Kurt D. Benkstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kurt D. Benkstein has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Sean E. Lehman
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publications - Steve Semancik
Biomolecular Measurement Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
3 shared publications - Wyatt N. Vreeland
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publications B. Raman
Department of Biomedical Engineering, Washington University, St. Louis, MO 63130, USA
2 shared publications- David L. Lahr
Foghorn Therapeutics (United States) 12
2 shared publications - Lili Wang
Biosystems and Biomaterials Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), United States
2 shared publications
Latest Publications
- Open Access
Surface Functionalization Studies in the Development of Nanohole Plasmonic Sensors
Localized surface plasmon resonance (LSPR) is an optical phenomenon that occurs when light interacts with free electrons on the surface of metallic thin films, producing intensified electromagnetic fields at specific sites, often called “hot spots”. LSPR-based sensing technologies respond to chemical and associated optical interfacial changes. Inherent advantages include enhanced sensitivity, compact size, low production cost, and strong potential for integration into portable, point-of-care diagnostic systems. This study focuses on a detailed investigation into the surface functionalization of localized surface plasmon resonance (LSPR)-based nanohole array (NHA) sensors for biomedical applications. Gold-coated NHA surfaces were functionalized using polyethylene glycol (PEG) self-assembled monolayers (SAMs), enabling specific attachment of biomolecular species. As a proof-of-concept, bovine serum albumin (BSA) and SARS-CoV-2 nanobody proteins were successfully immobilized on the PEGylated surfaces. Individual steps of surface modification including PEGylation, protein immobilization and nanobody immobilization were validated through a dual-method approach which combined measurement of LSPR optical spectral shifts and x-ray photoelectron spectroscopy (XPS) chemical analyses. Reproducibility was assessed across multiple sensors and repeated trials, confirming the repeatability of each functionalization and binding process. The sensor system, consisting of NHA-based plasmonic platform, microfluidics, and a portable optical spectrometer, exhibits the capability for reliable and sensitive, label-free detection of biomolecular targets, including viral antigens, in liquid-phase environments.
Open AccessSurface Functionalization Studies in the Development of Nanohole Plasmonic Sensors
Localized surface plasmon resonance (LSPR) is an optical phenomenon that occurs when light interacts with free electrons on the surface of metallic thin films, producing intensified electromagnetic fields at specific sites, often called “hot spots”. LSPR-based sensing technologies respond to chemical and associated optical interfacial changes. Inherent advantages include enhanced sensitivity, compact size, low production cost, and strong potential for integration into portable, point-of-care diagnostic systems. This study focuses on a detailed investigation into the surface functionalization of localized surface plasmon resonance (LSPR)-based nanohole array (NHA) sensors for biomedical applications. Gold-coated NHA surfaces were functionalized using polyethylene glycol (PEG) self-assembled monolayers (SAMs), enabling specific attachment of biomolecular species. As a proof-of-concept, bovine serum albumin (BSA) and SARS-CoV-2 nanobody proteins were successfully immobilized on the PEGylated surfaces. Individual steps of surface modification including PEGylation, protein immobilization and nanobody immobilization were validated through a dual-method approach which combined measurement of LSPR optical spectral shifts and x-ray photoelectron spectroscopy (XPS) chemical analyses. Reproducibility was assessed across multiple sensors and repeated trials, confirming the repeatability of each functionalization and binding process. The sensor system, consisting of NHA-based plasmonic platform, microfluidics, and a portable optical spectrometer, exhibits the capability for reliable and sensitive, label-free detection of biomolecular targets, including viral antigens, in liquid-phase environments.
