Johan Bondesson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johan Bondesson has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Christopher P. Cheng
Department of Surgery, Stanford University, Stanford, CA
9 shared publications - Ga-Young Suh
Department of Biomedical Engineering, California State University, Long Beach, CA, USA
6 shared publications Jason T. Lee
Division of Vascular Surgery, Stanford University, Stanford, CA, USA
5 shared publicationsMichael D. Dake
Department of Surgery, The University of Arizona, Tucson, AZ, USA
5 shared publicationsChristopher P. Cheng
Stanford University School of Medicine
3 shared publicationsGa-Young Suh
Department of Biomedical Engineering, California State University, Long Beach, Calif; Division of Vascular Surgery, Stanford University, Stanford, Calif
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 331 (4) , H1093-H1104
A cross-sectional analysis of vascular geometry in adults: associations of age and biological sex with iliofemoral arterial and venous tortuosity
Using an automated CT-based approach, this study quantified iliofemoral arterial and venous tortuosity in a large, adult cross-sectional cohort. Age had a strong positive association with arterial and venous tortuosity. Males had higher arterial and venous tortuosity than females. These findings support differential remodeling of arteries and veins with age and provide a framework for future studies of large-vessel geometry and mechanics.
- 1 October 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 331 (4) , H1093-H1104
Open AccessA cross-sectional analysis of vascular geometry in adults: associations of age and biological sex with iliofemoral arterial and venous tortuosity
Using an automated CT-based approach, this study quantified iliofemoral arterial and venous tortuosity in a large, adult cross-sectional cohort. Age had a strong positive association with arterial and venous tortuosity. Males had higher arterial and venous tortuosity than females. These findings support differential remodeling of arteries and veins with age and provide a framework for future studies of large-vessel geometry and mechanics.
- Open Access
- 23 June 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (5) , 102363
Aortic Remodeling after TEVAR and PETTICOAT to Treat Complicated Type B Aortic Dissection
- 23 June 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (5) , 102363
Open AccessAortic Remodeling after TEVAR and PETTICOAT to Treat Complicated Type B Aortic Dissection
- Open Access
- 23 January 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102522
Tibial Artery Stent Deformations From Ankle Plantarflexion and Dorsiflexion, Knee Flexion, and Simulated Calf Muscle Contraction
- 23 January 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102522
Open AccessTibial Artery Stent Deformations From Ankle Plantarflexion and Dorsiflexion, Knee Flexion, and Simulated Calf Muscle Contraction
- Open Access
- 15 September 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (6) , 101134
Impact of Stenting on PDA Length, Curvature, and Pulsatile Deformations Based on CT Assessment
- 15 September 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (6) , 101134
Open AccessImpact of Stenting on PDA Length, Curvature, and Pulsatile Deformations Based on CT Assessment
- 10 June 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (2) , 332-341
Cardiac Pulsatile Helical Deformation of the Thoracic Aorta Before and After Thoracic Endovascular Aortic Repair of Type B Dissections
Purpose: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. Material and Methods: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. Results: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. Conclusion: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. Clinical Impact: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.
- 10 June 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (2) , 332-341
Cardiac Pulsatile Helical Deformation of the Thoracic Aorta Before and After Thoracic Endovascular Aortic Repair of Type B Dissections
Purpose: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. Material and Methods: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. Results: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. Conclusion: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. Clinical Impact: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.
- 24 May 2023
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 78 (4) , 902-911
Renovisceral artery alterations due to branched endovascular aortic repair and respiratory-induced deformations
- 24 May 2023
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 78 (4) , 902-911
Renovisceral artery alterations due to branched endovascular aortic repair and respiratory-induced deformations
- 5 May 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (1) , 7-17
Ascending Aortic Endograft and Thoracic Aortic Deformation After Ascending Thoracic Endovascular Aortic Repair
Purpose: We aim to quantify multiaxial cardiac pulsatility-induced deformation of the thoracic aorta after ascending thoracic endovascular aortic repair (TEVAR) as a part of the GORE ARISE Early Feasibility Study. Materials and Methods: Fifteen patients (7 females and 8 males, age 73±9 years) with ascending TEVAR underwent computed tomography angiography with retrospective cardiac gating. Geometric modeling of the thoracic aorta was performed; geometric features including axial length, effective diameter, and centerline, inner surface, and outer surface curvatures were quantified for systole and diastole; and pulsatile deformations were calculated for the ascending aorta, arch, and descending aorta. Results: From diastole to systole, the ascending endograft exhibited straightening of the centerline (0.224±0.039 to 0.217±0.039 cm−1, p−1, p<0.05) curvatures. No significant changes were observed for inner surface curvature, diameter, or axial length in the ascending endograft. The aortic arch did not exhibit any significant deformation in axial length, diameter, or curvature. The descending aorta exhibited small but significant expansion of effective diameter from 2.59±0.46 to 2.63±0.44 cm (p<0.05). Conclusion: Compared with the native ascending aorta (from prior literature), ascending TEVAR damps axial and bending pulsatile deformations of the ascending aorta similar to how descending TEVAR damps descending aortic deformations, while diametric deformations are damped to a greater extent. Downstream diametric and bending pulsatility of the native descending aorta was muted compared with that in patients without ascending TEVAR (from prior literature). Deformation data from this study can be used to evaluate the mechanical durability of ascending aortic devices and inform physicians about the downstream effects of ascending TEVAR to help predict remodeling and guide future interventional strategies. Clinical Impact: This study quantified local deformations of both stented ascending and native descending aortas to reveal the biomechanical impact of ascending TEVAR on the entire thoracic aorta, and reported that the ascending TEVAR muted cardiac-induced deformation of the stented ascending aorta and native descending aorta. Understanding of in vivo deformations of the stented ascending aorta, aortic arch and descending aorta can inform physicians about the downstream effects of ascending TEVAR. Notable reduction of compliance may lead to cardiac remodeling and long-term systemic complications. This is the first report which included dedicated deformation data regarding ascending aortic endograft from clinical trial.
