Sasan Partovi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sasan Partovi has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Joerg Hausdorf
Ärztehaus Harlaching
2 shared publications - Konstantin Nikolaou
Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, Hoppe-Seyler-Straße 3, 72076 Tuebingen, Germany
2 shared publications - Mareen Sarah Kraus
IWK Health, Halifax, NS, Canada
2 shared publications - Nicholas Bhojwani
HonorHealth, 10835 North 25th Avenue #240, Phoenix, AZ 85029, USA
2 shared publications - Roland Syha
Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
2 shared publications - Ahmed Sobieh
Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
1 shared publication
Latest Publications
- Open Access
- 2 May 2018
- Published by Springer Nature in Cancer Imaging
- Vol. 18 (1) , 16
Image quality of arterial phase and parenchymal blood volume (PBV) maps derived from C-arm computed tomography in the evaluation of transarterial chemoembolization
To evaluate the benefits of arterial phase imaging and parenchymal blood volume (PBV) maps acquired by C-arm computed tomography during TACE procedure in comparison to cross-sectional imaging (CSI) using CT or MRI. From January 2014 to December 2016, a total of 29 patients with HCC stage A or B (mean age 65 years; range 47 to 81 years, 86% male) were included in this study. These patients were referred to our department for TACE treatment and received peri-interventional C-arm CT. Dual phase findings of each lesion in terms of overall image quality, conspicuity, tumor size and feeding arteries were compared between arterial phase imaging and PBV using 5-point semi-quantitative Likert-scale, whereby pre-interventional CSI served as reference standard. A significantly higher overall image quality of the PBV maps compared to arterial phase C-arm CT acquisitions (4.34 (±0.55) vs. 3.93 (±0.59), p = 0.0032) as well as a higher conspicuity of HCC lesions (4.27 ± 0.74 vs. 3.83 ± 1.08, p < 0.0001) was observed. Arterial phase imaging led to an overestimation of tumor size (mean size, 26.5 ± 15.9 mm) compared to PBV (24.9 ± 15.2 mm, p = 0.0004) as well as CSI (25.2 ± 15.1 mm), p = 0.021). Regarding detectability of tumor feeding arterial vessels, significantly more feeding vessels were detected in arterial phase C-arm CT (n = 1.67 ± 0.92 vessels) compared to PBV maps (n = 1.27 ± 0.63 vessels) (p = 0.0001). One lesion was missed in pre-interventional CT imaging, but detected by C-arm CT. The combination of PBV maps and arterial phase images acquired by C-arm CT during TACE procedure enables precise detection of the majority of HCC lesions and tumor feeding arteries and has therefore the potential to improve patient outcome.
- 2 May 2018
- Published by Springer Nature in Cancer Imaging
- Vol. 18 (1) , 16
Open AccessImage quality of arterial phase and parenchymal blood volume (PBV) maps derived from C-arm computed tomography in the evaluation of transarterial chemoembolization
To evaluate the benefits of arterial phase imaging and parenchymal blood volume (PBV) maps acquired by C-arm computed tomography during TACE procedure in comparison to cross-sectional imaging (CSI) using CT or MRI. From January 2014 to December 2016, a total of 29 patients with HCC stage A or B (mean age 65 years; range 47 to 81 years, 86% male) were included in this study. These patients were referred to our department for TACE treatment and received peri-interventional C-arm CT. Dual phase findings of each lesion in terms of overall image quality, conspicuity, tumor size and feeding arteries were compared between arterial phase imaging and PBV using 5-point semi-quantitative Likert-scale, whereby pre-interventional CSI served as reference standard. A significantly higher overall image quality of the PBV maps compared to arterial phase C-arm CT acquisitions (4.34 (±0.55) vs. 3.93 (±0.59), p = 0.0032) as well as a higher conspicuity of HCC lesions (4.27 ± 0.74 vs. 3.83 ± 1.08, p < 0.0001) was observed. Arterial phase imaging led to an overestimation of tumor size (mean size, 26.5 ± 15.9 mm) compared to PBV (24.9 ± 15.2 mm, p = 0.0004) as well as CSI (25.2 ± 15.1 mm), p = 0.021). Regarding detectability of tumor feeding arterial vessels, significantly more feeding vessels were detected in arterial phase C-arm CT (n = 1.67 ± 0.92 vessels) compared to PBV maps (n = 1.27 ± 0.63 vessels) (p = 0.0001). One lesion was missed in pre-interventional CT imaging, but detected by C-arm CT. The combination of PBV maps and arterial phase images acquired by C-arm CT during TACE procedure enables precise detection of the majority of HCC lesions and tumor feeding arteries and has therefore the potential to improve patient outcome.