- Open Access
- 31 December 2025
- Published by MDPI AG in Biomolecules
- Vol. 16 (1) , 66
Intermethod Characterization of Commercially Available Extracellular Vesicles as Reference Materials
The National Institute of Standards and Technology (NIST) is developing analytical methods to characterize extracellular vesicles (EVs) to support the urgent need for standardized EV reference materials (RMs). This study used orthogonal techniques, cryogenic electron microscopy (Cryo-EM), particle tracking analysis (PTA), asymmetrical flow field-flow fractionation (AF4), and microfluidic resistive pulse sensing (MRPS), to evaluate particle size distributions (PSDs) and particle number concentrations (PNCs) of human mesenchymal stem cells (MSCs) and LNCaP prostate cancer cell EVs. Proteomic profiles were assessed by mass spectrometry (MS), and microRNA (miRNA) content of LNCaP EVs was evaluated by small RNA-seq at two independent laboratories. A commercial green fluorescent protein exosome served as a control, except in Cryo-EM, proteomic, and miRNA analyses. Cryo-EM, regarded as the gold standard for morphological resolution, served as PSD reference. PSDs from all methods skewed larger than Cryo-EM, with MRPS closest, AF4 most divergent, and PTA intermediate with broader distributions. All techniques reported broad PSDs (30 nm to >350 nm) with PNCs decreasing with increasing particle size, except for AF4. Quantitative discrepancies in PNCs reached up to two orders of magnitude across methods and cell sources. MS identified global and EV-specific proteins, including syntenin-1 and tetraspanins CD9, CD63, and CD81. RNA-seq revealed notable inter-laboratory variation. These findings highlight the variability across measurement platforms and emphasize the need for reproducible methods to support NIST’s mission of developing reliable EV reference materials.
- 31 December 2025
- Published by MDPI AG in Biomolecules
- Vol. 16 (1) , 66
Open AccessIntermethod Characterization of Commercially Available Extracellular Vesicles as Reference Materials
The National Institute of Standards and Technology (NIST) is developing analytical methods to characterize extracellular vesicles (EVs) to support the urgent need for standardized EV reference materials (RMs). This study used orthogonal techniques, cryogenic electron microscopy (Cryo-EM), particle tracking analysis (PTA), asymmetrical flow field-flow fractionation (AF4), and microfluidic resistive pulse sensing (MRPS), to evaluate particle size distributions (PSDs) and particle number concentrations (PNCs) of human mesenchymal stem cells (MSCs) and LNCaP prostate cancer cell EVs. Proteomic profiles were assessed by mass spectrometry (MS), and microRNA (miRNA) content of LNCaP EVs was evaluated by small RNA-seq at two independent laboratories. A commercial green fluorescent protein exosome served as a control, except in Cryo-EM, proteomic, and miRNA analyses. Cryo-EM, regarded as the gold standard for morphological resolution, served as PSD reference. PSDs from all methods skewed larger than Cryo-EM, with MRPS closest, AF4 most divergent, and PTA intermediate with broader distributions. All techniques reported broad PSDs (30 nm to >350 nm) with PNCs decreasing with increasing particle size, except for AF4. Quantitative discrepancies in PNCs reached up to two orders of magnitude across methods and cell sources. MS identified global and EV-specific proteins, including syntenin-1 and tetraspanins CD9, CD63, and CD81. RNA-seq revealed notable inter-laboratory variation. These findings highlight the variability across measurement platforms and emphasize the need for reproducible methods to support NIST’s mission of developing reliable EV reference materials.
- 14 December 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 403, 135152
Picoliter drop deposition of SnO2 nanoparticles onto microsensor platforms
- 14 December 2023
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 403, 135152
Picoliter drop deposition of SnO2 nanoparticles onto microsensor platforms
- Open Access
- 21 August 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (35) , 12313-12323
Particle Metrology Approach to Understanding How Storage Conditions Affect Long-Term Liposome Stability
Lipid nanoparticles are a generic type of nanomaterial with broad applicability in medicine as drug delivery vehicles. Liposomes are a subtype of lipid nanoparticles and, as a therapeutic platform, can be loaded with a genetic material or pharmaceutical agents for use as drug treatments. An open question for these types of lipid nanoparticles is what factor(s) affect the long-term stability of the particles. The stability of the particle is of great interest to understand and predict the effective shelf-life and storage requirements. In this report, we detail a one-year study of liposome stability as a function of lipid composition, buffer composition/pH, and storage temperature. This was done in aqueous solution without freezing. The effect of lipid composition is shown to be a critical factor when evaluating stability of the measured particle size and number concentration. Other factors (i.e., storage temperature and buffer pH/composition) were shown to be less critical but still have some effect. The stability of these particles informs formulation and optimal storage requirements and assists with future developmental planning of a NIST liposome-based reference material. This work also highlights the complex nature of long-term soft particle storage in biopharmaceutical applications.
