Suresh Narayanan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Suresh Narayanan has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Alec R. Sandy
X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, Illinois, USA
7 shared publications Deming Shu
Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publications- Eric M. Dufresne
Advanced Photon Source, Argonne National Laboratory, Lemont, USA
2 shared publications Jin Wang
Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439, USA
2 shared publicationsJoseph Sullivan
Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA
2 shared publications- Laurence Lurio
Department of Physics, Northern Illinois University, DeKalb, Illinois 60115, USA
2 shared publications
Latest Publications
- Open Access
- 28 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 490-498
Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion
An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.
- 28 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 490-498
Open AccessUse of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion
An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.
- Open Access
- 10 February 2016
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 23 (2) , 404-409
First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements
The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allowscontinuousacquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operatecontinuouslyin the microsecond time frame, while at the same time probing longer timescales.
- 10 February 2016
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 23 (2) , 404-409
Open AccessFirst experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements
The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allowscontinuousacquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operatecontinuouslyin the microsecond time frame, while at the same time probing longer timescales.
- 30 October 2013
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 46 (21) , 8628-8637
The Static and Dynamic Structure Factor of a Diblock Copolymer Melt via Small-Angle X-ray Scattering and X-ray Photon Correlation Spectroscopy
- 30 October 2013
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 46 (21) , 8628-8637
The Static and Dynamic Structure Factor of a Diblock Copolymer Melt via Small-Angle X-ray Scattering and X-ray Photon Correlation Spectroscopy
- Open Access
- 3 May 2011
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 106 (18) , 188301
Depletion-Induced Structure and Dynamics in Bimodal Colloidal Suspensions
Combined small angle x-ray scattering and x-ray photon correlation spectroscopy studies of moderately concentrated bimodal hard-sphere colloidal suspensions in the fluid phase show that depletion-induced demixing introduces spatially heterogeneous dynamics with two distinct time scales. The adhesive nature, as well as the mobility, of the large particles is determined by the level of interaction within the monomodal domains. This interaction is driven by osmotic forces, which are governed by the relative concentration of the constituents.
- 3 May 2011
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 106 (18) , 188301
Open AccessDepletion-Induced Structure and Dynamics in Bimodal Colloidal Suspensions
Combined small angle x-ray scattering and x-ray photon correlation spectroscopy studies of moderately concentrated bimodal hard-sphere colloidal suspensions in the fluid phase show that depletion-induced demixing introduces spatially heterogeneous dynamics with two distinct time scales. The adhesive nature, as well as the mobility, of the large particles is determined by the level of interaction within the monomodal domains. This interaction is driven by osmotic forces, which are governed by the relative concentration of the constituents.
- 18 December 2007
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 15 (1) , 12-18
Design and performance of an ultra-high-vacuum-compatible artificial channel-cut monochromator
The design and performance of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been commissioned at undulator beamline 8-ID-I at the Advanced Photon Source are presented. Details of the mechanical and optical design, control system implementation and performance of the new device are given. The monochromator was designed to meet the challenging stability and optical requirements of the X-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine-tuning the pitch and roll of the second crystal relative to the first crystal. The monochromator delivers an exceptionally uniform and stable beam and thereby improved brilliance preservation.
- 18 December 2007
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 15 (1) , 12-18
Design and performance of an ultra-high-vacuum-compatible artificial channel-cut monochromator
The design and performance of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been commissioned at undulator beamline 8-ID-I at the Advanced Photon Source are presented. Details of the mechanical and optical design, control system implementation and performance of the new device are given. The monochromator was designed to meet the challenging stability and optical requirements of the X-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine-tuning the pitch and roll of the second crystal relative to the first crystal. The monochromator delivers an exceptionally uniform and stable beam and thereby improved brilliance preservation.
- 4 May 2007
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 98 (18) , 185506
Particle Dynamics in Polymer-Metal Nanocomposite Thin Films on Nanometer-Length Scales
X-ray photon correlation spectroscopy was used in conjunction with resonance-enhanced grazing-incidence small-angle x-ray scattering to probe slow particle dynamics and kinetics in gold/polystyrene nanocomposite thin films. Such enhanced coherent scattering enables, for the first time, measurement of the particle dynamics at wave vectors up to (or a few nanometers spatially) in a disordered system, well in the regime where entanglement, confinement, and particle interaction dominate the dynamics and kinetics. Measurements of the intermediate structure factor indicate that the particle dynamics differ from Stokes-Einstein Brownian motion and are explained in terms of viscoelastic effects and interparticle interactions.- 4 May 2007
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 98 (18) , 185506
Particle Dynamics in Polymer-Metal Nanocomposite Thin Films on Nanometer-Length Scales
X-ray photon correlation spectroscopy was used in conjunction with resonance-enhanced grazing-incidence small-angle x-ray scattering to probe slow particle dynamics and kinetics in gold/polystyrene nanocomposite thin films. Such enhanced coherent scattering enables, for the first time, measurement of the particle dynamics at wave vectors up to (or a few nanometers spatially) in a disordered system, well in the regime where entanglement, confinement, and particle interaction dominate the dynamics and kinetics. Measurements of the intermediate structure factor indicate that the particle dynamics differ from Stokes-Einstein Brownian motion and are explained in terms of viscoelastic effects and interparticle interactions.- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1027
Nanoparticle suspensions studied by x-ray photon correlation spectroscopy
Multispeckle x-ray photon correlation spectroscopy measurements, carried out at beamline 8-ID at the Advanced Photon Source at Argonne National Laboratory, of opaque suspensions of silica nanoparticles in water and lutidine-water binary mixtures are presented.
