Michael P. Kummer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael P. Kummer has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bradley J. Nelson
Multi-Scale Robotics Lab, ETH Zurich, Zurich, Switzerland
2 shared publications - Jake J. Abbott
Institute of Robotics and Intelligent Systems, ETH Zurich, 8092 Zurich, Switzerland
2 shared publications - Karl Vollmers
Institute of Robotics and Intelligent Systems, ETH Zurich, 8092 Zurich, Switzerland
1 shared publication - Sandro Dinser
Institute for Mechanical Systems, ETH Zurich, 8092 Zurich, Switzerland
1 shared publication
Latest Publications
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 6406-6409
Artificial Vitreous Humor for In Vitro Experiments
In this paper we present a protocol to create artificial vitreous humor phantom tissue to be used as a test bed for in vitro experiments. The artificial vitreous consists of water, agar, and hyaluronic acid. Unlike existing vitreous replacement substances, this dummy tissue exhibits viscoelastic characteristics of in vivo natural vitreous humor. We are able to prepare artificial vitreous with a range of viscoelastic properties, which will allow us to account for the variation seen in human vitreous that comes with aging. The artificial vitreous will primarily serve as an experimental test bed for wireless magnetic control and vision-based tracking of assembled-MEMS microrobots. These microrobots will someday enable minimally invasive surgical and diagnostic intraocular procedures.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 6406-6409
Artificial Vitreous Humor for In Vitro Experiments
In this paper we present a protocol to create artificial vitreous humor phantom tissue to be used as a test bed for in vitro experiments. The artificial vitreous consists of water, agar, and hyaluronic acid. Unlike existing vitreous replacement substances, this dummy tissue exhibits viscoelastic characteristics of in vivo natural vitreous humor. We are able to prepare artificial vitreous with a range of viscoelastic properties, which will allow us to account for the variation seen in human vitreous that comes with aging. The artificial vitreous will primarily serve as an experimental test bed for wireless magnetic control and vision-based tracking of assembled-MEMS microrobots. These microrobots will someday enable minimally invasive surgical and diagnostic intraocular procedures.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 1122-1127
Measuring the Magnetic and Hydrodynamic Properties of Assembled-MEMS Microrobots
Microrobots experience physical phenomena that are difficult to model analytically and that are not completely captured with macro-scale prototypes. In this paper we present a reconfigurable robotic measurement system to characterize the magnetic and hydrodynamic properties of assembled-MEMS microrobots. The system consists of a powerful permanent magnet that is position controlled with a linear stage. The magnetic field is accurately characterized. Precision sensors are used to measure magnetic force as a function of applied field. The system is first used to validate an existing model for the magnetic force on a soft-magnetic ellipsoid. Next, the magnetic force on a soft-magnetic assembled-MEMS microrobot as a function of the applied field is measured experimentally. Finally, a vision tracking system is integrated with the setup to measure the hydrodynamic properties of the microrobot. The coefficient of viscous friction for the microrobot is obtained experimentally.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 1122-1127
Measuring the Magnetic and Hydrodynamic Properties of Assembled-MEMS Microrobots
Microrobots experience physical phenomena that are difficult to model analytically and that are not completely captured with macro-scale prototypes. In this paper we present a reconfigurable robotic measurement system to characterize the magnetic and hydrodynamic properties of assembled-MEMS microrobots. The system consists of a powerful permanent magnet that is position controlled with a linear stage. The magnetic field is accurately characterized. Precision sensors are used to measure magnetic force as a function of applied field. The system is first used to validate an existing model for the magnetic force on a soft-magnetic ellipsoid. Next, the magnetic force on a soft-magnetic assembled-MEMS microrobot as a function of the applied field is measured experimentally. Finally, a vision tracking system is integrated with the setup to measure the hydrodynamic properties of the microrobot. The coefficient of viscous friction for the microrobot is obtained experimentally.