Robert J. Herfkens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert J. Herfkens has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Marcus T. Alley
Department of Radiology, Stanford University, Stanford, California, USA
2 shared publicationsMichael Markl
Department of Medical Physics, University Hospital, Albert‐Ludwigs‐University, Freiburg, Germany
2 shared publications- Norbert J. Pelc
Department of Radiology, Stanford University, Stanford, CA, USA
2 shared publications Ann Shimakawa
GE Medical Systems, Milwaukee, Wisconsin 53201
1 shared publication- Charles A. Taylor
Department of Mechanical Engineering, Stanford University, Stanford, California
1 shared publication - Christopher K. Zarins
Department of Surgery, Stanford University Medical Center, Stanford, CA 95305, USA
1 shared publication
Latest Publications
- 28 February 2009
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 20 (4) , 333-339
Technical Advances in Cardiovascular Imaging
- 28 February 2009
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 20 (4) , 333-339
Technical Advances in Cardiovascular Imaging
- Open Access
- 29 October 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1471-1479
Comparison of flow patterns in ascending aortic aneurysms and volunteers using four‐dimensional magnetic resonance velocity mapping
Purpose: To determine the difference in flow patterns between healthy volunteers and ascending aortic aneurysm patients using time‐resolved three‐dimensional (3D) phase contrast magnetic resonance velocity (4D‐flow) profiling.Materials and Methods: 4D‐flow was performed on 19 healthy volunteers and 13 patients with ascending aortic aneurysms. Vector fields placed on 2D planes were visually graded to analyze helical and retrograde flow patterns along the aortic arch. Quantitative analysis of the pulsatile flow was carried out on manually segmented planes.Results: In volunteers, flow progressed as follows: an initial jet of blood skewed toward the anterior right wall of the ascending aorta is reflected posterolaterally toward the inner curvature creating opposing helices, a right‐handed helix along the left wall and a left‐handed helix along the right wall; retrograde flow occurred in all volunteers along the inner curvature between the location of the two helices. In the aneurysm patients, the helices were larger; retrograde flow occurred earlier and lasted longer. The average velocity decreased between the ascending aorta and the transverse aorta in volunteers (47.9 mm/second decrease, P = 0.023), while in aneurysm patients the velocity increased (145 mm/second increase, P < 0.001).Conclusion: Dilation of the ascending aorta skews normal flow in the ascending aorta, changing retrograde and helical flow patterns. J. Magn. Reson. Imaging 2007.
- 29 October 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1471-1479
Open AccessComparison of flow patterns in ascending aortic aneurysms and volunteers using four‐dimensional magnetic resonance velocity mapping
Purpose: To determine the difference in flow patterns between healthy volunteers and ascending aortic aneurysm patients using time‐resolved three‐dimensional (3D) phase contrast magnetic resonance velocity (4D‐flow) profiling.Materials and Methods: 4D‐flow was performed on 19 healthy volunteers and 13 patients with ascending aortic aneurysms. Vector fields placed on 2D planes were visually graded to analyze helical and retrograde flow patterns along the aortic arch. Quantitative analysis of the pulsatile flow was carried out on manually segmented planes.Results: In volunteers, flow progressed as follows: an initial jet of blood skewed toward the anterior right wall of the ascending aorta is reflected posterolaterally toward the inner curvature creating opposing helices, a right‐handed helix along the left wall and a left‐handed helix along the right wall; retrograde flow occurred in all volunteers along the inner curvature between the location of the two helices. In the aneurysm patients, the helices were larger; retrograde flow occurred earlier and lasted longer. The average velocity decreased between the ascending aorta and the transverse aorta in volunteers (47.9 mm/second decrease, P = 0.023), while in aneurysm patients the velocity increased (145 mm/second increase, P < 0.001).Conclusion: Dilation of the ascending aorta skews normal flow in the ascending aorta, changing retrograde and helical flow patterns. J. Magn. Reson. Imaging 2007.
- Open Access
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 286-295
Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: In vivo validation in the porcine aorta
Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity‐based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC‐MRI and an implanted coil and were then time‐integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity‐based and marker‐based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly. Magn Reson Med 52:286–295, 2004.
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 286-295
Open AccessQuantification of vessel wall motion and cyclic strain using cine phase contrast MRI: In vivo validation in the porcine aorta
Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity‐based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC‐MRI and an implanted coil and were then time‐integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity‐based and marker‐based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly. Magn Reson Med 52:286–295, 2004.
- Open Access
- 29 June 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 109 (25) , 3221-3222
Four-Dimensional Magnetic Resonance Velocity Mapping in a Healthy Volunteer With Pseudocoarctation of the Thoracic Aorta
F our-dimensional (4D) velocity mapping technology is used here to evaluate blood flow patterns associated with an incidentally noted, non-hemodynamically significant pseudocoarctation of the proximal descending thoracic aorta in a healthy volunteer (Figure). The 4D phase-contrast magnetic resonance (MR) velocity mapping using timeresolved, cardiac-gated 3-dimensional (3D) velocity data allows for visualization of complex multidimensional blood flow with complete spatial and temporal registration of the region of interest. Four-dimensional velocity mapping is a reliable technique for the analysis and visualization of normal and pathological blood flow features throughout the thoracic aorta. The 4D nature of the data set affords a variety of post-processing options. One visualization technique that has been developed for interpretation of 4D MR data sets is referred to as streamlines. These imaginary lines are aligned with local vector fields and represent the flow field at any given moment throughout the cardiac cycle. Streamlines originate from points on a 2-dimensional grid plane that is arbitrarily positioned within the imaging volume. From the Departments of Radiology (M.
- 29 June 2004
- Published by Wolters Kluwer Health in Circulation
- Vol. 109 (25) , 3221-3222
Open AccessFour-Dimensional Magnetic Resonance Velocity Mapping in a Healthy Volunteer With Pseudocoarctation of the Thoracic Aorta
F our-dimensional (4D) velocity mapping technology is used here to evaluate blood flow patterns associated with an incidentally noted, non-hemodynamically significant pseudocoarctation of the proximal descending thoracic aorta in a healthy volunteer (Figure). The 4D phase-contrast magnetic resonance (MR) velocity mapping using timeresolved, cardiac-gated 3-dimensional (3D) velocity data allows for visualization of complex multidimensional blood flow with complete spatial and temporal registration of the region of interest. Four-dimensional velocity mapping is a reliable technique for the analysis and visualization of normal and pathological blood flow features throughout the thoracic aorta. The 4D nature of the data set affords a variety of post-processing options. One visualization technique that has been developed for interpretation of 4D MR data sets is referred to as streamlines. These imaginary lines are aligned with local vector fields and represent the flow field at any given moment throughout the cardiac cycle. Streamlines originate from points on a 2-dimensional grid plane that is arbitrarily positioned within the imaging volume. From the Departments of Radiology (M.
- Open Access
- 7 May 1999
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 9 (5) , 751-755
Fast 3D Cardiac Cine MR Imaging
- 7 May 1999
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 9 (5) , 751-755
Open AccessFast 3D Cardiac Cine MR Imaging