- 21 August 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (35) , 12313-12323
Open AccessParticle Metrology Approach to Understanding How Storage Conditions Affect Long-Term Liposome Stability
Lipid nanoparticles are a generic type of nanomaterial with broad applicability in medicine as drug delivery vehicles. Liposomes are a subtype of lipid nanoparticles and, as a therapeutic platform, can be loaded with a genetic material or pharmaceutical agents for use as drug treatments. An open question for these types of lipid nanoparticles is what factor(s) affect the long-term stability of the particles. The stability of the particle is of great interest to understand and predict the effective shelf-life and storage requirements. In this report, we detail a one-year study of liposome stability as a function of lipid composition, buffer composition/pH, and storage temperature. This was done in aqueous solution without freezing. The effect of lipid composition is shown to be a critical factor when evaluating stability of the measured particle size and number concentration. Other factors (i.e., storage temperature and buffer pH/composition) were shown to be less critical but still have some effect. The stability of these particles informs formulation and optimal storage requirements and assists with future developmental planning of a NIST liposome-based reference material. This work also highlights the complex nature of long-term soft particle storage in biopharmaceutical applications.
- 23 November 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (49) , 54411-54422
Deep Learning Image Analysis of Nanoplasmonic Sensors: Toward Medical Breath Monitoring
Sensing biomarkers in exhaled breath offers a potentially portable, cost-effective, and noninvasive strategy for disease diagnosis screening and monitoring, while high sensitivity, wide sensing range, and target specificity are critical challenges. We demonstrate a deep learning-assisted plasmonic sensing platform that can detect and quantify gas-phase biomarkers in breath-related backgrounds of varying complexity. The sensing interface consisted of Au/SiO2 nanopillars covered with a 15 nm metal-organic framework. A small camera was utilized to capture the plasmonic sensing responses as images, which were subjected to deep learning signal processing. The approach has been demonstrated at a classification accuracy of 95 to 98% for the diabetic ketosis marker acetone within a concentration range of 0.5-80 μmol/mol. The reported work provides a thorough exploration of single-sensor capabilities and sets the basis for more advanced utilization of artificial intelligence in sensing applications.
- 23 November 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (49) , 54411-54422
Deep Learning Image Analysis of Nanoplasmonic Sensors: Toward Medical Breath Monitoring
Sensing biomarkers in exhaled breath offers a potentially portable, cost-effective, and noninvasive strategy for disease diagnosis screening and monitoring, while high sensitivity, wide sensing range, and target specificity are critical challenges. We demonstrate a deep learning-assisted plasmonic sensing platform that can detect and quantify gas-phase biomarkers in breath-related backgrounds of varying complexity. The sensing interface consisted of Au/SiO2 nanopillars covered with a 15 nm metal-organic framework. A small camera was utilized to capture the plasmonic sensing responses as images, which were subjected to deep learning signal processing. The approach has been demonstrated at a classification accuracy of 95 to 98% for the diabetic ketosis marker acetone within a concentration range of 0.5-80 μmol/mol. The reported work provides a thorough exploration of single-sensor capabilities and sets the basis for more advanced utilization of artificial intelligence in sensing applications.
- Open Access
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Number Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.
- 8 September 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Open AccessNumber Concentration Measurements of Polystyrene Submicrometer Particles
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.
- 1 March 2022
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 111 (3) , 699-709
An Interlaboratory Comparison on the Characterization of a Sub-micrometer Polydisperse Particle Dispersion
- 1 March 2022
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 111 (3) , 699-709
An Interlaboratory Comparison on the Characterization of a Sub-micrometer Polydisperse Particle Dispersion
- Open Access
Plasmonic Sensing Studies of a Gas-Phase Cystic Fibrosis Marker in Moisture Laden Air
A plasmonic sensing platform was developed as a noninvasive method to monitor gas-phase biomarkers related to cystic fibrosis (CF). The nanohole array (NHA) sensing platform is based on localized surface plasmon resonance (LSPR) and offers a rapid data acquisition capability. Among the numerous gas-phase biomarkers that can be used to assess the lung health of CF patients, acetaldehyde was selected for this investigation. Previous research with diverse types of sensing platforms, with materials ranging from metal oxides to 2-D materials, detected gas-phase acetaldehyde with the lowest detection limit at the µmol/mol (parts-per-million (ppm)) level. In contrast, this work presents a plasmonic sensing platform that can approach the nmol/mol (parts-per-billion (ppb)) level, which covers the required concentration range needed to monitor the status of lung infection and find pulmonary exacerbations. During the experimental measurements made by a spectrometer and by a smartphone, the sensing examination was initially performed in a dry air background and then with high relative humidity (RH) as an interferent, which is relevant to exhaled breath. At a room temperature of 23.1 °C, the lowest detection limit for the investigated plasmonic sensing platform under dry air and 72% RH conditions are 250 nmol/mol (ppb) and 1000 nmol/mol (ppb), respectively.
