Kerstin Lesny
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kerstin Lesny has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ayhan Gurbuz
Gazi Üniversitesi
1 shared publication - J. Wiemann1 shared publication
- Peter Hinz
PD Dr.-Ing., Institute of Soil Mechanics and Foundation Engineering, University of Duisburg-Essen, Universitaetsstrasse 15, 45117 Essen, Germany
1 shared publication - Samuel G. Paikowsky
Univ. of Massachusetts Lowell
1 shared publication
Latest Publications
- 18 May 2009
- Published by Taylor & Francis in Georisk: Assessment and Management of Risk for Engineered Systems and Geohazards
- Vol. 3 (2) , 97-105
Safety of shallow foundations – Limit State Design according to Eurocode 7 vs. alternative design concepts
The main objective of Eurocode 7 was to harmonise geotechnical design in Europe by consistently implementing limit state design. However, Eurocode 7 only provides a framework in which each member state defines the design approach as well as the partial factors according to national design and safety requirements. The design approaches differ in the way partial factors are applied and lead to remarkably different designs especially in the case of shallow foundations under complex loading. Hence, the actual safety of the foundation cannot be reliably determined. In the present paper the correlations between loads and resistances of shallow foundations within Eurocode 7 design are analysed by use of interaction diagrams. The effects of the design approaches on the overall safety are discussed. An alternative design method based on an unique failure criterion for the ultimate limit state is introduced, the implementation of the partial factor concept is discussed.
- 18 May 2009
- Published by Taylor & Francis in Georisk: Assessment and Management of Risk for Engineered Systems and Geohazards
- Vol. 3 (2) , 97-105
Safety of shallow foundations – Limit State Design according to Eurocode 7 vs. alternative design concepts
The main objective of Eurocode 7 was to harmonise geotechnical design in Europe by consistently implementing limit state design. However, Eurocode 7 only provides a framework in which each member state defines the design approach as well as the partial factors according to national design and safety requirements. The design approaches differ in the way partial factors are applied and lead to remarkably different designs especially in the case of shallow foundations under complex loading. Hence, the actual safety of the foundation cannot be reliably determined. In the present paper the correlations between loads and resistances of shallow foundations within Eurocode 7 design are analysed by use of interaction diagrams. The effects of the design approaches on the overall safety are discussed. An alternative design method based on an unique failure criterion for the ultimate limit state is introduced, the implementation of the partial factor concept is discussed.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 512-519
Design of Monopile Foundations for Offshore Wind Energy Converters
Offshore wind energy converters in water depth up to 20–25 m are mostly built on monopile foundations. Although it is a simple structure the monopile behaviour under transient loading from wind, waves and currents is very complex. Consequently, monopiles are often designed for the relevant extreme load event in a quasi-static approach. However, the effect of cyclic loading on the monopile behaviour has to be analysed as well, but no general accepted procedure currently exists. In the present paper the general design strategy is introduced and a method is suggested to analyse the monopile behaviour under cyclic loading. This method includes a combination of laboratory element tests and an appropriate design method.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 512-519
Design of Monopile Foundations for Offshore Wind Energy Converters
Offshore wind energy converters in water depth up to 20–25 m are mostly built on monopile foundations. Although it is a simple structure the monopile behaviour under transient loading from wind, waves and currents is very complex. Consequently, monopiles are often designed for the relevant extreme load event in a quasi-static approach. However, the effect of cyclic loading on the monopile behaviour has to be analysed as well, but no general accepted procedure currently exists. In the present paper the general design strategy is introduced and a method is suggested to analyse the monopile behaviour under cyclic loading. This method includes a combination of laboratory element tests and an appropriate design method.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 520-527
Offshore Wind Energy in Germany Compared to Other European Areas — Challenges and Recent Developments
Utilization of offshore wind energy in Europe is well in progress. A total capacity of about 1000 MW has already been installed. Eight wind farms with about 1300 MW are under construction and many more are planned. The existing wind farms are located relatively close to the shore in moderate water depths of up to 20 m. In contrast to this the site conditions in the planned wind farms in the German North and Baltic Sea are more demanding as these wind farms have to be built far off the shore. The present paper shows the current status of offshore wind energy in Europe and recent developments in Germany. Site conditions at various wind farm locations in the German North and Baltic Sea are illustrated and compared with the conditions in existing wind farms. Resulting consequences for foundation design and installation are discussed.
- 10 March 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 520-527
Offshore Wind Energy in Germany Compared to Other European Areas — Challenges and Recent Developments
Utilization of offshore wind energy in Europe is well in progress. A total capacity of about 1000 MW has already been installed. Eight wind farms with about 1300 MW are under construction and many more are planned. The existing wind farms are located relatively close to the shore in moderate water depths of up to 20 m. In contrast to this the site conditions in the planned wind farms in the German North and Baltic Sea are more demanding as these wind farms have to be built far off the shore. The present paper shows the current status of offshore wind energy in Europe and recent developments in Germany. Site conditions at various wind farm locations in the German North and Baltic Sea are illustrated and compared with the conditions in existing wind farms. Resulting consequences for foundation design and installation are discussed.
