
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Erik A. Hermans has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Michiel Dubbelman
3 shared publicationsRob M. Heethaar
3 shared publicationsG.L. van der Heijde
1 shared publication- Joost P. A. Kuijer
Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Vrije Universiteit, Amsterdam, the Netherlands
1 shared publication M. Dubbelman
1 shared publication- Michiel Dubbelman
Department of Physics and Medical Technology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 1 January 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (1) , 281-9
Constant Volume of the Human Lens and Decrease in Surface Area of the Capsular Bag during Accommodation: An MRI and Scheimpflug Study
A change in surface area of the capsular bag and a change in volume of the lens can indicate whether a change in the shape of the lens during accommodation is due to the compressibility or the elasticity of the lens material. 3D magnetic resonance imaging (MRI) was used to image the complete shape of the lens in a group of five healthy subjects between 18 and 35 years of age. A parametric representation of the cross-sectional shape was fitted to the edges of the lens, which were determined with a Canny edge filter. Based on a partition of the lens into eight parts, the parametric shape makes it possible to calculate the mean cross-sectional area, the volume, and the surface area as a function of accommodation. Corrected Scheimpflug imaging was used to validate the results obtained with MRI. No significant difference in central anterior and posterior radius of curvature and thickness was found between the MRI and Scheimpflug measurements. In accordance with the Helmholtz accommodation theory, a decrease in the anterior and posterior radius of curvature and equatorial diameter and an increase in lens thickness occurred with accommodation. During accommodation, the mean cross-sectional area increased and the surface area decreased. However, no significant change in lens volume was found. The preservation of lens volume implies that the internal human lens material can be assumed to be incompressible and is undergoing elastic deformation. Furthermore, the change in surface area indicates that the capsular bag also undergoes elastic deformation.
- 1 January 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (1) , 281-9
Constant Volume of the Human Lens and Decrease in Surface Area of the Capsular Bag during Accommodation: An MRI and Scheimpflug Study
A change in surface area of the capsular bag and a change in volume of the lens can indicate whether a change in the shape of the lens during accommodation is due to the compressibility or the elasticity of the lens material. 3D magnetic resonance imaging (MRI) was used to image the complete shape of the lens in a group of five healthy subjects between 18 and 35 years of age. A parametric representation of the cross-sectional shape was fitted to the edges of the lens, which were determined with a Canny edge filter. Based on a partition of the lens into eight parts, the parametric shape makes it possible to calculate the mean cross-sectional area, the volume, and the surface area as a function of accommodation. Corrected Scheimpflug imaging was used to validate the results obtained with MRI. No significant difference in central anterior and posterior radius of curvature and thickness was found between the MRI and Scheimpflug measurements. In accordance with the Helmholtz accommodation theory, a decrease in the anterior and posterior radius of curvature and equatorial diameter and an increase in lens thickness occurred with accommodation. During accommodation, the mean cross-sectional area increased and the surface area decreased. However, no significant change in lens volume was found. The preservation of lens volume implies that the internal human lens material can be assumed to be incompressible and is undergoing elastic deformation. Furthermore, the change in surface area indicates that the capsular bag also undergoes elastic deformation.
- 1 December 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (12) , 2133-2138
Development of a ciliary muscle–driven accommodating intraocular lens
PURPOSE: To develop a ciliary muscle–driven accommodating intraocular lens (IOL) that has a large and predictable range of variable power as a step toward spectacle independence. SETTING: Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands. METHODS: A concept IOL that has a rotating focus mechanism and a mechanical frame that can operate within the range of ciliary muscle contraction of a typical 60-year-old human eye was designed. Prototypes were made to test the IOL's mechanical performance in an enucleated pig's eye using a laboratory lens-stretching device that mimics the action of the human ciliary muscle. Changes in focal length during stretching were measured by laser-based ray tracing and a videocamera system. To rotate the 2 lenses in the IOL with variable optical power, a frame that allows the displacement and force of the ciliary muscle to be transferred by the capsular bag was designed. RESULTS: Ray tracing showed that the modulation transfer function (MTF) of the IOL in different accommodative states did not deviate to a great extent from the MTF of a monofocal IOL. During stretching experiments, the prototype IOL achieved 8.0 diopters of accommodation. CONCLUSIONS: Evaluation of an accommodating IOL that meets the requirements for a spectacle-independent solution to presbyopia showed that the mechanical and optical designs must be further optimized to improve optical quality and functionality.
