Number Concentration Measurements of Polystyrene Submicrometer Particles
Authors:
- Paul C. DeRosePDPaul C. DeRose
- Kurt D. BenksteinKBKurt D. Benkstein
- Elzafir B. ElsheikhEEElzafir B. Elsheikh
- Adolfas K. GaigalasAGAdolfas K. Gaigalas
- Sean E. LehmanSLSean E. Lehman
- Dean C. RippleDRDean C. Ripple
- Linhua TianLTLinhua Tian
- Wyatt N. VreelandWVWyatt N. Vreeland
- Eric J. WelchEWEric J. Welch
- Adam W. YorkAYAdam W. York
- Yu-Zhong ZhangYZYu-Zhong Zhang
- Lili WangLWLili Wang
Open Access
- 8 September 2022
- journal article
- research article
- Published by MDPI AG in Nanomaterials
- Vol. 12 (18) , 3118
Abstract
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.Keywords
Funding Information
- U.S. Government
This publication has 29 references indexed in Scilit:
- Data-analysis strategies for image-based cell profilingNature Methods, 2017
- Validation of a particle tracking analysis method for the size determination of nano- and microparticlesJournal of Nanoparticle Research, 2017
- Consensus building for interlaboratory studies, key comparisons, and meta-analysisMetrologia, 2017
- Evaluation of ViroCyt® Virus Counter for Rapid Filovirus QuantitationViruses, 2015
- Quantification of cells with specific phenotypes I: Determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti‐CD4 FITC antibodyCytometry Part A, 2015
- Sorting of small infectious virus particles by flow virometry reveals distinct infectivity profilesNature Communications, 2015
- Fiji: an open-source platform for biological-image analysisNature Methods, 2012
- A high-throughput label-free nanoparticle analyserNature Nanotechnology, 2011
- Primary standard for the number concentration of liquid-borne particles in the 10 to 20 µm diameter rangeMeasurement Science and Technology, 2010
- Submicrometer Particle Sizing by Multiangle Light Scattering following FractionationJournal of Colloid and Interface Science, 1998