Laurence Lurio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Laurence Lurio has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Alec R. Sandy
X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, Illinois, USA
4 shared publications Jyotsana Lal
Department of Physics, Northern Illinois University, DeKalb, IL 60115-2828, USA
3 shared publicationsSuresh Narayanan
X-Ray Science Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
3 shared publications- Elizabeth R. Gaillard
Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb, IL
2 shared publications Evguenia A. Karapetrova
33BM Sector Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439-4832, USA
2 shared publications- Suresh Narayanan
Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439, USA
2 shared publications
Latest Publications
- 17 June 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (28) , 5785-5792
X-ray fluorescence standing wave study of the interaction of the antimicrobial peptide indolicidin with a supported model membrane
Indolicidin, a cationic antimicrobial peptide, interacts with lipid bilayers through electrostatic and hydrophobic interactions, disrupting microbial membranes. We investigated the depth-dependent localization of gold-nanoparticle-labeled indolicidin in a supported model membrane using X-ray fluorescence standing wave (SWXF) analysis. Liposomes composed of DMPC and DMPG were incubated with indolicidin labeled at its C-terminus with a 1.8 nm gold nanoparticle, then deposited onto a Si/Mo multilayer substrate via vesicle bursting. SWXF measurements revealed that at low peptide incubation concentrations (2–5 μM), gold-nanoparticle-labeled indolicidin remains primarily associated with the bilayer's outer leaflet. At higher concentrations (10 μM), the peptide penetrates deeper into the bilayer, with the labeled C-terminal region either localizing near the membrane's hydrophobic core or inducing membrane breakup. These findings suggest a concentration-dependent insertion mechanism.
- 17 June 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (28) , 5785-5792
X-ray fluorescence standing wave study of the interaction of the antimicrobial peptide indolicidin with a supported model membrane
Indolicidin, a cationic antimicrobial peptide, interacts with lipid bilayers through electrostatic and hydrophobic interactions, disrupting microbial membranes. We investigated the depth-dependent localization of gold-nanoparticle-labeled indolicidin in a supported model membrane using X-ray fluorescence standing wave (SWXF) analysis. Liposomes composed of DMPC and DMPG were incubated with indolicidin labeled at its C-terminus with a 1.8 nm gold nanoparticle, then deposited onto a Si/Mo multilayer substrate via vesicle bursting. SWXF measurements revealed that at low peptide incubation concentrations (2–5 μM), gold-nanoparticle-labeled indolicidin remains primarily associated with the bilayer's outer leaflet. At higher concentrations (10 μM), the peptide penetrates deeper into the bilayer, with the labeled C-terminal region either localizing near the membrane's hydrophobic core or inducing membrane breakup. These findings suggest a concentration-dependent insertion mechanism.
- Open Access
- 20 April 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 677-686
High-throughput nuclear resonance time domain interferometry using annular slits
Nuclear resonance time domain interferometry (NR-TDI) is used to study the slow dynamics of liquids (that do not require Mössbauer isotopes) at atomic and molecular length scales. Here the TDI method of using a stationary two-line magnetized 57Fe foil as a source and a stationary single-line stainless steel foil analyzer is employed. The new technique of adding an annular slit in front of a single silicon avalanche photodiode detector enables a wide range of momentum transfers (1 to 100 nm−1 by varying the distance between the annular slits and sample) with a high count rate of up to 160 Hz with a Δq resolution of ±1.7 nm−1 at q = 14 nm−1. The sensitivity of this method in determining relaxation times is quantified and discussed. The Kohlrausch–Williams–Watts (KWW) model was used to extract relaxation times for glycerol. These relaxation times give insight into the dynamics of the electron density fluctuations of glycerol as a function of temperature and momentum transfers.
- 20 April 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 677-686
Open AccessHigh-throughput nuclear resonance time domain interferometry using annular slits
Nuclear resonance time domain interferometry (NR-TDI) is used to study the slow dynamics of liquids (that do not require Mössbauer isotopes) at atomic and molecular length scales. Here the TDI method of using a stationary two-line magnetized 57Fe foil as a source and a stationary single-line stainless steel foil analyzer is employed. The new technique of adding an annular slit in front of a single silicon avalanche photodiode detector enables a wide range of momentum transfers (1 to 100 nm−1 by varying the distance between the annular slits and sample) with a high count rate of up to 160 Hz with a Δq resolution of ±1.7 nm−1 at q = 14 nm−1. The sensitivity of this method in determining relaxation times is quantified and discussed. The Kohlrausch–Williams–Watts (KWW) model was used to extract relaxation times for glycerol. These relaxation times give insight into the dynamics of the electron density fluctuations of glycerol as a function of temperature and momentum transfers.
