Joerg Hausdorf
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Joerg Hausdorf has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Carl D. Reimers
Paracelsus-Kliniken Bremen
2 shared publicationsM. Maier
2 shared publications- Mareen Sarah Kraus
IWK Health, Halifax, NS, Canada
2 shared publications Markus Maier
Orthopaedic Department, Campus Großhadern, Ludwig-Maximilians-University Munich, Marchioninistr. 15, 81377 Munich, Germany
2 shared publications- Sasan Partovi
Department of Radiology, Section of Interventional Radiology, University Hospitals Cleveland Medical Center, Case Western Reserve University, Cleveland, OH, USA
2 shared publications V. Jansson
2 shared publications
Latest Publications
- 3 July 2018
- Published by Springer Nature
- p. 131-136
Osteoporose
- 3 July 2018
- Published by Springer Nature
- p. 125-130
Hüft- und Kniearthrose (Kox- und Gonarthrose) und Endoprothesen
- 3 July 2018
- Published by Springer Nature
- p. 125-130
Hüft- und Kniearthrose (Kox- und Gonarthrose) und Endoprothesen
- 12 January 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 47 (6) , 811-819
MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences
To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference.
- 12 January 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 47 (6) , 811-819
MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences
To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference.
- Open Access
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
MR Arthrography of the Hip: Diagnostic Performance and Image Quality of 3D Steady-State Free Precession versus 2D Turbo Spin-Echo Sequences
Introduction: To compare the diagnostic performance and image quality of an isotropic three-dimensional (3D) steady-state free precession (SSFP) sequence with the current diagnostic standard two-dimensional (2D) proton-density (PD)-weighted turbo spin-echo (TSE) protocol in hip magnetic resonance arthrography (MRA) with arthroscopy as a standard of reference. Materials and Methods: A total of 81 patients (age: 39.5 ± 11.1 years) with hip pain and suspected labral tears were included and underwent hip MRA with intra-articular contrast media on a 3-T scanner. Two-dimensional PD-weighted TSE was acquired in the axial, coronal, and sagittal planes (total acquisition time: 10 minutes) in keeping with the current diagnostic standard and a parasagittal 3D SSFP sequence (total acquisition time: 5.34 minutes). MRI data were reviewed independently regarding labral tears, cartilage pathology, and bone marrow edema by two blinded experienced musculoskeletal radiologists. Lesion detection and image quality were assessed using a 5-point Likert scale. In 39 patients, diagnostic accuracy of the two assessed sequences could be determined using invasive arthroscopy as the gold standard. Results: Based on image quality, diagnostic confidence when evaluating the labrum and cartilage was rated higher by both readers for the 3D SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001) compared with the 2D TSE-PD sequence. In the subset of patients with invasive arthroscopy, a similar sensitivity (81.3% and 90.6%) but higher specificity (74.4% for both) in the evaluation of labral tears and cartilage alterations was found for the 3D SSFP sequence versus the 2D TSE-PD sequences (sensitivity: 84.4 and 87.5%; specificity: 42.9%). For bone marrow evaluation, both readers rated diagnostic confidence based on image quality of the 2D TSE-PD sequence higher compared with the 3D SSFP sequence (p < 0.0001). Conclusion: In MR hip arthrography, a 3D SSFP sequence offers increased accuracy in the detection of labral tears and cartilage alterations compared with the current diagnostic standard 2D TSE-PD sequences. At the same time it also offers a higher time efficiency of MRI. A major drawback of 3D SSFP compared with 2D TSE-PD was the inferior diagnostic confidence for the evaluation of bone marrow. Thus 3D SSFP should still be combined with conventional 2D TSE sequences.
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
Open AccessMR Arthrography of the Hip: Diagnostic Performance and Image Quality of 3D Steady-State Free Precession versus 2D Turbo Spin-Echo Sequences
Introduction: To compare the diagnostic performance and image quality of an isotropic three-dimensional (3D) steady-state free precession (SSFP) sequence with the current diagnostic standard two-dimensional (2D) proton-density (PD)-weighted turbo spin-echo (TSE) protocol in hip magnetic resonance arthrography (MRA) with arthroscopy as a standard of reference. Materials and Methods: A total of 81 patients (age: 39.5 ± 11.1 years) with hip pain and suspected labral tears were included and underwent hip MRA with intra-articular contrast media on a 3-T scanner. Two-dimensional PD-weighted TSE was acquired in the axial, coronal, and sagittal planes (total acquisition time: 10 minutes) in keeping with the current diagnostic standard and a parasagittal 3D SSFP sequence (total acquisition time: 5.34 minutes). MRI data were reviewed independently regarding labral tears, cartilage pathology, and bone marrow edema by two blinded experienced musculoskeletal radiologists. Lesion detection and image quality were assessed using a 5-point Likert scale. In 39 patients, diagnostic accuracy of the two assessed sequences could be determined using invasive arthroscopy as the gold standard. Results: Based on image quality, diagnostic confidence when evaluating the labrum and cartilage was rated higher by both readers for the 3D SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001) compared with the 2D TSE-PD sequence. In the subset of patients with invasive arthroscopy, a similar sensitivity (81.3% and 90.6%) but higher specificity (74.4% for both) in the evaluation of labral tears and cartilage alterations was found for the 3D SSFP sequence versus the 2D TSE-PD sequences (sensitivity: 84.4 and 87.5%; specificity: 42.9%). For bone marrow evaluation, both readers rated diagnostic confidence based on image quality of the 2D TSE-PD sequence higher compared with the 3D SSFP sequence (p < 0.0001). Conclusion: In MR hip arthrography, a 3D SSFP sequence offers increased accuracy in the detection of labral tears and cartilage alterations compared with the current diagnostic standard 2D TSE-PD sequences. At the same time it also offers a higher time efficiency of MRI. A major drawback of 3D SSFP compared with 2D TSE-PD was the inferior diagnostic confidence for the evaluation of bone marrow. Thus 3D SSFP should still be combined with conventional 2D TSE sequences.