Open AccessPlasmonic Sensing Studies of a Gas-Phase Cystic Fibrosis Marker in Moisture Laden Air
A plasmonic sensing platform was developed as a noninvasive method to monitor gas-phase biomarkers related to cystic fibrosis (CF). The nanohole array (NHA) sensing platform is based on localized surface plasmon resonance (LSPR) and offers a rapid data acquisition capability. Among the numerous gas-phase biomarkers that can be used to assess the lung health of CF patients, acetaldehyde was selected for this investigation. Previous research with diverse types of sensing platforms, with materials ranging from metal oxides to 2-D materials, detected gas-phase acetaldehyde with the lowest detection limit at the µmol/mol (parts-per-million (ppm)) level. In contrast, this work presents a plasmonic sensing platform that can approach the nmol/mol (parts-per-billion (ppb)) level, which covers the required concentration range needed to monitor the status of lung infection and find pulmonary exacerbations. During the experimental measurements made by a spectrometer and by a smartphone, the sensing examination was initially performed in a dry air background and then with high relative humidity (RH) as an interferent, which is relevant to exhaled breath. At a room temperature of 23.1 °C, the lowest detection limit for the investigated plasmonic sensing platform under dry air and 72% RH conditions are 250 nmol/mol (ppb) and 1000 nmol/mol (ppb), respectively.
- Open Access
- 25 July 2019
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 46 (11) , 1469-1478
Evaluating changes to Ralstonia pickettii in high-purity water to guide selection of potential calibration materials for online water bioburden analyzers
Online water bioburden analyzers (OWBAs) can provide real-time feedback on viable bacteria in high-purity water (HPW) systems for pharmaceutical manufacturers. To calibrate and validate OWBAs, which detect bacteria using scattered light and bacterial autofluorescence, standards are needed that mimic the characteristics of bacteria in HPW. To guide selection of potential standards, e.g., fluorescent microspheres, a relevant bacterial contaminant, Ralstonia pickettii, was characterized for size, count, viability, and autofluorescence after exposure for 24 h to HPW or a nutrient environment. The cells exposed to HPW showed smaller sizes, with lower counts and autofluorescence intensities, but similar spectral features. The cell characteristics are discussed in comparison with a set of fluorescent microspheres, considering factors relevant to OWBAs. These studies suggest that fluorescent microspheres should be relatively small (< 1 µm diameter) and dim, while covering a broad emission range from ≈ (420 to 600) nm to best mimic the representative R. pickettii.
- 25 July 2019
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 46 (11) , 1469-1478
Open AccessEvaluating changes to Ralstonia pickettii in high-purity water to guide selection of potential calibration materials for online water bioburden analyzers
Online water bioburden analyzers (OWBAs) can provide real-time feedback on viable bacteria in high-purity water (HPW) systems for pharmaceutical manufacturers. To calibrate and validate OWBAs, which detect bacteria using scattered light and bacterial autofluorescence, standards are needed that mimic the characteristics of bacteria in HPW. To guide selection of potential standards, e.g., fluorescent microspheres, a relevant bacterial contaminant, Ralstonia pickettii, was characterized for size, count, viability, and autofluorescence after exposure for 24 h to HPW or a nutrient environment. The cells exposed to HPW showed smaller sizes, with lower counts and autofluorescence intensities, but similar spectral features. The cell characteristics are discussed in comparison with a set of fluorescent microspheres, considering factors relevant to OWBAs. These studies suggest that fluorescent microspheres should be relatively small (< 1 µm diameter) and dim, while covering a broad emission range from ≈ (420 to 600) nm to best mimic the representative R. pickettii.
- 6 March 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 197, 280-291
Analytical capabilities of chemiresistive microsensor arrays in a simulated Martian atmosphere
- 6 March 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 197, 280-291
Analytical capabilities of chemiresistive microsensor arrays in a simulated Martian atmosphere