- 12 January 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 47 (6) , 811-819
MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences
To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference.
- 12 January 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 47 (6) , 811-819
MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences
To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference.
- 1 May 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1073) , 20160130
Imaging of musculoskeletal manifestations in sickle cell disease patients
Sickle cell disease (SCD) is a hereditary red cell disorder with clinical manifestations secondary to sickling or crescent-shaped distortion of the red blood cells. Major clinical manifestations of SCD include haemolytic anaemia and vaso-occlusive phenomena resulting in ischaemic tissue injury and organ damage. Chronic sequelae of the anaemia and vaso-occlusive processes involving the musculoskeletal system include complications related to extramedullary haematopoiesis, osteonecrosis, myonecrosis and osteomyelitis. Sickle cell bone disease is one of the commonest clinical presentations. Awareness and knowledge of the imaging features related to these complications are essential for early diagnosis and prompt management. In this article, the pathophysiology and key imaging findings related to these complications are reviewed.
- 1 May 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1073) , 20160130
Imaging of musculoskeletal manifestations in sickle cell disease patients
Sickle cell disease (SCD) is a hereditary red cell disorder with clinical manifestations secondary to sickling or crescent-shaped distortion of the red blood cells. Major clinical manifestations of SCD include haemolytic anaemia and vaso-occlusive phenomena resulting in ischaemic tissue injury and organ damage. Chronic sequelae of the anaemia and vaso-occlusive processes involving the musculoskeletal system include complications related to extramedullary haematopoiesis, osteonecrosis, myonecrosis and osteomyelitis. Sickle cell bone disease is one of the commonest clinical presentations. Awareness and knowledge of the imaging features related to these complications are essential for early diagnosis and prompt management. In this article, the pathophysiology and key imaging findings related to these complications are reviewed.
- Open Access
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
MR Arthrography of the Hip: Diagnostic Performance and Image Quality of 3D Steady-State Free Precession versus 2D Turbo Spin-Echo Sequences
Introduction: To compare the diagnostic performance and image quality of an isotropic three-dimensional (3D) steady-state free precession (SSFP) sequence with the current diagnostic standard two-dimensional (2D) proton-density (PD)-weighted turbo spin-echo (TSE) protocol in hip magnetic resonance arthrography (MRA) with arthroscopy as a standard of reference. Materials and Methods: A total of 81 patients (age: 39.5 ± 11.1 years) with hip pain and suspected labral tears were included and underwent hip MRA with intra-articular contrast media on a 3-T scanner. Two-dimensional PD-weighted TSE was acquired in the axial, coronal, and sagittal planes (total acquisition time: 10 minutes) in keeping with the current diagnostic standard and a parasagittal 3D SSFP sequence (total acquisition time: 5.34 minutes). MRI data were reviewed independently regarding labral tears, cartilage pathology, and bone marrow edema by two blinded experienced musculoskeletal radiologists. Lesion detection and image quality were assessed using a 5-point Likert scale. In 39 patients, diagnostic accuracy of the two assessed sequences could be determined using invasive arthroscopy as the gold standard. Results: Based on image quality, diagnostic confidence when evaluating the labrum and cartilage was rated higher by both readers for the 3D SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001) compared with the 2D TSE-PD sequence. In the subset of patients with invasive arthroscopy, a similar sensitivity (81.3% and 90.6%) but higher specificity (74.4% for both) in the evaluation of labral tears and cartilage alterations was found for the 3D SSFP sequence versus the 2D TSE-PD sequences (sensitivity: 84.4 and 87.5%; specificity: 42.9%). For bone marrow evaluation, both readers rated diagnostic confidence based on image quality of the 2D TSE-PD sequence higher compared with the 3D SSFP sequence (p < 0.0001). Conclusion: In MR hip arthrography, a 3D SSFP sequence offers increased accuracy in the detection of labral tears and cartilage alterations compared with the current diagnostic standard 2D TSE-PD sequences. At the same time it also offers a higher time efficiency of MRI. A major drawback of 3D SSFP compared with 2D TSE-PD was the inferior diagnostic confidence for the evaluation of bone marrow. Thus 3D SSFP should still be combined with conventional 2D TSE sequences.
