Josef Hormes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Josef Hormes has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Hartwig Modrow
2 shared publicationsAlexander Prange
Institut für Mikrobiologie & Biotechnologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Meckenheimer Allee 168, D-53115, Bonn, Germany
1 shared publication- Arthur R. Woll
Cornell High Energy Synchrotron Source
1 shared publication - Christiane Dahl
Institut für Mikrobiologie & Biotechnologie, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
1 shared publication Claudia Engemann
Physikalisches Institut, Rheinische Friedrich-Wilhelms-Universität Bonn, Nußallee 12, D-53115 Bonn, Germany
1 shared publication- David N. Agyeman-Budu
Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA 94025, USA
1 shared publication
Latest Publications
- 24 August 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (35) , 8793-8802
In Situ Investigations of Laser-Generated Ligand-Free Platinum Nanoparticles by X-ray Absorption Spectroscopy: How Does the Immediate Environment Influence the Particle Surface?
Pulsed laser ablation in liquid (PLAL) has proven its usefulness as a nanoparticle (NP) synthesis method alternative to traditional chemical reduction methods, where the absence of any molecular ligands or residual reactants makes laser-generated nanoparticles ideal reference materials for charge transfer experiments. We synthesized additive-free platinum nanoparticles by PLAL and characterized in situ their interaction with H2O, a sodium phosphate buffer and sodium citrate as well as a TiO2 support by x-ray absorption fine structure (XAFS), i.e. x-ray absorption near-edge structure (XANES) and extended x-ray absorption fine structure (EXAFS). Differences in whiteline intensity between the colloidal particles in the three liquids indicate that the respective NP-solvent interaction varies in strength. The ions added ex situ diffuse through the particles’ electric double layer and interact electrostatically with the Stern plane. Consequently, these ions weaken the interaction of the functional OH-groups which are bound to the partially oxidized platinum surfaces and cause their partial reduction. Comparing XAFS spectra of laser-generated Pt NPs in citrate with wet-chemically synthesized ones (both ligand-covered) indicate different types of Pt-O-bonds: a Pt(IV)O2-type in case of wet-chemical and a Pt(II)O-type in case of laser-generated NPs. A comparison of unsupported laser-generated platinum NPs in H2O with TiO2-supported ones shows no whiteline intensity differences and also an identical number of Pt-O bonds in both cases. This suggests that in the deposition process at least part of the double layer coating stays intact and that the ligand-free particle properties are preserved.
- 24 August 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (35) , 8793-8802
In Situ Investigations of Laser-Generated Ligand-Free Platinum Nanoparticles by X-ray Absorption Spectroscopy: How Does the Immediate Environment Influence the Particle Surface?
Pulsed laser ablation in liquid (PLAL) has proven its usefulness as a nanoparticle (NP) synthesis method alternative to traditional chemical reduction methods, where the absence of any molecular ligands or residual reactants makes laser-generated nanoparticles ideal reference materials for charge transfer experiments. We synthesized additive-free platinum nanoparticles by PLAL and characterized in situ their interaction with H2O, a sodium phosphate buffer and sodium citrate as well as a TiO2 support by x-ray absorption fine structure (XAFS), i.e. x-ray absorption near-edge structure (XANES) and extended x-ray absorption fine structure (EXAFS). Differences in whiteline intensity between the colloidal particles in the three liquids indicate that the respective NP-solvent interaction varies in strength. The ions added ex situ diffuse through the particles’ electric double layer and interact electrostatically with the Stern plane. Consequently, these ions weaken the interaction of the functional OH-groups which are bound to the partially oxidized platinum surfaces and cause their partial reduction. Comparing XAFS spectra of laser-generated Pt NPs in citrate with wet-chemically synthesized ones (both ligand-covered) indicate different types of Pt-O-bonds: a Pt(IV)O2-type in case of wet-chemical and a Pt(II)O-type in case of laser-generated NPs. A comparison of unsupported laser-generated platinum NPs in H2O with TiO2-supported ones shows no whiteline intensity differences and also an identical number of Pt-O bonds in both cases. This suggests that in the deposition process at least part of the double layer coating stays intact and that the ligand-free particle properties are preserved.
- 21 January 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (3) , 759-766
Application of a spoked channel array to confocal X-ray fluorescence imaging and X-ray absorption spectroscopy of medieval stained glass
Confocal X-ray fluorescence imaging can determine the spatial distribution of elements in a depth-selective manner. The closely related technique of confocal X-ray absorption spectroscopy can reveal the chemical form of an element at a specific volume element in three dimensional space. Confocal measurement offers increased accuracy and avoids physical sectioning or ablative depth profiling methods, thus preserving sample integrity. At present, a polycapillary mounted on the detector is the common optical element used to complete the confocal configuration. Here we demonstrate implementation of a novel collection optic, a lithographically fabricated spoked channel array, to achieve the confocal configuration at beamline 20-ID, advanced photon source. The advantages of employing spoked channel arrays include improved spatial resolution and energy-independent probing volume. By employing this optic, three dimensional distributions of Fe, Ca and Mn and the localized chemical form of Fe were measured in the intact corrosion layer of an ancient stained glass sample obtained from 13th Century Paderborn Cathedral, Germany. Implementation of the optic enabled superior resolution depth selectivity in the intact corrosion layer and measurement of elemental distribution and speciation in a highly localized manner within the layer with improved signal to noise. The results show that both the composition and the chemical form vary as a function of three dimensional location in the corrosion layer. This observation is contrary to expectations from simple corrosion models assuming leaching processes and indicates that metal chemistry in these layers is quite complex.
