Ahmad Gholami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmad Gholami has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Reza Tayebi
Jahad Daneshgahi Elm va Sanat, Narmak, Tehran, Iran
3 shared publications - Abolfazl Vahedi
Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
2 shared publications - M. Mirzaie
Iran University of Science and Technology, P.O. Box # 16844, Narmak, Tehran, Iran; Mazandaran University, Narmak, Tehran, Iran. Fax # +9821 77240490
2 shared publications - Omid Homaee
Department of Electrical Engineering Fundamentals, Faculty of Electrical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland
2 shared publications - Alireza Sobbouhi
Electrical Engineering Department, Shahid Beheshti University, Tehran, Iran
1 shared publication - Heidarali Shayanfar
Center of Excellence for Power Systems Automation and Operation School of Electrical Engineering Iran University of Science and Technology Tehran Iran
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (1) , 265-280
Experimental Evaluation and Finite Element Modelling of the Effect of Aging on Dry-band Discharge Intensity in Polluted Polymer Insulators
Aging and loss of hydrophobicity are among the most significant challenges in using polymer insulators in highly polluted areas. This leads to an increase in leakage current (LC) and the occurrence of dry band discharge (DBD) phenomena on the surface of the insulator, which may ultimately result in flashover and fault. This paper investigates the effect of aging on the intensity of DBD in polymer insulators. To this end, five sample insulators of varying ages were collected from a medium voltage distribution network, and after applying artificial pollution, their LCs were recorded in a fog chamber under nominal voltage conditions. Additionally, magnitude and duration of discharge were extracted from the LC signals and proposed as two indices for evaluating the aging of the insulators. Furthermore, a novel method for finite element modelling of polluted polymer insulators is presented. In the proposed method, the phenomenon of DBD in the pollution layer and the effect of insulator aging on the intensity of this phenomenon have been implemented. For this purpose, the electrical conductivity of the pollution layer is considered to be dynamic and a function of the electric field at the surface of the insulator. The parameters of the conductivity-field curve were calculated through low-voltage test and utilized in the simulations. The results of the finite element modelling are in accordance with test results and demonstrate an increase in the intensity of DBD with insulator aging.
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (1) , 265-280
Open AccessExperimental Evaluation and Finite Element Modelling of the Effect of Aging on Dry-band Discharge Intensity in Polluted Polymer Insulators
Aging and loss of hydrophobicity are among the most significant challenges in using polymer insulators in highly polluted areas. This leads to an increase in leakage current (LC) and the occurrence of dry band discharge (DBD) phenomena on the surface of the insulator, which may ultimately result in flashover and fault. This paper investigates the effect of aging on the intensity of DBD in polymer insulators. To this end, five sample insulators of varying ages were collected from a medium voltage distribution network, and after applying artificial pollution, their LCs were recorded in a fog chamber under nominal voltage conditions. Additionally, magnitude and duration of discharge were extracted from the LC signals and proposed as two indices for evaluating the aging of the insulators. Furthermore, a novel method for finite element modelling of polluted polymer insulators is presented. In the proposed method, the phenomenon of DBD in the pollution layer and the effect of insulator aging on the intensity of this phenomenon have been implemented. For this purpose, the electrical conductivity of the pollution layer is considered to be dynamic and a function of the electric field at the surface of the insulator. The parameters of the conductivity-field curve were calculated through low-voltage test and utilized in the simulations. The results of the finite element modelling are in accordance with test results and demonstrate an increase in the intensity of DBD with insulator aging.
- 22 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1590-1593
A Conservative Approach for Investigation of Transient Overvoltage Acceptability in Customers’ Terminals by Considering Voltage Vulnerability Curves of Customers
The main goal of this paper is introducing a new method for analyzing of vulnerability of costumers' equipment due to the transient over voltages. For this purpose, a method by using the cumulative curve of transient voltages in the customer terminal is proposed. By comprising of this curve with subscription of customers' acceptable voltage curves, the safety operation of customers in the presence of over voltages will be guaranteed.
- 22 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1590-1593
A Conservative Approach for Investigation of Transient Overvoltage Acceptability in Customers’ Terminals by Considering Voltage Vulnerability Curves of Customers
The main goal of this paper is introducing a new method for analyzing of vulnerability of costumers' equipment due to the transient over voltages. For this purpose, a method by using the cumulative curve of transient voltages in the customer terminal is proposed. By comprising of this curve with subscription of customers' acceptable voltage curves, the safety operation of customers in the presence of over voltages will be guaranteed.
