JLJohn E. Lynch

John E. Lynch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John E. Lynch has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Monitoring Microemboli During Cardiopulmonary Bypass with the EDAC® Quantifier

    by Christopher Wells, Tom Akers, Paul Frantz, Donna Garrett, M. Lance Scott, Lisa Williamson, Barbara Agnew, John K. Lynch

    Gaseous emboli may be introduced into the bypass circuit both from the surgical field and during perfusionist interventions. While circuits provide good protection against massive air embolism, they do not remove gaseous microemboli (GME) from the bypass circuit. The purpose of this preliminary study is to assess the incidence of GME during bypass surgery and determine if increased GME counts were associated with specific events during bypass surgery. In 30 cases divided between 15 coronary artery bypass grafts and 15 valve repairs, GME were counted and sized at the three locations on the bypass circuit using the EDAC® Quantifier (Luna Innovations, Roanoke, VA). A mean of 45,276 GME were detected after the arterial line filter during these 30 cases, with significantly more detected (p= .04) post filter during valve cases (mean = 72,137 ± 22,113) than coronary artery bypass graft cases (mean = 18,416 ± 7831). GME detected post filter were significantly correlated in time with counts detected in the venous line (p< .001). Specific events associated with high counts included the initiation of cardiopulmonary bypass, heart manipulations, insertion and removal of clamps, and the administration of drugs. Global factors associated with increased counts post filter included higher venous line counts and higher post reservoir/bubble trap counts. The mean number of microemboli detected during bypass surgery was much higher than reported in other studies of emboli incidence, most likely due to the increased sensitivity of the EDAC® Quantifier compared to other detection modalities. The results furthermore suggest the need for further study of the clinical significance of these microemboli and what practices may be used to reduce GME incidence. Increased in vitro testing of the air handling capability of different circuit designs, along with more clinical studies assessing best clinical practices for reducing GME activity, is recommended.


  • Open Access

    Noninvasive monitoring of elevated intramuscular pressure in a model compartment syndrome via quantitative fascial motion

    by John E. Lynch, John K. Lynch, Steven L. Cole, Jonathan A. Carter, Alan R. Hargens

    Compartment syndromes, conditions of elevated intramuscular pressure (IMP) resulting from trauma or chronic overuse, frequently require invasive IMP monitoring for accurate diagnosis. Our objective was to test a noninvasive ultrasound technique for estimating IMP based on fascial displacement waveforms from arterial blood pressure pulses. IMP was increased in the legs of 23 healthy adult subjects up to 80 mmHg using two blood pressure cuffs covering the region from the knee to the ankle. Receiver operator characteristic curves and recursive partitioning were used to determine the sensitivity and specificity of diagnosing elevated IMP using fascial displacement. For one curve, in which several ultrasonic measurement parameters were used along with subject body mass index and blood pressure, the sensitivity and specificity for diagnosing normal IMP (below 30 mmHg) from elevated IMP (30 mmHg and up) was 0.61 and 0.94, respectively. Recursive partitioning, in which IMP was divided into three ranges (normal <30 mmHg, midrange of 30–40 mmHg, and elevated ≥50 mmHg), resulted in improved diagnostic sensitivity (0.77) with almost no change in specificity (0.93). © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 489–494, 2009


  • Microemboli detection on extracorporeal bypass circuitsa

    by Je Lynch, Jb Riley

    Numerous authors have associated gaseous microembolization with adverse cerebral outcomes during cardiopulmonary bypass (CPB). The introduction to this review provides background on the connection between microemboli and adverse cerebral outcomes. This connection is often difficult to quantify, as outcomes depend on a number of factors, including the size of the bubble, where it passes through the patient, patient co-morbidities and other factors. Nonetheless, numerous studies have shown statistically significant differences in the mean number of cerebral emboli detected in patients that stroked and those that did not, as well as for patients with major cardiac complications and patients with a longer length of hospital stay. Our introduction is followed by case reports and laboratory studies showing how monitoring for gaseous microemboli (GME) can be used to reduce the embolic load delivered to the patient through the bypass circuit. These methods include improved qualification of bypass circuit design prior to surgery, modification of priming procedures to reduce air in the circuit at the start of surgery, new methods for injecting drugs into the circuit during surgery, and better detection of removal of sources of air during surgery. The review concludes with background on the ultrasonic detection of GME, comparing through-transmission gross air detectors and Doppler ultrasound technology with fixed-beam ultrasonic imaging of emboli, a new ultrasonic technique that images moving emboli in the blood using a single ultrasound transducer element in a fixed position. This overview is meant to shed light on why different ultrasonic detection technologies report widely varying counts and emboli loads, and why fixed-beam ultrasonic imaging represents an improvement in the ability to monitor, measure and quantitate embolic load during CPB.


  • Gaseous Microemboli Sizing in Extracorporeal Circuits Using Ultrasound Backscatter

    by John E. Lynch, Alison Pouch, Randi Sanders, Mark Hinders, Kevin Rudd, John Sevick


  • Ultrasonic device for the noninvasive diagnosis of compartment syndrome

    by John E Lynch, Joseph S Heyman, Alan R Hargens

    An ultrasonic device for the diagnosis of acute compartment syndrome is described and results on six human cadaveric legs are presented. The ultrasonic device uses a pulsed phase locked loop (PPLL) to measure sub-micrometer displacements of the fascia wall. These displacements occur as a result of volume expansion of the muscle compartment of the lower leg and are related to changes in intramuscular pressure (IMP). In the cadaveric tests, the PPLL detected changes in compartment diameter resulting from IMP changes of 1 mmHg and from infusions of 0.25 ml saline increments. Based on these results, the ultrasonic PPLL appears to have the potential to become a low-cost, portable and noninvasive alternative to current methods for diagnosing acute compartment syndrome.