- 5 May 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (1) , 7-17
Ascending Aortic Endograft and Thoracic Aortic Deformation After Ascending Thoracic Endovascular Aortic Repair
Purpose: We aim to quantify multiaxial cardiac pulsatility-induced deformation of the thoracic aorta after ascending thoracic endovascular aortic repair (TEVAR) as a part of the GORE ARISE Early Feasibility Study. Materials and Methods: Fifteen patients (7 females and 8 males, age 73±9 years) with ascending TEVAR underwent computed tomography angiography with retrospective cardiac gating. Geometric modeling of the thoracic aorta was performed; geometric features including axial length, effective diameter, and centerline, inner surface, and outer surface curvatures were quantified for systole and diastole; and pulsatile deformations were calculated for the ascending aorta, arch, and descending aorta. Results: From diastole to systole, the ascending endograft exhibited straightening of the centerline (0.224±0.039 to 0.217±0.039 cm−1, p−1, p<0.05) curvatures. No significant changes were observed for inner surface curvature, diameter, or axial length in the ascending endograft. The aortic arch did not exhibit any significant deformation in axial length, diameter, or curvature. The descending aorta exhibited small but significant expansion of effective diameter from 2.59±0.46 to 2.63±0.44 cm (p<0.05). Conclusion: Compared with the native ascending aorta (from prior literature), ascending TEVAR damps axial and bending pulsatile deformations of the ascending aorta similar to how descending TEVAR damps descending aortic deformations, while diametric deformations are damped to a greater extent. Downstream diametric and bending pulsatility of the native descending aorta was muted compared with that in patients without ascending TEVAR (from prior literature). Deformation data from this study can be used to evaluate the mechanical durability of ascending aortic devices and inform physicians about the downstream effects of ascending TEVAR to help predict remodeling and guide future interventional strategies. Clinical Impact: This study quantified local deformations of both stented ascending and native descending aortas to reveal the biomechanical impact of ascending TEVAR on the entire thoracic aorta, and reported that the ascending TEVAR muted cardiac-induced deformation of the stented ascending aorta and native descending aorta. Understanding of in vivo deformations of the stented ascending aorta, aortic arch and descending aorta can inform physicians about the downstream effects of ascending TEVAR. Notable reduction of compliance may lead to cardiac remodeling and long-term systemic complications. This is the first report which included dedicated deformation data regarding ascending aortic endograft from clinical trial.
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 74 (5) , 1499-1507.e1
Influence of thoracic endovascular aortic repair on true lumen helical morphology for Stanford type B dissections
- 1 November 2021
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 74 (5) , 1499-1507.e1
Open AccessInfluence of thoracic endovascular aortic repair on true lumen helical morphology for Stanford type B dissections
- 1 February 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (2) , H901-H911
Quantification of true lumen helical morphology and chirality in type B aortic dissections
A novel definition of helical propagation of type B aortic dissections reveals a distinct bimodality, with the true lumen being either achiral (nonhelical) or exclusively right-handed. This right-handed chirality is consistent with anatomic and physiological phenomena such as right-handed twist during left ventricle contraction, helical blood flow, and tissue fiber direction. The helical character of aortic dissections may be useful for pathology research, diagnostics, treatment selection, therapeutic durability prediction, and aortic device design.
- 1 February 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (2) , H901-H911
Quantification of true lumen helical morphology and chirality in type B aortic dissections
A novel definition of helical propagation of type B aortic dissections reveals a distinct bimodality, with the true lumen being either achiral (nonhelical) or exclusively right-handed. This right-handed chirality is consistent with anatomic and physiological phenomena such as right-handed twist during left ventricle contraction, helical blood flow, and tissue fiber direction. The helical character of aortic dissections may be useful for pathology research, diagnostics, treatment selection, therapeutic durability prediction, and aortic device design.
- Open Access
- 1 January 2021
- Published by Elsevier in European Journal of Radiology Open
- Vol. 8, 100333
Multiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair
- 1 January 2021
- Published by Elsevier in European Journal of Radiology Open
- Vol. 8, 100333
Open AccessMultiaxial pulsatile dynamics of the thoracic aorta and impact of thoracic endovascular repair