Karl Vollmers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karl Vollmers has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bradley J. Nelson
Multi-Scale Robotics Lab, ETH Zurich, Zurich, Switzerland
2 shared publications - Jake J. Abbott
Institute of Robotics and Intelligent Systems, ETH Zurich, 8092 Zurich, Switzerland
1 shared publication - K. Berk Yesin
Institute of Robotics and Intelligent Systems, ETH Zurich, 8092 Zurich, Switzerland
1 shared publication - Michael P. Kummer
Institute of Robotics and Intelligent Systems, ETH Zurich, 8092 Zurich, Switzerland
1 shared publication
Latest Publications
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 1122-1127
Measuring the Magnetic and Hydrodynamic Properties of Assembled-MEMS Microrobots
Microrobots experience physical phenomena that are difficult to model analytically and that are not completely captured with macro-scale prototypes. In this paper we present a reconfigurable robotic measurement system to characterize the magnetic and hydrodynamic properties of assembled-MEMS microrobots. The system consists of a powerful permanent magnet that is position controlled with a linear stage. The magnetic field is accurately characterized. Precision sensors are used to measure magnetic force as a function of applied field. The system is first used to validate an existing model for the magnetic force on a soft-magnetic ellipsoid. Next, the magnetic force on a soft-magnetic assembled-MEMS microrobot as a function of the applied field is measured experimentally. Finally, a vision tracking system is integrated with the setup to measure the hydrodynamic properties of the microrobot. The coefficient of viscous friction for the microrobot is obtained experimentally.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 1122-1127
Measuring the Magnetic and Hydrodynamic Properties of Assembled-MEMS Microrobots
Microrobots experience physical phenomena that are difficult to model analytically and that are not completely captured with macro-scale prototypes. In this paper we present a reconfigurable robotic measurement system to characterize the magnetic and hydrodynamic properties of assembled-MEMS microrobots. The system consists of a powerful permanent magnet that is position controlled with a linear stage. The magnetic field is accurately characterized. Precision sensors are used to measure magnetic force as a function of applied field. The system is first used to validate an existing model for the magnetic force on a soft-magnetic ellipsoid. Next, the magnetic force on a soft-magnetic assembled-MEMS microrobot as a function of the applied field is measured experimentally. Finally, a vision tracking system is integrated with the setup to measure the hydrodynamic properties of the microrobot. The coefficient of viscous friction for the microrobot is obtained experimentally.
- Top Cited Papers
- 1 May 2006
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 25 (5-6) , 527-536
Modeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields
This paper investigates fundamental design, modeling, and control issues related to untethered biomedical microrobots guided inside the human body through external magnetic fields. Proposed areas of application for these microrobots include sensing, diagnosis, and surgical procedures in intraocular, cardiovascular, and inner-ear environments. A prototype microrobot and steering system are introduced. Fluid drag experiments performed on the prototype robot show that the 950 × 400 μm elliptical shape has a spherical equivalent diameter of 477 μm. Drag forces combined with saturation magnetization (5 × 10 5 A/m) of the prototype indicate that the required magnetic field gradients for application inside the vitreous humor and blood vessels are on the order of 0.7T/m.
- 1 May 2006
- Published by SAGE Publications in The International Journal of Robotics Research
- Vol. 25 (5-6) , 527-536
Top Cited PapersModeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields
This paper investigates fundamental design, modeling, and control issues related to untethered biomedical microrobots guided inside the human body through external magnetic fields. Proposed areas of application for these microrobots include sensing, diagnosis, and surgical procedures in intraocular, cardiovascular, and inner-ear environments. A prototype microrobot and steering system are introduced. Fluid drag experiments performed on the prototype robot show that the 950 × 400 μm elliptical shape has a spherical equivalent diameter of 477 μm. Drag forces combined with saturation magnetization (5 × 10 5 A/m) of the prototype indicate that the required magnetic field gradients for application inside the vitreous humor and blood vessels are on the order of 0.7T/m.