- Open Access
- 28 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 490-498
Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion
An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.
- 28 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 490-498
Open AccessUse of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion
An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.
- 10 September 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (3) , 032802
Universal dynamics of coarsening during polymer-polymer thin-film spinodal dewetting kinetics
The dewetting dynamics of a supported bilayer polymer thin film on a solid substrate is investigated using grazing incidence x-ray photon correlation spectroscopy. We find that the top layer dewets via the spinodal mechanism. The kinetics of the dewetting is studied by monitoring the time evolution of the surface diffuse x-ray scattering intensity. We study the time evolution of fluctuations about the average surface structure by measuring the two-time x-ray intensity fluctuation correlation functions. Using these two-time correlation functions we quantify the crossover from early-time diffusive dynamics to hydrodynamics. The early diffusive regime satisfies dynamic universality. The two-time correlation functions also quantify the onset of hydrodynamic effects. The hydrodynamic regime is observed during the spinodal dewetting process as these interactions are not screened.
- 10 September 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (3) , 032802
Universal dynamics of coarsening during polymer-polymer thin-film spinodal dewetting kinetics
The dewetting dynamics of a supported bilayer polymer thin film on a solid substrate is investigated using grazing incidence x-ray photon correlation spectroscopy. We find that the top layer dewets via the spinodal mechanism. The kinetics of the dewetting is studied by monitoring the time evolution of the surface diffuse x-ray scattering intensity. We study the time evolution of fluctuations about the average surface structure by measuring the two-time x-ray intensity fluctuation correlation functions. Using these two-time correlation functions we quantify the crossover from early-time diffusive dynamics to hydrodynamics. The early diffusive regime satisfies dynamic universality. The two-time correlation functions also quantify the onset of hydrodynamic effects. The hydrodynamic regime is observed during the spinodal dewetting process as these interactions are not screened.
- 6 August 2020
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 22 (34) , 19089-19099
Structure of supported DPPC/cholesterol bilayers studied via X-ray reflectivity
The electron density profile of bilayers of DPPC/cholesterol mixtures supported on semiconductor grade silicon substrates were studied with the objective of determining how the proximity of a solid interface modifies the phase diagram of mixed bilayers. The bilayers were studied in situ immersed in water via synchrotron X-ray reflectivity (XRR). Measurements were performed as a function of temperature through the main phase transition and cholesterol mole fractions up to 40%. Analysis of XRR yields the bilayer thickness, roughness and leaflet asymmetry. We find that the structure of the pure DPPC bilayers in the gel phase is in agreement with previous X-ray measurements of supported bilayers deposited via vesicle fusion and multilamellar vesicles but show more clearly defined features than measurements made on films formed using Langmuir–Blodget Langmuir–Shaffer (LB) deposition. Examination of bilayer thickness vs. temperature shows that the melting temperature for supported bilayers is shifted upwards by approximately 4 °C relative to multilamellar vesicles and that the melting temperature decreases with increasing cholesterol content up to 20%. For pure DPPC bilayers the leaflets melt in two stages with the distal leaflet melting first. For cholesterol concentrations of 10% and 20% there is no clear indication of separate melting. For 33% and 40% cholesterol content no clear transition is seen in the bilayer thickness, but an abrupt change in roughness indicates possible microdomain formation in the 40% cholesterol sample.
- 6 August 2020
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 22 (34) , 19089-19099
Structure of supported DPPC/cholesterol bilayers studied via X-ray reflectivity
The electron density profile of bilayers of DPPC/cholesterol mixtures supported on semiconductor grade silicon substrates were studied with the objective of determining how the proximity of a solid interface modifies the phase diagram of mixed bilayers. The bilayers were studied in situ immersed in water via synchrotron X-ray reflectivity (XRR). Measurements were performed as a function of temperature through the main phase transition and cholesterol mole fractions up to 40%. Analysis of XRR yields the bilayer thickness, roughness and leaflet asymmetry. We find that the structure of the pure DPPC bilayers in the gel phase is in agreement with previous X-ray measurements of supported bilayers deposited via vesicle fusion and multilamellar vesicles but show more clearly defined features than measurements made on films formed using Langmuir–Blodget Langmuir–Shaffer (LB) deposition. Examination of bilayer thickness vs. temperature shows that the melting temperature for supported bilayers is shifted upwards by approximately 4 °C relative to multilamellar vesicles and that the melting temperature decreases with increasing cholesterol content up to 20%. For pure DPPC bilayers the leaflets melt in two stages with the distal leaflet melting first. For cholesterol concentrations of 10% and 20% there is no clear indication of separate melting. For 33% and 40% cholesterol content no clear transition is seen in the bilayer thickness, but an abrupt change in roughness indicates possible microdomain formation in the 40% cholesterol sample.
