Christopher P. Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher P. Cheng has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Ga-Young Suh
Department of Biomedical Engineering, California State University, Long Beach, CA, USA
16 shared publications - Johan Bondesson
Division of Vascular Surgery, Department of Surgery, Stanford University, Stanford, California
9 shared publications - Brant W. Ullery
Providence Heart and Vascular Institute, Portland, Ore
4 shared publications Charles A. Taylor
Department of Surgery, Stanford University, Stanford, CA
4 shared publicationsJason T. Lee
Division of Vascular Surgery, Stanford University, Stanford, CA, USA
4 shared publicationsRobert J. Herfkens
Department of Radiology, Stanford University, Stanford, CA
4 shared publications
Latest Publications
- Open Access
- 27 June 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (6) , 102569
Automated CT Quantification of Iliofemoral Venous Arc Length Demonstrates Left-Sided Predominance and Sex-Specific Variation
- 27 June 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (6) , 102569
Open AccessAutomated CT Quantification of Iliofemoral Venous Arc Length Demonstrates Left-Sided Predominance and Sex-Specific Variation
- Open Access
- 23 June 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (5) , 102363
Aortic Remodeling after TEVAR and PETTICOAT to Treat Complicated Type B Aortic Dissection
- 23 June 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (5) , 102363
Open AccessAortic Remodeling after TEVAR and PETTICOAT to Treat Complicated Type B Aortic Dissection
- 13 May 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (5) , 2439-2448
Impacts of Thoracic Endovascular Aortic Repair and Thrombus Load on Aortic Radial Deformation
Purpose: Aortic stiffness and intraluminal thrombus at baseline have been suggested as potential determinants of the impact of aortic endovascular devices on aortic wall properties. We aim to assess the impact of the endograft and of thrombus load on aortic compliance through the assessment of changes in aortic radial deformation following thoracic endovascular aortic repair (TEVAR). Materials and Methods: The 3D geometric models of the aorta at peak systole and end diastole were constructed from both pre- and post-TEVAR 4D flow magnetic resonance imaging (MRI) of aortic aneurysm and dissection patients. Arclength, length-averaged curvature, and true- and whole lumen effective diameters and areas were assessed in different aortic segments (ascending aorta, endografted segment, and all aorta). Aortic radial deformation was defined as percentage change in aortic diameter from diastole to systole. Thrombus load was defined as thrombus volume divided by aortic volume. Spearman’s coefficient (R) was calculated to assess linear correlations. Results: The analysis was conducted on 14 patients/TEVAR procedures (n=7 aneurysms, n=7 dissections). Median time between pre- and postoperative MRI was 124.6 ± 81.7 days. Aortic radial deformation significantly decreased in the endografted segment (7.2% ± 3.6% vs 5.0% ± 2.0%, p2 =0.64), and in an even more significant manner when excluding the 2 patients with a history of prosthetic ascending aorta replacement (R=−0.88, R 2 =0.77). Conclusion: Following TEVAR, aortic radial deformation, is reduced in the stented segment and amplified in the ascending aorta. Greater baseline thrombus load results in lower radial deformation amplification post-TEVAR. These findings highlight the benefit of thrombus load assessment pre-TEVAR and the need for increasing the compliance of future grafts to minimize its impact. Clinical Impact: Following thoracic endovascular aortic repair (TEVAR), aortic radial deformation, directly related to aortic compliance, is reduced in the stented segment, and amplified upstream in the ascending aorta, likely due to increased stiffness of the endograft, remodeling, and pressure pulse reflection. Thrombus load is found as an effective predictor of aortic radial deformation amplification following TEVAR. This highlights the benefit of thrombus assessment pre-TEVAR and the need for increasing compliance of future graft designs to minimize its impact.
