Catherine Champmartin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Catherine Champmartin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Lisa Chedik
Institut national de recherche et de sécurité pour la prévention des accidents du travail et des maladies professionnelles (INRS), Dept Toxicologie et Biométrologie, 1 rue du Morvan, 54519 Vandoeuvre-lès-Nancy, France
4 shared publications - Frédéric Cosnier
Institut National de Recherche et de Sécurité, Rue du Morvan, CS 60027, F-54519 Vandœuvre Cedex, France
3 shared publications - Fabrice Marquet
Institut National de Recherche et de Sécurité, rue du Morvan, CS 60027, 54519 Vandoeuvre les Nancy, Cedex, France
2 shared publications - Matthieu Aubertin
French Research and Safety Institute for the Prevention of Occupational Accidents and Diseases (INRS), Toxicology and Biomonitoring Division, 1 rue Morvan, F-54519 Vandoeuvre les Nancy, France
2 shared publications - Anja Franken
Occupational Hygiene and Health Research Initiative, North-West University, Potchefstroom, South Africa
1 shared publication - Anneli Julander
IVL Swedish Environmental Research Institute
1 shared publication
Latest Publications
- Open Access
- 18 October 2024
- Published by Elsevier in Chemosphere
- Vol. 367, 143564
Percutaneous absorption of two bisphenol a analogues, BPAF and TGSA: Novel In vitro data from human skin
- 18 October 2024
- Published by Elsevier in Chemosphere
- Vol. 367, 143564
Open AccessPercutaneous absorption of two bisphenol a analogues, BPAF and TGSA: Novel In vitro data from human skin
- Open Access
- 21 April 2022
- Published by Taylor & Francis in Critical Reviews in Toxicology
- Vol. 52 (4) , 294-316
Occupational exposure assessment with solid substances: choosing a vehicle for in vitro percutaneous absorption experiments
Percutaneous occupational exposure to industrial toxicants can be assessed in vitro on excised human or animal skins. Numerous factors can significantly influence skin permeation of chemicals and the flux determination. Among them, the vehicle used to solubilize the solid substances is a tricky key step. A “realistic surrogate” that closely matches the exposure scenario is recommended in first intention. When direct transposition of occupational exposure conditions to in vitro experiments is impossible, it is recommended that the vehicle used does not affect the skin barrier (in particular in terms of structural integrity, composition, or enzymatic activity). Indeed, any such effect could alter the percutaneous absorption of substances in a number of ways, as we will see. Potential effects are described for five monophasic vehicles, including the three most frequently used: water, ethanol, acetone; and two that are more rarely used, but are realistic: artificial sebum and artificial sweat. Finally, we discuss a number of criteria to be verified and the associated tests that should be performed when choosing the most appropriate vehicle, keeping in mind that, in the context of occupational exposure, the scientific quality of the percutaneous absorption data provided, and how they are interpreted, may have long-range consequences. From the narrative review presented, we also identify and discuss important factors to consider in future updates of the OECD guidelines for in vitro skin absorption experiments.
- 21 April 2022
- Published by Taylor & Francis in Critical Reviews in Toxicology
- Vol. 52 (4) , 294-316
Open AccessOccupational exposure assessment with solid substances: choosing a vehicle for in vitro percutaneous absorption experiments
Percutaneous occupational exposure to industrial toxicants can be assessed in vitro on excised human or animal skins. Numerous factors can significantly influence skin permeation of chemicals and the flux determination. Among them, the vehicle used to solubilize the solid substances is a tricky key step. A “realistic surrogate” that closely matches the exposure scenario is recommended in first intention. When direct transposition of occupational exposure conditions to in vitro experiments is impossible, it is recommended that the vehicle used does not affect the skin barrier (in particular in terms of structural integrity, composition, or enzymatic activity). Indeed, any such effect could alter the percutaneous absorption of substances in a number of ways, as we will see. Potential effects are described for five monophasic vehicles, including the three most frequently used: water, ethanol, acetone; and two that are more rarely used, but are realistic: artificial sebum and artificial sweat. Finally, we discuss a number of criteria to be verified and the associated tests that should be performed when choosing the most appropriate vehicle, keeping in mind that, in the context of occupational exposure, the scientific quality of the percutaneous absorption data provided, and how they are interpreted, may have long-range consequences. From the narrative review presented, we also identify and discuss important factors to consider in future updates of the OECD guidelines for in vitro skin absorption experiments.
