OHOmid Homaee

Omid Homaee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Omid Homaee has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lightning Transients in Wind Turbines: A Study on How to Segmentize the Tower, Blades, and Grounding Rods

    by Mohammad Javad Nasiri, Omid Homaee, Ahmad Gholami, Michal Jasinski, Zbigniew Leonowicz

    Segmenting Wind Turbine's (WT) tower and blades has been widely used to increase the accuracy of lightning transient simulations. However, the impact of segmentation on precision and the optimal number of segments required for a specific accuracy level have not been thoroughly investigated. In this paper, at first, a formulation for calculating the characteristic impedance of blades' down conductors is analytically derived and verified based on the experimental data. Then, the electrical parameters of the WT's blades, as nonuniform transmission lines, are accurately calculated. A comprehensive analysis is then performed to examine how the number of segments in WT's blades, tower, and grounding systems affects transient voltages and currents created by lightning strikes. The investigation focuses on assessing the effects of the number of segments in terms of the generated overvoltage across various components, the Ground Potential Rise (GPR) values, and the energy absorbed by Surge Arresters (SA). The numerical studies reveal that the quantity of segments for each component significantly influences the outcomes of the lightning strike. For instance, the number of tower's segments mostly affects the overvoltage at the generator's terminal, while the number of ground's horizontal rod segments has the most impact on GPR. This study provides valuable insights into tailoring segmentation strategies for WT components, paving the way for more effective lightning protection simulation and design.


  • Application of Extreme Learning Machine- Autoencoder to Medium Term Electricity Price Forecasting

    by Arsalan Najafi, Omid Homaee, Mehdi Golshan, Michal Jasinski, Zbigniew Leonowicz

    Electricity market prices are highly volatile, highly frequent, non-linear, and non-stationary which makes forecasting very complicated. Although accurate forecasting plays a crucial role in the electricity market for traders, retailers, large consumers as well as generation companies in terms of economic efficiency and power systems safety. Hence, this paper proposes a new forecasting approach for medium-term electricity market prices based on an extreme learning machine-autoencoder (ELM-AE). The main idea behind this is to use trained weights for hidden layers instead of randomly generated weights. The input hidden layer weights are obtained by solving a network with the same input outputs by the autoencoder method. Then, the obtained output weights are used again as the input weights for a new ELM network. To do so, a data-set is created using input data, where the ahead 24 hours are forecasted based on the previous 168 data. The simulations have been performed on New York Independent System Operator prices and compared with the classic ELM demonstrating the high accuracy of the proposed method in both training and testing.


  • On the Forecastability of Solar Energy Generation by Rooftop Panels Pointed in Different Directions

    by Michal Jasinski, Omid Homaee, Daniel Opałkowski, Arsalan Najafi, Zbigniew Leonowicz

    By increasing the penetration of small-scale rooftop solar panels, forecasting their output has become important to both homeowners and distribution systems operators. In many areas, the roof of residential houses is not such that all solar panels are installed pointing in one direction; so, they are installed pointing in different directions. In this letter, the effect of this phenomenon on the forecastability of the day-ahead solar panels' power output is experimentally investigated. To perform day-ahead energy forecasting, a feedforward artificial neural network (ANN) is created using historical data and weather conditions of a similar day along with the forecast weather conditions of the day for which the forecast is to be performed. A similar day selection algorithm based on Euclidean distance is used to determine the reference day. Two forecasting approaches have been compared: forecasting each panel output and forecasting the total output. Moreover, Long short-term memory (LSTM) is used to validate the conclusion made by the feedforward ANN. The results evidently show that considering different directions of the solar panels increases the forecastability of the rooftop solar power plant.


  • Analyzing the Effect of Lightning Channel Impedance on the Lightning Overvoltages in Wind Turbines

    by Mohammad Javad Nasiri, Omid Homaee, Arsalan Najafi, Michal Jasinski, Zbigniew Leonowicz

    Lightning is a natural phenomenon that can cause serious damage to power systems including wind farms. Wind Turbines (WTs) are tall structures and are often installed in areas with high lightning activity levels which makes them exposed to direct strikes. One of the parameters affecting the performance of the lightning protection system is the impedance of the lightning channel. In this paper, the effects of this impedance on the lightning overvoltages in wind turbines, and the energy absorbed by Surge Arresters (SAs), as the main lightning protection device, are investigated. The case study is carried out on a WT with 2 MVA of rated power where a direct lightning strike with a maximum current magnitude of 50 kA is struck to one of the WT's blades. Accurate models, designed for transient studies, are used for modeling different parts of the WT. The results of different scenarios are compared, and it is shown that as the value of lightning channel impedance gets higher, the overvoltage caused by the corresponding lightning strike, with the same current magnitude, increases too. In addition, it is shown that the higher the lightning channel impedance, the higher the absorbed energy by the arrester. This shows the importance of the lightning channel impedance's effect on high-voltage studies of WTs, as it can help in selecting proper lightning protection devices.