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
Open AccessMR Arthrography of the Hip: Diagnostic Performance and Image Quality of 3D Steady-State Free Precession versus 2D Turbo Spin-Echo Sequences
Introduction: To compare the diagnostic performance and image quality of an isotropic three-dimensional (3D) steady-state free precession (SSFP) sequence with the current diagnostic standard two-dimensional (2D) proton-density (PD)-weighted turbo spin-echo (TSE) protocol in hip magnetic resonance arthrography (MRA) with arthroscopy as a standard of reference. Materials and Methods: A total of 81 patients (age: 39.5 ± 11.1 years) with hip pain and suspected labral tears were included and underwent hip MRA with intra-articular contrast media on a 3-T scanner. Two-dimensional PD-weighted TSE was acquired in the axial, coronal, and sagittal planes (total acquisition time: 10 minutes) in keeping with the current diagnostic standard and a parasagittal 3D SSFP sequence (total acquisition time: 5.34 minutes). MRI data were reviewed independently regarding labral tears, cartilage pathology, and bone marrow edema by two blinded experienced musculoskeletal radiologists. Lesion detection and image quality were assessed using a 5-point Likert scale. In 39 patients, diagnostic accuracy of the two assessed sequences could be determined using invasive arthroscopy as the gold standard. Results: Based on image quality, diagnostic confidence when evaluating the labrum and cartilage was rated higher by both readers for the 3D SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001) compared with the 2D TSE-PD sequence. In the subset of patients with invasive arthroscopy, a similar sensitivity (81.3% and 90.6%) but higher specificity (74.4% for both) in the evaluation of labral tears and cartilage alterations was found for the 3D SSFP sequence versus the 2D TSE-PD sequences (sensitivity: 84.4 and 87.5%; specificity: 42.9%). For bone marrow evaluation, both readers rated diagnostic confidence based on image quality of the 2D TSE-PD sequence higher compared with the 3D SSFP sequence (p < 0.0001). Conclusion: In MR hip arthrography, a 3D SSFP sequence offers increased accuracy in the detection of labral tears and cartilage alterations compared with the current diagnostic standard 2D TSE-PD sequences. At the same time it also offers a higher time efficiency of MRI. A major drawback of 3D SSFP compared with 2D TSE-PD was the inferior diagnostic confidence for the evaluation of bone marrow. Thus 3D SSFP should still be combined with conventional 2D TSE sequences.