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1027
Nanoparticle suspensions studied by x-ray photon correlation spectroscopy
Multispeckle x-ray photon correlation spectroscopy measurements, carried out at beamline 8-ID at the Advanced Photon Source at Argonne National Laboratory, of opaque suspensions of silica nanoparticles in water and lutidine-water binary mixtures are presented.
- 15 December 2006
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 14 (1) , 138-143
A sagittally focusing double-multilayer monochromator for ultrafast X-ray imaging applications
The development of a sagittally focusing double-multilayer monochromator is reported, which produces a spatially extended wide-bandpass X-ray beam from an intense synchrotron bending-magnet source at the Advanced Photon Source, for ultrafast X-ray radiography and tomography applications. This monochromator consists of two W/B(4)C multilayers with a 25 A period coated on Si single-crystal substrates. The second multilayer is mounted on a sagittally focusing bender, which can dynamically change the bending radius of the multilayer in order to condense and focus the beam to various points along the beamline. With this new apparatus, it becomes possible to adjust the X-ray beam size to best match the area detector size and the object size to facilitate more efficient data collection using ultrafast X-ray radiography and tomography.
- 15 December 2006
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 14 (1) , 138-143
A sagittally focusing double-multilayer monochromator for ultrafast X-ray imaging applications
The development of a sagittally focusing double-multilayer monochromator is reported, which produces a spatially extended wide-bandpass X-ray beam from an intense synchrotron bending-magnet source at the Advanced Photon Source, for ultrafast X-ray radiography and tomography applications. This monochromator consists of two W/B(4)C multilayers with a 25 A period coated on Si single-crystal substrates. The second multilayer is mounted on a sagittally focusing bender, which can dynamically change the bending radius of the multilayer in order to condense and focus the beam to various points along the beamline. With this new apparatus, it becomes possible to adjust the X-ray beam size to best match the area detector size and the object size to facilitate more efficient data collection using ultrafast X-ray radiography and tomography.
- 31 August 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6317, 63171D-63171
Design and characterization of an UHV compatible artificial channel cut monochromator
We present design and characterization results of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been installed at the undulator beamline 8-ID-I at the Advanced Photon Source. The monochromator has been designed to meet the challenging stability and optical requirements of the x-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine tuning the pitch and roll of the second crystal relative to the first crystal.
- 31 August 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6317, 63171D-63171
Design and characterization of an UHV compatible artificial channel cut monochromator
We present design and characterization results of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been installed at the undulator beamline 8-ID-I at the Advanced Photon Source. The monochromator has been designed to meet the challenging stability and optical requirements of the x-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine tuning the pitch and roll of the second crystal relative to the first crystal.
- 19 July 2006
- Published by American Physical Society (APS) in Physical Review E
- Vol. 74 (1) , 010602
Observation of a low-viscosity interface between immiscible polymer layers
X-ray photon correlation spectroscopy was employed in a surface standing wave geometry in order to resolve the thermally driven in-plane dynamics at both the surface/vacuum (top) and polymer/polymer (bottom) interfaces of a thin polystyrene (PS) film on top of Poly(4-bromo styrene) and supported on a Si substrate. The top vacuum interface shows two relaxation modes: one fast and one slow, while the buried polymer-polymer interface shows a single slow mode. The slow mode of the top interface is similar in magnitude and wave vector dependence to the single mode of the buried interface. The dynamics are consistent with a low-viscosity mixed layer between the PS and and coupling of the capillary wave fluctuations between this layer and the PS.- 19 July 2006
- Published by American Physical Society (APS) in Physical Review E
- Vol. 74 (1) , 010602
Observation of a low-viscosity interface between immiscible polymer layers
X-ray photon correlation spectroscopy was employed in a surface standing wave geometry in order to resolve the thermally driven in-plane dynamics at both the surface/vacuum (top) and polymer/polymer (bottom) interfaces of a thin polystyrene (PS) film on top of Poly(4-bromo styrene) and supported on a Si substrate. The top vacuum interface shows two relaxation modes: one fast and one slow, while the buried polymer-polymer interface shows a single slow mode. The slow mode of the top interface is similar in magnitude and wave vector dependence to the single mode of the buried interface. The dynamics are consistent with a low-viscosity mixed layer between the PS and and coupling of the capillary wave fluctuations between this layer and the PS.