- 21 January 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (3) , 759-766
Application of a spoked channel array to confocal X-ray fluorescence imaging and X-ray absorption spectroscopy of medieval stained glass
Confocal X-ray fluorescence imaging can determine the spatial distribution of elements in a depth-selective manner. The closely related technique of confocal X-ray absorption spectroscopy can reveal the chemical form of an element at a specific volume element in three dimensional space. Confocal measurement offers increased accuracy and avoids physical sectioning or ablative depth profiling methods, thus preserving sample integrity. At present, a polycapillary mounted on the detector is the common optical element used to complete the confocal configuration. Here we demonstrate implementation of a novel collection optic, a lithographically fabricated spoked channel array, to achieve the confocal configuration at beamline 20-ID, advanced photon source. The advantages of employing spoked channel arrays include improved spatial resolution and energy-independent probing volume. By employing this optic, three dimensional distributions of Fe, Ca and Mn and the localized chemical form of Fe were measured in the intact corrosion layer of an ancient stained glass sample obtained from 13th Century Paderborn Cathedral, Germany. Implementation of the optic enabled superior resolution depth selectivity in the intact corrosion layer and measurement of elemental distribution and speciation in a highly localized manner within the layer with improved signal to noise. The results show that both the composition and the chemical form vary as a function of three dimensional location in the corrosion layer. This observation is contrary to expectations from simple corrosion models assuming leaching processes and indicates that metal chemistry in these layers is quite complex.
- 10 September 2003
- Published by Wiley in Zeitschrift für anorganische und allgemeine Chemie
- Vol. 629 (10) , 1701-1708
In Situ Study of the Surface Oxidation of FeCr Alloys Using Grazing Incidence X‐ray Absorption Spectroscopy (GIXAS)
The surface oxidation of FeCr alloys with 18, 28, and 43 mass‐% Cr was investigated in situ using grazing‐incidence X‐ray absorption spectroscopy (GIXAS) at the chromium and iron K‐edges. Oxidation in air was monitored in situ in the temperature range from 290 K to 680 K. The standard GIXAS data analysis is extended for the treatment of a single layer model in order to estimate the chromium concentrations of the oxide layer and of the near‐interface substrate as well as the oxide layer thickness. XANES analysis shows transitions from b.c.c. Fe to corundum type Fe2O3 and from b.c.c. Cr to corundum type Cr2O3. The initial oxide layers are 1.1‐1.4 nm thick and contain 60‐90 mass‐% chromium, while the near‐interface substrate is depleted in Cr. During heating, iron oxide growth dominates up to 560‐600 K. Then the chromium oxide layer loses its passivation effect and Cr oxidation sets in.
- 10 September 2003
- Published by Wiley in Zeitschrift für anorganische und allgemeine Chemie
- Vol. 629 (10) , 1701-1708
In Situ Study of the Surface Oxidation of FeCr Alloys Using Grazing Incidence X‐ray Absorption Spectroscopy (GIXAS)
The surface oxidation of FeCr alloys with 18, 28, and 43 mass‐% Cr was investigated in situ using grazing‐incidence X‐ray absorption spectroscopy (GIXAS) at the chromium and iron K‐edges. Oxidation in air was monitored in situ in the temperature range from 290 K to 680 K. The standard GIXAS data analysis is extended for the treatment of a single layer model in order to estimate the chromium concentrations of the oxide layer and of the near‐interface substrate as well as the oxide layer thickness. XANES analysis shows transitions from b.c.c. Fe to corundum type Fe2O3 and from b.c.c. Cr to corundum type Cr2O3. The initial oxide layers are 1.1‐1.4 nm thick and contain 60‐90 mass‐% chromium, while the near‐interface substrate is depleted in Cr. During heating, iron oxide growth dominates up to 560‐600 K. Then the chromium oxide layer loses its passivation effect and Cr oxidation sets in.
- 4 August 1999
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - General Subjects
- Vol. 1428 (2-3) , 446-454
In situ analysis of sulfur in the sulfur globules of phototrophic sulfur bacteria by X-ray absorption near edge spectroscopy
- 4 August 1999
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - General Subjects
- Vol. 1428 (2-3) , 446-454
In situ analysis of sulfur in the sulfur globules of phototrophic sulfur bacteria by X-ray absorption near edge spectroscopy