  • Investigation of the impacts of the refill valve diameter on prestrike occurrence in gas circuit breakers

    by Omid Homaee, Ali Kazempour, Ahmad Gholami

    In puffer type Sulfur Hexafluoride (SF6) Circuit Breakers (CBs), the refill valve is the main inlet duct for the SF6 gas to enter the puffer volume. When the CB is closing and moving contacts and the nozzle are moving toward fixed contacts, the SF6 gas enters the puffer volume via the refill valve. Since changing the refill valve diameter can alter the direction of the SF6 gas motion in the closing operation of CBs, understanding its effects on CBs' function and performance may help to improve the CB design. This paper has focused on the effects of refill valve diameter on prestrike occurrence in the closing operation of puffer type SF6 CBs. In order to accurately study these effects, some equations are used in the developed multiphysics model, including the Navier–Stokes equations and standard K–ε turbulent model for modeling the motion of the SF6 gas, heat equation for calculation of the gas temperature, Maxwell equations for electromagnetic fields modeling, and gas state equation for taking into account the severe dependence of the SF6 gas properties on temperature. Numerical studies have been performed on a 72.5 kV CB. Performance and functionality of this CB have been investigated for four different refill valves from several physical aspects. Numerical studies show that the refill valve diameter has a considerable influence on the prestrike occurrence instant.


  • A Conservative Approach for Investigation of Transient Overvoltage Acceptability in Customers’ Terminals by Considering Voltage Vulnerability Curves of Customers

    by Omid Homaee, Alireza Sobbouhi, Ahmad Gholami, Abolfazl Vahedi

    The main goal of this paper is introducing a new method for analyzing of vulnerability of costumers' equipment due to the transient over voltages. For this purpose, a method by using the cumulative curve of transient voltages in the customer terminal is proposed. By comprising of this curve with subscription of customers' acceptable voltage curves, the safety operation of customers in the presence of over voltages will be guaranteed.


  • Open Access

    Investigation of synchronous generator in reactive power market – an accurate view

    by Omid Homaee, Shahram Jadid

    This study addresses clarification regarding total payment function calculation in reactive power market. One of the main sources of reactive power in transmission network is synchronous generator. Capability curves of reactive power produced by synchronous generators are surveyed in this study. Meanwhile, using these curves, all the costs of one synchronous generator to inject or absorb reactive power are calculated. These costs include an availability cost and cost of losses as well as cost of losing the sale opportunity of electrical energy because of production or absorption of reactive power. The IEEE 24‐bus reliability test system is used to illustrate the proposed cost calculation technique in reactive power market.


  • Real time voltage control using emergency demand response in distribution system by integrating advanced metering infrastructure

    by Omid Homaee, Alireza Zakariazadeh, Shahram Jadid

    In this paper, an analytical study is reported to demonstrate the effects of demand response on distribution network voltages profile. Also, a new approach for real time voltage control is proposed which uses emergency demand response program aiming at maintaining voltage profile in an acceptable range with minimum cost. This approach will be active in emergency conditions where, in real time, the voltages in some nodes leave their permissible ranges. These emergency conditions are Distributed Generation (DG) units and lines outage, and unpredictable demand and renewable generations' fluctuations. The proposed approach does not need the load and renewable generation forecast data to regulate voltage. To verify the effectiveness and robustness of the proposed control scheme, the proposed voltage control scheme is tested on a typical distribution network. The simulation results show the effectiveness and capability of the proposed real time voltage control model to maintain smart distribution network voltage in specified ranges in both normal and emergency conditions.


  • Optimal allocation of capacitors with stand-alone VAr control systems in radial distribution networks

    by Sina Moradian, Shahram Jadid, Omid Homaee

    A method for optimally sizing and placing switched capacitors with stand-alone VAr control systems and fixed capacitors in radial distribution networks is presented. Net savings is used as the objective function and is maximized using genetic algorithm as an optimization method. The proposed method is implemented for a 15-bus, an 85-bus, and a 28-bus distribution network. The results are compared with those of optimally placed capacitors with a universal control system. The importance of modeling the control system is established, and its implications on the amount of savings are studied. Copyright © 2014 John Wiley & Sons, Ltd.