- 1 November 2020
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 117, 104752
Reflections on the OECD guidelines for in vitro skin absorption studies
- 1 November 2020
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 117, 104752
Reflections on the OECD guidelines for in vitro skin absorption studies
- 1 August 2020
- Published by Elsevier in Chemosphere
- Vol. 252, 126525
Human in vitro percutaneous absorption of bisphenol S and bisphenol A: A comparative study
- 1 August 2020
- Published by Elsevier in Chemosphere
- Vol. 252, 126525
Human in vitro percutaneous absorption of bisphenol S and bisphenol A: A comparative study
- Open Access
- 9 January 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (3) , 321-332
Maintenance of Low-Pressure Carburising Furnaces: A Source of PAH Exposure
Low-pressure carburising is a new technology used to harden steel; the process has been shown to be a source of considerable polycyclic aromatic hydrocarbons (PAH) pollution. Some PAH are carcinogenic, and activities such as furnace maintenance may thus represent a risk to workers. Occupational exposure during these operations should therefore be assessed. In this study, the PAH-related carcinogenic risk associated with furnace maintenance was assessed by monitoring atmospheric levels of benzo[a]pyrene (BaP), a representative marker, alongside urinary levels of 3-hydroxybenzo[a]pyrene (3-OHBaP), one of its metabolites. PAH exposure levels were monitored during seven sampling campaigns in four different factories specialized in heat-treatment of mechanical workpieces for the automotive and helicopter industries. Two types of furnace were studied, and 37 individuals were monitored. Values up to 20-fold the French regulatory value of 150 ng/m3 for atmospheric BaP, and, for urinary 3-OHBaP values up to 40-fold the French biological limit value (BLV) of 0.35 nmol/mol of creatinine were detected. Very high concentrations of BaP, close to or even exceeding those found in coal-tar pitch (up to about 20 g/kg), were measured in residues (tars, dusts) deposited inside the furnace. Even when adequate and suitable personal protective equipment was used, urinary 3-OHBaP values often exceeded the BLV. We hypothesize that this exposure is linked to insidious and fortuitous dermal contamination through contact with factory equipment and staining.
- 9 January 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (3) , 321-332
Open AccessMaintenance of Low-Pressure Carburising Furnaces: A Source of PAH Exposure
Low-pressure carburising is a new technology used to harden steel; the process has been shown to be a source of considerable polycyclic aromatic hydrocarbons (PAH) pollution. Some PAH are carcinogenic, and activities such as furnace maintenance may thus represent a risk to workers. Occupational exposure during these operations should therefore be assessed. In this study, the PAH-related carcinogenic risk associated with furnace maintenance was assessed by monitoring atmospheric levels of benzo[a]pyrene (BaP), a representative marker, alongside urinary levels of 3-hydroxybenzo[a]pyrene (3-OHBaP), one of its metabolites. PAH exposure levels were monitored during seven sampling campaigns in four different factories specialized in heat-treatment of mechanical workpieces for the automotive and helicopter industries. Two types of furnace were studied, and 37 individuals were monitored. Values up to 20-fold the French regulatory value of 150 ng/m3 for atmospheric BaP, and, for urinary 3-OHBaP values up to 40-fold the French biological limit value (BLV) of 0.35 nmol/mol of creatinine were detected. Very high concentrations of BaP, close to or even exceeding those found in coal-tar pitch (up to about 20 g/kg), were measured in residues (tars, dusts) deposited inside the furnace. Even when adequate and suitable personal protective equipment was used, urinary 3-OHBaP values often exceeded the BLV. We hypothesize that this exposure is linked to insidious and fortuitous dermal contamination through contact with factory equipment and staining.