- 22 August 2010
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (3) , 303-309
Stimulation of bone growth factor synthesis in human osteoblasts and fibroblasts after extracorporeal shock wave application
Nonunion is a common problem in Orthopedic Surgery. In the recent years alternatives to the standard surgical procedures were tested clinically and in vitro. Extracorporeal shock wave therapy (ESWT) showed promising results in both settings. We hypothesized that in target tissue cells from nonunions like fibroblasts and osteoblasts ESWT increases the release of bone growth factors. Fibroblasts and osteoblasts were suspended in 3 ml cryotubes and subjected to 250/500 shock waves at 25 kV using an experimental electrohydraulic lithotripter. After ESWT, cell viability was determined and cells were seeded at 1 × 105 cells in 12 well plates. After 24, 48, and 72 h cell number was determined and supernatant was frozen. The levels of growth factors FGF-2 and TGF-β1 were examined using ELISA. A control group was treated equally without receiving ESWT. After 24 h there was a significant increase in FGF-2 levels (p < 0.05) with significant correlation to the number of impulses (p < 0.05) observed. TGF-β1 showed a time-dependent increase with a peak at 48 h which was not significantly different from the control group. FGF-2, an important growth factor in new bone formation, was shown to be produced by human fibroblasts and osteoblasts after treatment with ESWT. These findings demonstrate that ESWT is able to cause bone healing through a molecular way by inducing growth factor synthesis.
- 22 August 2010
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (3) , 303-309
Stimulation of bone growth factor synthesis in human osteoblasts and fibroblasts after extracorporeal shock wave application
Nonunion is a common problem in Orthopedic Surgery. In the recent years alternatives to the standard surgical procedures were tested clinically and in vitro. Extracorporeal shock wave therapy (ESWT) showed promising results in both settings. We hypothesized that in target tissue cells from nonunions like fibroblasts and osteoblasts ESWT increases the release of bone growth factors. Fibroblasts and osteoblasts were suspended in 3 ml cryotubes and subjected to 250/500 shock waves at 25 kV using an experimental electrohydraulic lithotripter. After ESWT, cell viability was determined and cells were seeded at 1 × 105 cells in 12 well plates. After 24, 48, and 72 h cell number was determined and supernatant was frozen. The levels of growth factors FGF-2 and TGF-β1 were examined using ELISA. A control group was treated equally without receiving ESWT. After 24 h there was a significant increase in FGF-2 levels (p < 0.05) with significant correlation to the number of impulses (p < 0.05) observed. TGF-β1 showed a time-dependent increase with a peak at 48 h which was not significantly different from the control group. FGF-2, an important growth factor in new bone formation, was shown to be produced by human fibroblasts and osteoblasts after treatment with ESWT. These findings demonstrate that ESWT is able to cause bone healing through a molecular way by inducing growth factor synthesis.
- 1 August 2010
- Published by Elsevier in Journal of Biomechanics
- Vol. 43 (11) , 2065-2069
Shock wave therapy for femoral head necrosis—Pressure measurements inside the femoral head
- 1 August 2010
- Published by Elsevier in Journal of Biomechanics
- Vol. 43 (11) , 2065-2069
Shock wave therapy for femoral head necrosis—Pressure measurements inside the femoral head
- 29 September 2007
- Published by Springer Nature in Der Orthopäde
- Vol. 36 (10) , 944-949
Die luxierte Schulterprothese – eine vermeidbare Katastrophe?
- 29 September 2007
- Published by Springer Nature in Der Orthopäde
- Vol. 36 (10) , 944-949
Die luxierte Schulterprothese – eine vermeidbare Katastrophe?
- 1 April 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 117 (4_Suppleme) , 2369
Extracorporeal shock wave therapy in orthopedics, basic research, and clinical implications
- 1 April 2005
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 117 (4_Suppleme) , 2369
Extracorporeal shock wave therapy in orthopedics, basic research, and clinical implications
- 1 November 2004
- Published by Springer Nature in Der Schmerz
- Vol. 18 (6) , 492-497
Molekulare Grundlagen zur schmerzvermittelnden Wirkung extrakorporaler Sto wellen
- 1 November 2004
- Published by Springer Nature in Der Schmerz
- Vol. 18 (6) , 492-497
Molekulare Grundlagen zur schmerzvermittelnden Wirkung extrakorporaler Sto wellen