- 1 December 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (12) , 2133-2138
Development of a ciliary muscle–driven accommodating intraocular lens
PURPOSE: To develop a ciliary muscle–driven accommodating intraocular lens (IOL) that has a large and predictable range of variable power as a step toward spectacle independence. SETTING: Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands. METHODS: A concept IOL that has a rotating focus mechanism and a mechanical frame that can operate within the range of ciliary muscle contraction of a typical 60-year-old human eye was designed. Prototypes were made to test the IOL's mechanical performance in an enucleated pig's eye using a laboratory lens-stretching device that mimics the action of the human ciliary muscle. Changes in focal length during stretching were measured by laser-based ray tracing and a videocamera system. To rotate the 2 lenses in the IOL with variable optical power, a frame that allows the displacement and force of the ciliary muscle to be transferred by the capsular bag was designed. RESULTS: Ray tracing showed that the modulation transfer function (MTF) of the IOL in different accommodative states did not deviate to a great extent from the MTF of a monofocal IOL. During stretching experiments, the prototype IOL achieved 8.0 diopters of accommodation. CONCLUSIONS: Evaluation of an accommodating IOL that meets the requirements for a spectacle-independent solution to presbyopia showed that the mechanical and optical designs must be further optimized to improve optical quality and functionality.
- 1 December 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (12) , 1179-1184
Equivalent Refractive Index of the Human Lens upon Accommodative Response
Purpose.: To experimentally verify the suggestion of Gullstrand (1909), i.e., that the equivalent refractive index of the human lens increases with accommodation. Methods.: The left eye of five subjects was focused on different accommodation stimuli, while the right eye was imaged with Scheimpflug photography in order to obtain the shape of the lens and cornea during accommodation. The procedure was then repeated, but instead of using the Scheimpflug camera, the accommodative response of the right eye was measured objectively with an aberrometer. The axial length was measured with a Zeiss IOL‐master. Combining the results of these measurements made it possible to correct the digital Scheimpflug images for corneal and lenticular refraction, and to simultaneously calculate the equivalent refractive index of the lens for all different accommodative stimuli. Furthermore, a two‐compartment model of the lens was constructed, with a nucleus and a cortex. Results.: In all five subjects there was no significant change in the equivalent refractive index of the lens as a function of accommodation. The mean equivalent refractive index was 1.435 ± 0.008. Furthermore, the accommodative response appeared to be lower than the accommodative stimulus (i.e., accommodative lag). It appeared to be possible to model the optical power of the lens, based on the geometry of cortex and nucleus. Based on a refractive index of 1.406 for the nucleus, the mean refractive index of the cortex was 1.381. Conclusions.: Gullstrand suggested that there would be an increase in the equivalent refractive index with accommodation; the intra‐capsulary mechanism of accommodation. However, we found that the equivalent refractive index of the lens does not change with accommodation when the accommodative lag is taken into account. Furthermore, it appeared to be possible to simulate the accommodative process of a subject with a two‐compartment model with constant refractive indices.
