Tae-Youl Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tae-Youl Choi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dimos Poulikakos
Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
2 shared publications Kyung-Min Lee
University of North Texas
2 shared publicationsBoseon Kang
Department of Materials Science and Engineering|University of North Texas
1 shared publicationChang S Han
Department of Nanomechanical Systems|Korea Institute of Machinery and Materials
1 shared publicationD. S. Kim
POSTECH 3 Department of Mechanical Engineering San 31 Hyoja-Dong, Nam-Gu, Pohang, Gyungbuk 790-784, Korea
1 shared publication- Dongsik Kim
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea
1 shared publication
Latest Publications
- 6 December 2013
- Published by Springer Nature
- p. 359-371
Focused Ion Beam-Assisted Nanoscale Processing and Thermoelectrical Characterization
- 6 December 2013
- Published by Springer Nature
- p. 359-371
Focused Ion Beam-Assisted Nanoscale Processing and Thermoelectrical Characterization
- 1 March 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (3) , 034901
Steady heat conduction-based thermal conductivity measurement of single walled carbon nanotubes thin film using a micropipette thermal sensor
In this paper, we describe the thermal conductivity measurement of single-walled carbon nanotubes thin film using a laser point source-based steady state heat conduction method. A high precision micropipette thermal sensor fabricated with a sensing tip size varying from 2 μm to 5 μm and capable of measuring thermal fluctuation with resolution of ±0.01 K was used to measure the temperature gradient across the suspended carbon nanotubes (CNT) film with a thickness of 100 nm. We used a steady heat conduction model to correlate the temperature gradient to the thermal conductivity of the film. We measured the average thermal conductivity of CNT film as 74.3 ± 7.9 W m−1 K−1 at room temperature.
- 1 March 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (3) , 034901
Steady heat conduction-based thermal conductivity measurement of single walled carbon nanotubes thin film using a micropipette thermal sensor
In this paper, we describe the thermal conductivity measurement of single-walled carbon nanotubes thin film using a laser point source-based steady state heat conduction method. A high precision micropipette thermal sensor fabricated with a sensing tip size varying from 2 μm to 5 μm and capable of measuring thermal fluctuation with resolution of ±0.01 K was used to measure the temperature gradient across the suspended carbon nanotubes (CNT) film with a thickness of 100 nm. We used a steady heat conduction model to correlate the temperature gradient to the thermal conductivity of the film. We measured the average thermal conductivity of CNT film as 74.3 ± 7.9 W m−1 K−1 at room temperature.
- 22 December 2011
- Published by Springer Nature in Applied Physics A
- Vol. 106 (4) , 955-960
Highly enhanced thermoelectric figure of merit of a β-SiC nanowire with a nanoelectromechanical measurement approach
- 22 December 2011
- Published by Springer Nature in Applied Physics A
- Vol. 106 (4) , 955-960
Highly enhanced thermoelectric figure of merit of a β-SiC nanowire with a nanoelectromechanical measurement approach
- 1 November 2011
- Published by The Korean Society of Mechanical Engineers in Transactions of the Korean Society of Mechanical Engineers - B
- Vol. 35 (11) , 1133-1137
Fabrication of a Micro-thermoelectric Probe
- 1 November 2011
- Published by The Korean Society of Mechanical Engineers in Transactions of the Korean Society of Mechanical Engineers - B
- Vol. 35 (11) , 1133-1137
Fabrication of a Micro-thermoelectric Probe
- Open Access
A High-Precision Micropipette Sensor for Cellular-Level Real-Time Thermal Characterization
We report herein development of a novel glass micropipette thermal sensor fabricated in a cost-effective manner, which is capable of measuring steady thermal fluctuation at spatial resolution of ~2 µm with an accuracy of ±0.01 °C. We produced and tested various micrometer-sized sensors, ranging from 2 µm to 30 µm. The sensor comprises unleaded low-melting-point solder alloy (Sn-based) as a core metal inside a pulled borosilicate glass pipette and a thin film of nickel coating outside, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with an accuracy of ±0.01 °C, and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to 8.86 µV/°C. We have demonstrated the capability of measuring temperatures at a cellular level by inserting our temperature sensor into the membrane of a live retinal pigment epithelium cell subjected to a laser beam with a focal spot of 6 μm. We measured transient temperature profiles and the maximum temperatures were in the range of 38–55 ± 0.5 °C.
