M. Loubele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M. Loubele has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Frederik Maes
KU Leuven
3 shared publications P. Suetens
3 shared publications- Reinhilde Jacobs
OMFS-IMPATH Research Group, Department of Imaging and Pathology, Catholic University Leuven, Leuven, Belgium
3 shared publications D. van Steenberghe
2 shared publicationsD. Debaveye
1 shared publication- Dirk Vandermeulen
KU Leuven
1 shared publication
Latest Publications
- 1 April 2008
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 105 (4) , 512-518
Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
- 1 April 2008
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 105 (4) , 512-518
Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
- 18 February 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 129 (1-3) , 222-226
Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications
The image quality of four cone-beam computed tomography (CBCT) scanners dedicated for dentomaxillofacial imaging and one multi-slice computed tomgoraphy (MSCT) scanner was compared. For the MSCT scanner, a clinical and a low-dose protocol for oral indications were evaluated. The image quality was assessed by dedicated software that allows an automated analysis of accuracy measurements and evaluation of metal artefacts on two image quality phantoms. Bone was segmented with sub-millimetre accuracyin all scanners.
- 18 February 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 129 (1-3) , 222-226
Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications
The image quality of four cone-beam computed tomography (CBCT) scanners dedicated for dentomaxillofacial imaging and one multi-slice computed tomgoraphy (MSCT) scanner was compared. For the MSCT scanner, a clinical and a low-dose protocol for oral indications were evaluated. The image quality was assessed by dedicated software that allows an automated analysis of accuracy measurements and evaluation of metal artefacts on two image quality phantoms. Bone was segmented with sub-millimetre accuracyin all scanners.
- 1 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 117 (1-3) , 211-216
Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning
The goal of this study was to determine the acquisition parameters for a low-dose multi-slice CT protocol and to compare the effective dose and the image quality of this low-dose protocol with the image quality of a clinical multi-slice CT protocol, routinely used for visualisation of the head. The low-dose protocol was derived from a clinical multi-slice CT protocol by lowering mA s and kV and increasing the pitch. The low-dose protocol yielded a dose reduction from 1.5 to 0.18 mSv for a multi-slice CT scan of the whole head, whereas noise in the low-dose CT images was increased. For bone segmentation, noise could be reduced by use of a non-linear edge preserving smoothing filter. Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8.
- 1 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 117 (1-3) , 211-216
Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning
The goal of this study was to determine the acquisition parameters for a low-dose multi-slice CT protocol and to compare the effective dose and the image quality of this low-dose protocol with the image quality of a clinical multi-slice CT protocol, routinely used for visualisation of the head. The low-dose protocol was derived from a clinical multi-slice CT protocol by lowering mA s and kV and increasing the pitch. The low-dose protocol yielded a dose reduction from 1.5 to 0.18 mSv for a multi-slice CT scan of the whole head, whereas noise in the low-dose CT images was increased. For bone segmentation, noise could be reduced by use of a non-linear edge preserving smoothing filter. Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8.