- 1 December 2008
- Published by Wiley in Optometry and Vision Science
- Vol. 85 (12) , 1179-1184
Equivalent Refractive Index of the Human Lens upon Accommodative Response
Purpose.: To experimentally verify the suggestion of Gullstrand (1909), i.e., that the equivalent refractive index of the human lens increases with accommodation. Methods.: The left eye of five subjects was focused on different accommodation stimuli, while the right eye was imaged with Scheimpflug photography in order to obtain the shape of the lens and cornea during accommodation. The procedure was then repeated, but instead of using the Scheimpflug camera, the accommodative response of the right eye was measured objectively with an aberrometer. The axial length was measured with a Zeiss IOL‐master. Combining the results of these measurements made it possible to correct the digital Scheimpflug images for corneal and lenticular refraction, and to simultaneously calculate the equivalent refractive index of the lens for all different accommodative stimuli. Furthermore, a two‐compartment model of the lens was constructed, with a nucleus and a cortex. Results.: In all five subjects there was no significant change in the equivalent refractive index of the lens as a function of accommodation. The mean equivalent refractive index was 1.435 ± 0.008. Furthermore, the accommodative response appeared to be lower than the accommodative stimulus (i.e., accommodative lag). It appeared to be possible to model the optical power of the lens, based on the geometry of cortex and nucleus. Based on a refractive index of 1.406 for the nucleus, the mean refractive index of the cortex was 1.381. Conclusions.: Gullstrand suggested that there would be an increase in the equivalent refractive index with accommodation; the intra‐capsulary mechanism of accommodation. However, we found that the equivalent refractive index of the lens does not change with accommodation when the accommodative lag is taken into account. Furthermore, it appeared to be possible to simulate the accommodative process of a subject with a two‐compartment model with constant refractive indices.
- Open Access
- 1 July 2007
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 7 (10) , 16
The shape of the human lens nucleus with accommodation
Knowledge about geometric properties such as shape and volume and Poisson's ratio of the nucleus can be used in the mechanical and optical modeling of the accommodation process. Therefore, Scheimpflug imaging was used to determine the shape of the human lens nucleus during accommodation in five subjects. To describe the shape of the nucleus, we fitted a parametric model of the cross-sectional geometry to the gradient of the Scheimpflug images using the Hough transform. The geometric model made it possible to estimate the anterior and the posterior central radius, central thickness, equatorial diameter, and cross-sectional area of the nucleus. Assuming that the nucleus is rotationally symmetric, the volume of the nucleus can be estimated by integrating around the circumference. For all five subjects, the results show that during accommodation the nucleus became more convex and that the central thickness increased whereas the equatorial diameter decreased. This decrease in equatorial diameter of the nucleus with accommodation is in accordance with the Helmholtz accommodation theory. Finally, the volume of the nucleus (on average 35 mm 3) showed no significant change during accommodation in any of the subjects, presumably due to the fact that the human nucleus consists of incompressible material with a Poisson's ratio that is near .5.
- 1 July 2007
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 7 (10) , 16
Open AccessThe shape of the human lens nucleus with accommodation
Knowledge about geometric properties such as shape and volume and Poisson's ratio of the nucleus can be used in the mechanical and optical modeling of the accommodation process. Therefore, Scheimpflug imaging was used to determine the shape of the human lens nucleus during accommodation in five subjects. To describe the shape of the nucleus, we fitted a parametric model of the cross-sectional geometry to the gradient of the Scheimpflug images using the Hough transform. The geometric model made it possible to estimate the anterior and the posterior central radius, central thickness, equatorial diameter, and cross-sectional area of the nucleus. Assuming that the nucleus is rotationally symmetric, the volume of the nucleus can be estimated by integrating around the circumference. For all five subjects, the results show that during accommodation the nucleus became more convex and that the central thickness increased whereas the equatorial diameter decreased. This decrease in equatorial diameter of the nucleus with accommodation is in accordance with the Helmholtz accommodation theory. Finally, the volume of the nucleus (on average 35 mm 3) showed no significant change during accommodation in any of the subjects, presumably due to the fact that the human nucleus consists of incompressible material with a Poisson's ratio that is near .5.
- 1 October 2006
- Published by Elsevier in Vision Research
- Vol. 46 (21) , 3642-3650
Estimating the external force acting on the human eye lens during accommodation by finite element modelling
- 1 October 2006
- Published by Elsevier in Vision Research
- Vol. 46 (21) , 3642-3650
Estimating the external force acting on the human eye lens during accommodation by finite element modelling