- Open Access
- 2 February 2018
- Published by American Physical Society (APS) in Physical Review E
- Vol. 97 (2) , 020601
Hard-sphere-like dynamics in highly concentrated alpha-crystallin suspensions
The dynamics of concentrated suspensions of the eye-lens protein alpha crystallin have been measured using x-ray photon correlation spectroscopy. Measurements were made at wave vectors corresponding to the first peak in the hard-sphere structure factor and volume fractions close to the critical volume fraction for the glass transition. Langevin dynamics simulations were also performed in parallel to the experiments. The intermediate scattering function could be fit using a stretched exponential decay for both experiments and numerical simulations. The measured relaxation times show good agreement with simulations for polydisperse hard-sphere colloids.- 2 February 2018
- Published by American Physical Society (APS) in Physical Review E
- Vol. 97 (2) , 020601
Open AccessHard-sphere-like dynamics in highly concentrated alpha-crystallin suspensions
The dynamics of concentrated suspensions of the eye-lens protein alpha crystallin have been measured using x-ray photon correlation spectroscopy. Measurements were made at wave vectors corresponding to the first peak in the hard-sphere structure factor and volume fractions close to the critical volume fraction for the glass transition. Langevin dynamics simulations were also performed in parallel to the experiments. The intermediate scattering function could be fit using a stretched exponential decay for both experiments and numerical simulations. The measured relaxation times show good agreement with simulations for polydisperse hard-sphere colloids. - 26 August 2013
- Published by American Physical Society (APS) in Physical Review B
- Vol. 88 (5) , 054512
Pressure-dependent phase transformation of solid helium confined within a nanoporous material
Transmission x-ray diffraction experiments have been carried out on solid helium grown in porous Vycor glass. Measurements were made at temperatures near 0.7 K and at pressures up to 162 bars. The crystalline phases of solid helium in Vycor are found to differ significantly from the bulk. At pressures from 70 bars through 98 bars the helium is polycrystalline and displays a single size broadened scattering peak. Above 98 bars the peak splits into three close peaks. No higher order peaks are seen at any pressure, indicating significant reduction in intensity due to disorder. A broad peak is present at all pressures, which may indicate the presence of amorphous solid. We tentatively identify the low-pressure phase as bcc and the high-pressure phase as coexistence between bcc and hcp. Size broadening indicates an average grain size of approximately 5 nm, comparable to the Vycor pore size.
- 26 August 2013
- Published by American Physical Society (APS) in Physical Review B
- Vol. 88 (5) , 054512
Pressure-dependent phase transformation of solid helium confined within a nanoporous material
Transmission x-ray diffraction experiments have been carried out on solid helium grown in porous Vycor glass. Measurements were made at temperatures near 0.7 K and at pressures up to 162 bars. The crystalline phases of solid helium in Vycor are found to differ significantly from the bulk. At pressures from 70 bars through 98 bars the helium is polycrystalline and displays a single size broadened scattering peak. Above 98 bars the peak splits into three close peaks. No higher order peaks are seen at any pressure, indicating significant reduction in intensity due to disorder. A broad peak is present at all pressures, which may indicate the presence of amorphous solid. We tentatively identify the low-pressure phase as bcc and the high-pressure phase as coexistence between bcc and hcp. Size broadening indicates an average grain size of approximately 5 nm, comparable to the Vycor pore size.
- 1 February 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 20 (2) , 332-338
X-ray speckle visibility spectroscopy in the single-photon limit
The technique of speckle visibility spectroscopy has been employed for the measurement of dynamics using coherent X-ray scattering. It is shown that the X-ray contrast within a single exposure can be related to the relaxation time of the intermediate scattering function, and this methodology is applied to the diffusion of 72 nm-radius latex spheres in glycerol. Data were collected with exposure times as short as 2 ms by employing a resonant shutter. The weak scattering present for short exposures necessitated an analysis formalism based on the spatial correlation function of individual photon charge droplets on an area detector, rather than the usual methods employed for intensity correlations. It is demonstrated that this method gives good agreement between theory and experiment and thus holds promise for extending area-detector-based coherent scattering methods to the study of faster dynamics than previously obtainable.