- 1 January 2017
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 25 (3) , 2322-2335
Dynamic model to predict AC critical flashover voltage of nonuniformly polluted insulators under thermal ionization conditions
- 1 January 2017
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 25 (3) , 2322-2335
Dynamic model to predict AC critical flashover voltage of nonuniformly polluted insulators under thermal ionization conditions
- 26 May 2010
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 38 (7) , 820-831
Calculation of Voltage Distribution along Porcelain Suspension Insulators Based on Finite Element Method
Porcelain string insulators are widely used in high-voltage transmission lines. Calculation of potential distribution is extensively performed in the design and development of high-voltage insulators. This article applies a three-dimensional electromagnetic analysis program to calculate the potential distribution of 230-kV porcelain suspension insulators under clean and dry conditions. The effects of cross-arm length, number of units, corona ring parameters, and also effects of wind force on the potential distribution along the porcelain suspension insulators are investigated and discussed. The results are useful for analyzing the potential distribution for porcelain suspension insulators.
- 26 May 2010
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 38 (7) , 820-831
Calculation of Voltage Distribution along Porcelain Suspension Insulators Based on Finite Element Method
Porcelain string insulators are widely used in high-voltage transmission lines. Calculation of potential distribution is extensively performed in the design and development of high-voltage insulators. This article applies a three-dimensional electromagnetic analysis program to calculate the potential distribution of 230-kV porcelain suspension insulators under clean and dry conditions. The effects of cross-arm length, number of units, corona ring parameters, and also effects of wind force on the potential distribution along the porcelain suspension insulators are investigated and discussed. The results are useful for analyzing the potential distribution for porcelain suspension insulators.
- 1 January 2009
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 17 (1) , 39-54
Insulation Condition Assessment of Power Transformers Using Accelerated Ageing Tests
Thermal stress due to losses and environment temperature causes degradation to paper/oil insulation systems in transformers, even at operating temperature. Experience indicates that thermal ageing of oil and paper in power transformers leads to the change of some insulation characteristics. In this paper, insulating papers immersed in oil have been acceleratory aged at 140, 150, and 160 °C under laboratory conditions. Some of the oil properties, such as water content, breakdown voltage, acidity, together with the aged insulating paper properties such as electric strength, dielectric dissipation factor and tensile strength were measured and analyzed. Also, insulation system conditions under thermal stress have been evaluated by electrical/distinctive techniques like recovery voltage, polarization and depolarization currents. Correlations between these parameters have been investigated. Finally, paper tensile strength has been used as a criterion to estimation of insulating paper life time.
- 1 January 2009
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 17 (1) , 39-54
Insulation Condition Assessment of Power Transformers Using Accelerated Ageing Tests
Thermal stress due to losses and environment temperature causes degradation to paper/oil insulation systems in transformers, even at operating temperature. Experience indicates that thermal ageing of oil and paper in power transformers leads to the change of some insulation characteristics. In this paper, insulating papers immersed in oil have been acceleratory aged at 140, 150, and 160 °C under laboratory conditions. Some of the oil properties, such as water content, breakdown voltage, acidity, together with the aged insulating paper properties such as electric strength, dielectric dissipation factor and tensile strength were measured and analyzed. Also, insulation system conditions under thermal stress have been evaluated by electrical/distinctive techniques like recovery voltage, polarization and depolarization currents. Correlations between these parameters have been investigated. Finally, paper tensile strength has been used as a criterion to estimation of insulating paper life time.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 253-258
Study on the Behavior of Polluted Insulators Under Lightning Impulse Stress
This paper presents a method to determine leakage current and thermal losses on the polluted insulators under lightning stress based on equivalent electrical model using ATP software. Thickness of pollution layer and the ratio of pollution-covered length and also steepness of the impulse voltage can cause variations of the leakage current and thermal losses. The results demonstrate that leakage currents were dramatically increased under different pollution conditions. The consequential mathematical equations show that the rate of leakage current can be controlled by limiting of the length and thickness of pollution layer. Also the humidity evaporated from insulator's surface due to thermal losses can be determined.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00849162,p. 253-258
Study on the Behavior of Polluted Insulators Under Lightning Impulse Stress
This paper presents a method to determine leakage current and thermal losses on the polluted insulators under lightning stress based on equivalent electrical model using ATP software. Thickness of pollution layer and the ratio of pollution-covered length and also steepness of the impulse voltage can cause variations of the leakage current and thermal losses. The results demonstrate that leakage currents were dramatically increased under different pollution conditions. The consequential mathematical equations show that the rate of leakage current can be controlled by limiting of the length and thickness of pollution layer. Also the humidity evaporated from insulator's surface due to thermal losses can be determined.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 102-105