- 8 August 2008
- Published by Wiley in Bautechnik
- Vol. 85 (8) , 503-511
Gründung von Offshore‐Windenergieanlagen – Entscheidungshilfen für Entwurf und Bemessung
- 8 August 2008
- Published by Wiley in Bautechnik
- Vol. 85 (8) , 503-511
Gründung von Offshore‐Windenergieanlagen – Entscheidungshilfen für Entwurf und Bemessung
- 14 October 2007
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Scale Effects in Lateral Load Response of Large Diameter Monopiles
Monopile foundations are frequently used for offshore wind energy converters. These piles are highly laterally loaded structures with large horizontal forces and bending moments. Due to the harsh environmental conditions in the southern North Sea diameters of 4 to 8 m are required to maintain serviceability. In common practice smaller laterally loaded pipe piles are designed using the well-known p-y-method, in which the pile-soil stiffness is considered by nonlinear p-y-curves derived from field tests. An alternative design method is the strain wedge method in which the pile response is derived from the stress-strain relationship of the soil assuming a certain failure zone ahead of the pile. In the present paper, the design of a large diameter monopile foundation for typical loading conditions is presented. The pile response in cohesionless soil determined by the p-y method and the strain wedge method is compared with a finite element (FE) analysis with respect to scale effects when extrapolated from commonly used pipe pile diameters to large size monopiles.
- 14 October 2007
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Scale Effects in Lateral Load Response of Large Diameter Monopiles
Monopile foundations are frequently used for offshore wind energy converters. These piles are highly laterally loaded structures with large horizontal forces and bending moments. Due to the harsh environmental conditions in the southern North Sea diameters of 4 to 8 m are required to maintain serviceability. In common practice smaller laterally loaded pipe piles are designed using the well-known p-y-method, in which the pile-soil stiffness is considered by nonlinear p-y-curves derived from field tests. An alternative design method is the strain wedge method in which the pile response is derived from the stress-strain relationship of the soil assuming a certain failure zone ahead of the pile. In the present paper, the design of a large diameter monopile foundation for typical loading conditions is presented. The pile response in cohesionless soil determined by the p-y method and the strain wedge method is compared with a finite element (FE) analysis with respect to scale effects when extrapolated from commonly used pipe pile diameters to large size monopiles.
- 11 May 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 119-126
The Role of Favourable and Unfavourable Actions in the Design of Shallow Foundations according to Eurocode 7
For the design of shallow foundations under combined loading Eurocode 7 provides different partial safety factors for unfavourable and favourable actions and for different ultimate limit states. Several load combinations need to be checked to find the most critical combination of loading and limit state which governs design. Hence, the resulting safety is often not apparent. This paper illustrates the role of actions within the design of shallow foundations and points out the effects on the safety of the system.
- 11 May 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 119-126
The Role of Favourable and Unfavourable Actions in the Design of Shallow Foundations according to Eurocode 7
For the design of shallow foundations under combined loading Eurocode 7 provides different partial safety factors for unfavourable and favourable actions and for different ultimate limit states. Several load combinations need to be checked to find the most critical combination of loading and limit state which governs design. Hence, the resulting safety is often not apparent. This paper illustrates the role of actions within the design of shallow foundations and points out the effects on the safety of the system.
- 21 February 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-6
Finite-Element-Modelling of Large Diameter Monopiles for Offshore Wind Energy Converters
Monopiles for offshore wind energy converters are highly laterally loaded structures with diameters up to 6 m and more. Their design is based on the well-known p-y-method, which has been calibrated on field test results for much smaller pile diameters. The present paper provides an FE-analysis of the monopile behavior compared to the standard design method. The results indicate the influence of the pile diameter on the pile-soil stiffness and point out that the p-y-method overestimates the soil stiffness at great depth. A modification of the p-y-method is proposed which better accounts for the pile-soil interaction of large diameter monopiles.
- 21 February 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-6
Finite-Element-Modelling of Large Diameter Monopiles for Offshore Wind Energy Converters
Monopiles for offshore wind energy converters are highly laterally loaded structures with diameters up to 6 m and more. Their design is based on the well-known p-y-method, which has been calibrated on field test results for much smaller pile diameters. The present paper provides an FE-analysis of the monopile behavior compared to the standard design method. The results indicate the influence of the pile diameter on the pile-soil stiffness and point out that the p-y-method overestimates the soil stiffness at great depth. A modification of the p-y-method is proposed which better accounts for the pile-soil interaction of large diameter monopiles.