- 1 February 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 20 (2) , 332-338
X-ray speckle visibility spectroscopy in the single-photon limit
The technique of speckle visibility spectroscopy has been employed for the measurement of dynamics using coherent X-ray scattering. It is shown that the X-ray contrast within a single exposure can be related to the relaxation time of the intermediate scattering function, and this methodology is applied to the diffusion of 72 nm-radius latex spheres in glycerol. Data were collected with exposure times as short as 2 ms by employing a resonant shutter. The weak scattering present for short exposures necessitated an analysis formalism based on the spatial correlation function of individual photon charge droplets on an area detector, rather than the usual methods employed for intensity correlations. It is demonstrated that this method gives good agreement between theory and experiment and thus holds promise for extending area-detector-based coherent scattering methods to the study of faster dynamics than previously obtainable.
- 16 October 2007
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 14 (6) , 527-531
Windows for small-angle X-ray scattering cryostats
To determine the suitability of commonly used windows for small-angle X-ray scattering, a range of materials, including Kapton, (aluminized) Mylar, beryllium, high-purity aluminium foil, mica and silicon nitride have been studied. At small wavevector transfers, Q, in the range 2 x 10(-3) to 0.2 nm(-1), the scattering from Kapton, mica and beryllium is reasonably well described by power laws in Q with exponents of -3.25, -3.6 and -3.9, respectively. There are large variations in the scattering from mica, but a freshly cleaved natural mica window was by far the weakest scatterer. For applications where radiation in the infrared or visible range should be blocked, aluminized Mylar is the most suitable material. Both Mylar and Kapton can be used to make very simple demountable superfluid-tight windows using indium O-ring seals.
- 16 October 2007
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 14 (6) , 527-531
Windows for small-angle X-ray scattering cryostats
To determine the suitability of commonly used windows for small-angle X-ray scattering, a range of materials, including Kapton, (aluminized) Mylar, beryllium, high-purity aluminium foil, mica and silicon nitride have been studied. At small wavevector transfers, Q, in the range 2 x 10(-3) to 0.2 nm(-1), the scattering from Kapton, mica and beryllium is reasonably well described by power laws in Q with exponents of -3.25, -3.6 and -3.9, respectively. There are large variations in the scattering from mica, but a freshly cleaved natural mica window was by far the weakest scatterer. For applications where radiation in the infrared or visible range should be blocked, aluminized Mylar is the most suitable material. Both Mylar and Kapton can be used to make very simple demountable superfluid-tight windows using indium O-ring seals.
- 19 July 2006
- Published by American Physical Society (APS) in Physical Review E
- Vol. 74 (1) , 010602
Observation of a low-viscosity interface between immiscible polymer layers
X-ray photon correlation spectroscopy was employed in a surface standing wave geometry in order to resolve the thermally driven in-plane dynamics at both the surface/vacuum (top) and polymer/polymer (bottom) interfaces of a thin polystyrene (PS) film on top of Poly(4-bromo styrene) and supported on a Si substrate. The top vacuum interface shows two relaxation modes: one fast and one slow, while the buried polymer-polymer interface shows a single slow mode. The slow mode of the top interface is similar in magnitude and wave vector dependence to the single mode of the buried interface. The dynamics are consistent with a low-viscosity mixed layer between the PS and and coupling of the capillary wave fluctuations between this layer and the PS.- 19 July 2006
- Published by American Physical Society (APS) in Physical Review E
- Vol. 74 (1) , 010602
Observation of a low-viscosity interface between immiscible polymer layers
X-ray photon correlation spectroscopy was employed in a surface standing wave geometry in order to resolve the thermally driven in-plane dynamics at both the surface/vacuum (top) and polymer/polymer (bottom) interfaces of a thin polystyrene (PS) film on top of Poly(4-bromo styrene) and supported on a Si substrate. The top vacuum interface shows two relaxation modes: one fast and one slow, while the buried polymer-polymer interface shows a single slow mode. The slow mode of the top interface is similar in magnitude and wave vector dependence to the single mode of the buried interface. The dynamics are consistent with a low-viscosity mixed layer between the PS and and coupling of the capillary wave fluctuations between this layer and the PS.