- 13 May 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (5) , 2439-2448
Impacts of Thoracic Endovascular Aortic Repair and Thrombus Load on Aortic Radial Deformation
Purpose: Aortic stiffness and intraluminal thrombus at baseline have been suggested as potential determinants of the impact of aortic endovascular devices on aortic wall properties. We aim to assess the impact of the endograft and of thrombus load on aortic compliance through the assessment of changes in aortic radial deformation following thoracic endovascular aortic repair (TEVAR). Materials and Methods: The 3D geometric models of the aorta at peak systole and end diastole were constructed from both pre- and post-TEVAR 4D flow magnetic resonance imaging (MRI) of aortic aneurysm and dissection patients. Arclength, length-averaged curvature, and true- and whole lumen effective diameters and areas were assessed in different aortic segments (ascending aorta, endografted segment, and all aorta). Aortic radial deformation was defined as percentage change in aortic diameter from diastole to systole. Thrombus load was defined as thrombus volume divided by aortic volume. Spearman’s coefficient (R) was calculated to assess linear correlations. Results: The analysis was conducted on 14 patients/TEVAR procedures (n=7 aneurysms, n=7 dissections). Median time between pre- and postoperative MRI was 124.6 ± 81.7 days. Aortic radial deformation significantly decreased in the endografted segment (7.2% ± 3.6% vs 5.0% ± 2.0%, p2 =0.64), and in an even more significant manner when excluding the 2 patients with a history of prosthetic ascending aorta replacement (R=−0.88, R 2 =0.77). Conclusion: Following TEVAR, aortic radial deformation, is reduced in the stented segment and amplified in the ascending aorta. Greater baseline thrombus load results in lower radial deformation amplification post-TEVAR. These findings highlight the benefit of thrombus load assessment pre-TEVAR and the need for increasing the compliance of future grafts to minimize its impact. Clinical Impact: Following thoracic endovascular aortic repair (TEVAR), aortic radial deformation, directly related to aortic compliance, is reduced in the stented segment, and amplified upstream in the ascending aorta, likely due to increased stiffness of the endograft, remodeling, and pressure pulse reflection. Thrombus load is found as an effective predictor of aortic radial deformation amplification following TEVAR. This highlights the benefit of thrombus assessment pre-TEVAR and the need for increasing compliance of future graft designs to minimize its impact.
- Open Access
- 23 January 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102522
Tibial Artery Stent Deformations From Ankle Plantarflexion and Dorsiflexion, Knee Flexion, and Simulated Calf Muscle Contraction
- 23 January 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102522
Open AccessTibial Artery Stent Deformations From Ankle Plantarflexion and Dorsiflexion, Knee Flexion, and Simulated Calf Muscle Contraction
- 20 November 2024
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 80 (6) , A1895
Fatigue Test Method to Evaluate the 50 Year Durability of Venous Stents
- 20 November 2024
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 80 (6) , A1895
Fatigue Test Method to Evaluate the 50 Year Durability of Venous Stents
- Open Access
- 19 June 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (4) , 521-528
Fatigue Test Method to Evaluate the 50 Year Durability of Venous Stents
- 19 June 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (4) , 521-528
Open AccessFatigue Test Method to Evaluate the 50 Year Durability of Venous Stents
- Open Access
- 15 September 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (6) , 101134
Impact of Stenting on PDA Length, Curvature, and Pulsatile Deformations Based on CT Assessment
- 15 September 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (6) , 101134
Open AccessImpact of Stenting on PDA Length, Curvature, and Pulsatile Deformations Based on CT Assessment
- 24 July 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (3) , 653-659
Pulsatile Deformations of a Conformable Descending Thoracic Aortic Endograft in Aneurysm, Dissection, and Blunt Traumatic Aortic Injury Patients
Purpose: This study presents analytic techniques to quantify cardiac pulsatility-induced deformations of thoracic aortic endografts in patients with thoracic aortic aneurysm (TAA), dissection (TAD), and blunt thoracic aortic injury (BTAI) after thoracic endovascular aortic repair (TEVAR). Technique: We analyzed 19 image data sets from 14 patients treated for TAA, TAD, and BTAI with cardiac-gated post-TEVAR CTs. Systolic and diastolic geometric models were constructed and diametric, axial, and bending deformations were quantified. For patients with cardiac-gated pre-op scans, the damping of pulsatile diametric distension was computed. Maximum localized diametric distension was 2.4±1.0%, 4.2±1.7%, and 5.5±1.6%, and axial deformation was 0.0±0.1%, −0.1±0.3%, and 1.1±0.6% in the endografts of TAA, TAD, and BTAI cohorts, respectively. Diametric distension damping from pre- to post-TEVAR was ~50%. Diametric and bending deformations were localized at certain axial positions on the endograft, and the inner curve bends more than the centerline, especially adjacent to overlapping regions. Conclusion: The presented techniques support investigation of multi-axial endograft deformations between disease causes and geometric locations on the device. Discretized quantification of deformation is needed to define device fatigue testing conditions and predict device durability in patients. Clinical Impact: This study demonstrates analytic techniques to quantify discretized deformation of thoracic endografts. Cardiac-resolved computed tomography is sometimes acquired for surgical planning and follow-up, however, the dynamic data are not typically used to quantify pulsatile deformations. Our analytic techniques extract the centerline and surface geometry of the stented thoracic aorta during the cardiac cycle, which are used to quantify diametric, axial, and bending deformations to provide better understanding of device durability and impact on the native anatomy.