- 26 June 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 40 (6) , 1415-1425
Comparison of hybrid FDG PET/MRI compared with PET/CT in colorectal cancer staging and restaging: a pilot study
We report our initial clinical experience from a pilot study to compare the diagnostic accuracy of hybrid PET/MRI with PET/CT in colorectal cancer and discuss potential PET/MRI workflow solutions for colorectal cancer. Patients underwent both FDG PET/CT and PET/MRI (Ingenuity TF PET/MRI, Philips Healthcare) for rectal cancer staging or colorectal cancer restaging. The PET acquisition of PET/MRI was similar to that of PET/CT whereas the MRI protocol was selected individually based on the patient’s medical history. One nuclear medicine physician reviewed the PET/CT studies and one radiologist reviewed the PET/MRI studies independently. The diagnostic accuracy of each modality was determined in consensus, using available medical records as a reference. Of the 12 patients enrolled, two were for initial staging and ten for restaging. The median scan delay between the two modalities was 60 min. The initial imaging was PET/CT in nine patients and PET/MRI in three patients. When PET/CT was performed first, the SUV values of the 16 FDG avid lesions were greater at PET/MRI than at PET/CT. In contrast, when PET/MRI was performed first, the SUV values of the seven FDG avid lesions were greater at PET/CT than at PET/MRI. PET/MRI provided more detailed T staging than PET/CT. On a per-patient basis, with both patient groups combined for the evaluation of N and M staging/restaging, the true positive rate was 5/7 (71%) for PET/CT and 6/7 (86%) for PET/MRI, and true negative rate was 5/5 (100%) for both modalities. On a per-lesion basis, PET/CT identified 26 of 29 (90%) tumor lesions that were correctly detected by PET/MRI. Our proposed workflow allows for comprehensive cancer staging including integrated local and whole-body assessment. Our initial experience shows a high diagnostic accuracy of PET/MRI in T staging of rectal cancer compared with PET/CT. In addition, PET/MRI shows at least comparable accuracy in N and M staging as well as restaging to PET/CT. However, the small sample size limits the generalizability of the results. It is expected that PET/MRI would yield higher diagnostic accuracy than PET/CT considering the high soft tissue contrast provided by MRI compared with CT, but larger studies are necessary to fully assess the benefit of PET/MRI in colorectal cancer.
- 26 June 2015
- Published by Springer Nature in Abdominal Radiology
- Vol. 40 (6) , 1415-1425
Comparison of hybrid FDG PET/MRI compared with PET/CT in colorectal cancer staging and restaging: a pilot study
We report our initial clinical experience from a pilot study to compare the diagnostic accuracy of hybrid PET/MRI with PET/CT in colorectal cancer and discuss potential PET/MRI workflow solutions for colorectal cancer. Patients underwent both FDG PET/CT and PET/MRI (Ingenuity TF PET/MRI, Philips Healthcare) for rectal cancer staging or colorectal cancer restaging. The PET acquisition of PET/MRI was similar to that of PET/CT whereas the MRI protocol was selected individually based on the patient’s medical history. One nuclear medicine physician reviewed the PET/CT studies and one radiologist reviewed the PET/MRI studies independently. The diagnostic accuracy of each modality was determined in consensus, using available medical records as a reference. Of the 12 patients enrolled, two were for initial staging and ten for restaging. The median scan delay between the two modalities was 60 min. The initial imaging was PET/CT in nine patients and PET/MRI in three patients. When PET/CT was performed first, the SUV values of the 16 FDG avid lesions were greater at PET/MRI than at PET/CT. In contrast, when PET/MRI was performed first, the SUV values of the seven FDG avid lesions were greater at PET/CT than at PET/MRI. PET/MRI provided more detailed T staging than PET/CT. On a per-patient basis, with both patient groups combined for the evaluation of N and M staging/restaging, the true positive rate was 5/7 (71%) for PET/CT and 6/7 (86%) for PET/MRI, and true negative rate was 5/5 (100%) for both modalities. On a per-lesion basis, PET/CT identified 26 of 29 (90%) tumor lesions that were correctly detected by PET/MRI. Our proposed workflow allows for comprehensive cancer staging including integrated local and whole-body assessment. Our initial experience shows a high diagnostic accuracy of PET/MRI in T staging of rectal cancer compared with PET/CT. In addition, PET/MRI shows at least comparable accuracy in N and M staging as well as restaging to PET/CT. However, the small sample size limits the generalizability of the results. It is expected that PET/MRI would yield higher diagnostic accuracy than PET/CT considering the high soft tissue contrast provided by MRI compared with CT, but larger studies are necessary to fully assess the benefit of PET/MRI in colorectal cancer.
- 1 May 2015
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 53 (3) , 549-567
Advanced Noncontrast MR Imaging in Musculoskeletal Radiology
- 1 May 2015
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 53 (3) , 549-567
Advanced Noncontrast MR Imaging in Musculoskeletal Radiology