Open AccessA High-Precision Micropipette Sensor for Cellular-Level Real-Time Thermal Characterization
We report herein development of a novel glass micropipette thermal sensor fabricated in a cost-effective manner, which is capable of measuring steady thermal fluctuation at spatial resolution of ~2 µm with an accuracy of ±0.01 °C. We produced and tested various micrometer-sized sensors, ranging from 2 µm to 30 µm. The sensor comprises unleaded low-melting-point solder alloy (Sn-based) as a core metal inside a pulled borosilicate glass pipette and a thin film of nickel coating outside, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with an accuracy of ±0.01 °C, and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to 8.86 µV/°C. We have demonstrated the capability of measuring temperatures at a cellular level by inserting our temperature sensor into the membrane of a live retinal pigment epithelium cell subjected to a laser beam with a focal spot of 6 μm. We measured transient temperature profiles and the maximum temperatures were in the range of 38–55 ± 0.5 °C.
- 14 July 2009
- Published by IOP Publishing in Nanotechnology
- Vol. 20 (31) , 315706
Measurement of the thermal conductivity of a water-based single-wall carbon nanotube colloidal suspension with a modified 3- ω method
A modified 3-omega method applied to a suspended platinum microwire was employed to measure the thermal conductivity and convective heat transfer coefficient of a water-based single-walled carbon nanotube (CNT) solution (metallic single-wall nanotubes with 1.33 nm diameter and 1.14 wt% concentration), and an expression for calculating the convective heat transfer coefficient in such a free convective fluid was introduced. The measurement technique was validated for three model systems including vacuum, air and deionized water. It is found that there is excellent agreement between these three model systems with theoretical predictions. In addition, the frequency dependence on the third harmonic response measured in deionized water reveals the existence of a very low working frequency below 60 mHz. The thermal conductivity and convective heat transfer coefficient of the nanofluid (water-based single-wall CNT solution) were determined to be 0.73 +/- 0.013 W m(-1) K(-1) and 14 900 +/- 260 W m(-2) K(-1), respectively, which correspond to an enhancement of 19.4% in thermal conductivity and 18.9% in convective heat transfer as compared to water.
- 14 July 2009
- Published by IOP Publishing in Nanotechnology
- Vol. 20 (31) , 315706
Measurement of the thermal conductivity of a water-based single-wall carbon nanotube colloidal suspension with a modified 3- ω method
A modified 3-omega method applied to a suspended platinum microwire was employed to measure the thermal conductivity and convective heat transfer coefficient of a water-based single-walled carbon nanotube (CNT) solution (metallic single-wall nanotubes with 1.33 nm diameter and 1.14 wt% concentration), and an expression for calculating the convective heat transfer coefficient in such a free convective fluid was introduced. The measurement technique was validated for three model systems including vacuum, air and deionized water. It is found that there is excellent agreement between these three model systems with theoretical predictions. In addition, the frequency dependence on the third harmonic response measured in deionized water reveals the existence of a very low working frequency below 60 mHz. The thermal conductivity and convective heat transfer coefficient of the nanofluid (water-based single-wall CNT solution) were determined to be 0.73 +/- 0.013 W m(-1) K(-1) and 14 900 +/- 260 W m(-2) K(-1), respectively, which correspond to an enhancement of 19.4% in thermal conductivity and 18.9% in convective heat transfer as compared to water.
- 1 January 2008
- Published by ASME International
- p. 665-669
Electron and Focused Ion Beams in Thermal Science and Engineering
Focused-ion-beam (FIB) is a useful tool for defining nanoscale structures. High energy heavy ions inherently exhibit destructive nature. A less destructive tool has been devised by using electron beam. FIB is mainly considered as an etching tool, while electron beam can be used for deposition purpose. In this paper, both etching and deposition method are demonstrated for applications in thermal science. Thermal conductivity of nanostructures (such as carbon nanotubes) was measured by using the FIB (and electron beam) nanolithography technique. Boiling characteristics was studied in a submicron heater that could be fabricated by using FIB.
- 1 January 2008
- Published by ASME International
- p. 665-669
Electron and Focused Ion Beams in Thermal Science and Engineering
Focused-ion-beam (FIB) is a useful tool for defining nanoscale structures. High energy heavy ions inherently exhibit destructive nature. A less destructive tool has been devised by using electron beam. FIB is mainly considered as an etching tool, while electron beam can be used for deposition purpose. In this paper, both etching and deposition method are demonstrated for applications in thermal science. Thermal conductivity of nanostructures (such as carbon nanotubes) was measured by using the FIB (and electron beam) nanolithography technique. Boiling characteristics was studied in a submicron heater that could be fabricated by using FIB.