Life Time Estimation and Reliability Model for Cellulose Insulation
Since the life time estimation and prediction of materials/products is very time-consuming, so it is necessary to do accelerated tests. In this paper, accelerated thermal air ageing test has been carried out at three different temperatures, 120, 140 and 160 centigrade in the ageing time. Due to rather coordinated variations and correlate to time, tensile strength has been chosen as a significant indicator to determine the life time of paper insulations. Life time comes to an end when this parameter decreases to the half of its primary amount Therefore tensile strength test on cellulose paper insulation has been done in different thermal stresses and it has been used in new model of life time (or ageing) estimation. New life model has been formulated and called power-exponential model. This model in life time estimations obtained which have good accuracy in comparison to other models such as Arrhenius model. Also we show that is possible to estimation the reliability of paper insulation under thermal stress using this accelerated ageing test. Therefore exponential distribution that it is simple distribution and very common in reliability is used for application coupled with the new model.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 102-105
Life Time Estimation and Reliability Model for Cellulose Insulation
Since the life time estimation and prediction of materials/products is very time-consuming, so it is necessary to do accelerated tests. In this paper, accelerated thermal air ageing test has been carried out at three different temperatures, 120, 140 and 160 centigrade in the ageing time. Due to rather coordinated variations and correlate to time, tensile strength has been chosen as a significant indicator to determine the life time of paper insulations. Life time comes to an end when this parameter decreases to the half of its primary amount Therefore tensile strength test on cellulose paper insulation has been done in different thermal stresses and it has been used in new model of life time (or ageing) estimation. New life model has been formulated and called power-exponential model. This model in life time estimations obtained which have good accuracy in comparison to other models such as Arrhenius model. Also we show that is possible to estimation the reliability of paper insulation under thermal stress using this accelerated ageing test. Therefore exponential distribution that it is simple distribution and very common in reliability is used for application coupled with the new model.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 673-676
Thermal Degradation of Cellulose Paper Insulation in Power Transformers
This paper presents on experimental on cellulose paper insulation and mineral insulating oil in power transformers. These materials were aged in specially designed glass cells at 140,150and 160 centigrade for ageing times. These measurements show that the loss of strength results from level varies of carbon monoxide and carbon dioxide. Paper tensile strength when combined and correlated with the amount of carbon monoxide and carbon dioxide gases in oil provides a good assessment of the condition of transformers cellulose insulation. Also it is suggested that the loss of tensile strength would provide an end of life criterion for predicting insulating paper life. Therefore a new paper expected life time model is developed.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 673-676
Thermal Degradation of Cellulose Paper Insulation in Power Transformers
This paper presents on experimental on cellulose paper insulation and mineral insulating oil in power transformers. These materials were aged in specially designed glass cells at 140,150and 160 centigrade for ageing times. These measurements show that the loss of strength results from level varies of carbon monoxide and carbon dioxide. Paper tensile strength when combined and correlated with the amount of carbon monoxide and carbon dioxide gases in oil provides a good assessment of the condition of transformers cellulose insulation. Also it is suggested that the loss of tensile strength would provide an end of life criterion for predicting insulating paper life. Therefore a new paper expected life time model is developed.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-8
A Genetic Algorithm Approach for Identifying Synchronous Generator Parameters from Excitation Disturbance Test
This paper presents a genetic algorithm based technique for on-line estimation of synchronous generator parameters, using an excitation disturbance. To illustrate and verify the proposed algorithm, some excitation disturbance tests are conducted on an actual hydro generator. Machine response to the applied disturbance is processed by the proposed technique using genetic algorithm. The estimated values of the parameters are compared with manufacture's data and also validated by comparing measured and simulated d-axis and q- axis flux linkages.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-8
A Genetic Algorithm Approach for Identifying Synchronous Generator Parameters from Excitation Disturbance Test
This paper presents a genetic algorithm based technique for on-line estimation of synchronous generator parameters, using an excitation disturbance. To illustrate and verify the proposed algorithm, some excitation disturbance tests are conducted on an actual hydro generator. Machine response to the applied disturbance is processed by the proposed technique using genetic algorithm. The estimated values of the parameters are compared with manufacture's data and also validated by comparing measured and simulated d-axis and q- axis flux linkages.