- 24 July 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (3) , 653-659
Pulsatile Deformations of a Conformable Descending Thoracic Aortic Endograft in Aneurysm, Dissection, and Blunt Traumatic Aortic Injury Patients
Purpose: This study presents analytic techniques to quantify cardiac pulsatility-induced deformations of thoracic aortic endografts in patients with thoracic aortic aneurysm (TAA), dissection (TAD), and blunt thoracic aortic injury (BTAI) after thoracic endovascular aortic repair (TEVAR). Technique: We analyzed 19 image data sets from 14 patients treated for TAA, TAD, and BTAI with cardiac-gated post-TEVAR CTs. Systolic and diastolic geometric models were constructed and diametric, axial, and bending deformations were quantified. For patients with cardiac-gated pre-op scans, the damping of pulsatile diametric distension was computed. Maximum localized diametric distension was 2.4±1.0%, 4.2±1.7%, and 5.5±1.6%, and axial deformation was 0.0±0.1%, −0.1±0.3%, and 1.1±0.6% in the endografts of TAA, TAD, and BTAI cohorts, respectively. Diametric distension damping from pre- to post-TEVAR was ~50%. Diametric and bending deformations were localized at certain axial positions on the endograft, and the inner curve bends more than the centerline, especially adjacent to overlapping regions. Conclusion: The presented techniques support investigation of multi-axial endograft deformations between disease causes and geometric locations on the device. Discretized quantification of deformation is needed to define device fatigue testing conditions and predict device durability in patients. Clinical Impact: This study demonstrates analytic techniques to quantify discretized deformation of thoracic endografts. Cardiac-resolved computed tomography is sometimes acquired for surgical planning and follow-up, however, the dynamic data are not typically used to quantify pulsatile deformations. Our analytic techniques extract the centerline and surface geometry of the stented thoracic aorta during the cardiac cycle, which are used to quantify diametric, axial, and bending deformations to provide better understanding of device durability and impact on the native anatomy.
- 10 June 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (2) , 332-341
Cardiac Pulsatile Helical Deformation of the Thoracic Aorta Before and After Thoracic Endovascular Aortic Repair of Type B Dissections
Purpose: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. Material and Methods: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. Results: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. Conclusion: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. Clinical Impact: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.
- 10 June 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (2) , 332-341
Cardiac Pulsatile Helical Deformation of the Thoracic Aorta Before and After Thoracic Endovascular Aortic Repair of Type B Dissections
Purpose: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. Material and Methods: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. Results: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. Conclusion: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. Clinical Impact: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.
- 24 May 2023
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 78 (4) , 902-911
Renovisceral artery alterations due to branched endovascular aortic repair and respiratory-induced deformations
- 24 May 2023
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 78 (4) , 902-911
Renovisceral artery alterations due to branched endovascular aortic repair and respiratory-induced deformations