Shin Tsuge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shin Tsuge has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Ohtani
Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo‐cho, Chikusa‐ku, Nagoya 464‐8603, Japan
5 shared publications Chuichi Watanabe
Frontier Laboratories Ltd
2 shared publications- Yasuyuki Ishida
Department of Biological Chemistry, College of Bioscience and Biotechnology, Chubu University
2 shared publications - Akihiko Hosaka
Frontier Laboratories Ltd., 1-8-14, Saikon, Koriyama, Fukushima 963-8862, Japan
1 shared publication Hiroaki Yokoi
1 shared publicationKeishi Oba
Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Nagoya 464‐8603, Japan
1 shared publication
Latest Publications
- 1 January 2011
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 60 (3) , 239-244
Structural Characterization of Terminal-modified and Branched Polycarbonates by Pyrolysis-Gas Chromatography in the Presence of Organic Alkali
水酸化テトラメチルアンモニウム(TMAH)共存下での反応熱分解ガスクロマトグラフィー(反応Py-GC)により,末端変性又は分岐化により高性能化したビスフェノールA(BPA)ポリカーボネート(PC)の構造キャラクタリゼーションを行った.末端基を部分的にp-クミルフェノキシ(PCP)基に変性して耐衝撃性を向上したPCを,反応熱分解温度400℃で測定して得られたパイログラム上には,主成分であるBPA,変性されたPCP末端基,およびBPA型PCに一般的なp-tert-フェノキシ(PTBT)末端基をそれぞれ反映する,メチル誘導体のピークが定量的に観測された.ピーク強度から算出した末端基を含む構成成分組成ならびに数平均分子量は,NMRやサイズ排除クロマトグラフィー(SEC)などによる参照値ともほぼ一致した.一方,1,1,1-トリ(4-ヒドロキシフェニル)エタン(THPE)を共重合することにより分岐構造を導入して成形加工性を改善した,分岐化PC試料を同様に反応Py-GC測定して得られたパイログラム上には,BPA単位とPTBT末端基に加えて,THPE分岐単位を反映するメチル誘導体のピークが観測された.これらのピーク強度から算出した成分組成は,PTBP : BPA : THPE=3.7 : 95.8 : 0.5(mol%)であった.また,これらの結果を整理すると,一分子あたりの平均末端基数および平均分岐数はそれぞれ2.3及び0.33となった.これらをもとに計算した当該試料の数平均分子量は1.6×104であり,SEC測定による結果ともほぼ一致した.更に,平均分岐数から,当該分岐化PCについて,平均的には試料中の全分子の1/3が分子内に一つだけ分岐点を有し,残りの2/3は分岐を持たない直鎖状の分子であることが推定された.本法は,わずか50 μg程度の試料で,PCの化学構造を迅速にかつ定量的に解析することが可能である.また,測定の繰り返し再現性は,微量成分に対しても相対標準偏差5% 未満であり,定量精度も高いことが示された
- 1 January 2011
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 60 (3) , 239-244
Structural Characterization of Terminal-modified and Branched Polycarbonates by Pyrolysis-Gas Chromatography in the Presence of Organic Alkali
水酸化テトラメチルアンモニウム(TMAH)共存下での反応熱分解ガスクロマトグラフィー(反応Py-GC)により,末端変性又は分岐化により高性能化したビスフェノールA(BPA)ポリカーボネート(PC)の構造キャラクタリゼーションを行った.末端基を部分的にp-クミルフェノキシ(PCP)基に変性して耐衝撃性を向上したPCを,反応熱分解温度400℃で測定して得られたパイログラム上には,主成分であるBPA,変性されたPCP末端基,およびBPA型PCに一般的なp-tert-フェノキシ(PTBT)末端基をそれぞれ反映する,メチル誘導体のピークが定量的に観測された.ピーク強度から算出した末端基を含む構成成分組成ならびに数平均分子量は,NMRやサイズ排除クロマトグラフィー(SEC)などによる参照値ともほぼ一致した.一方,1,1,1-トリ(4-ヒドロキシフェニル)エタン(THPE)を共重合することにより分岐構造を導入して成形加工性を改善した,分岐化PC試料を同様に反応Py-GC測定して得られたパイログラム上には,BPA単位とPTBT末端基に加えて,THPE分岐単位を反映するメチル誘導体のピークが観測された.これらのピーク強度から算出した成分組成は,PTBP : BPA : THPE=3.7 : 95.8 : 0.5(mol%)であった.また,これらの結果を整理すると,一分子あたりの平均末端基数および平均分岐数はそれぞれ2.3及び0.33となった.これらをもとに計算した当該試料の数平均分子量は1.6×104であり,SEC測定による結果ともほぼ一致した.更に,平均分岐数から,当該分岐化PCについて,平均的には試料中の全分子の1/3が分子内に一つだけ分岐点を有し,残りの2/3は分岐を持たない直鎖状の分子であることが推定された.本法は,わずか50 μg程度の試料で,PCの化学構造を迅速にかつ定量的に解析することが可能である.また,測定の繰り返し再現性は,微量成分に対しても相対標準偏差5% 未満であり,定量精度も高いことが示された
- 3 July 2003
- Published by Wiley in Macromolecular Symposia
- Vol. 195 (1) , 287-292
Novel characterization of branching and/or cross-linking structures in condensation polymers by reactive pyrolysis-gas chromatography in the presence of organic alkaline
- 3 July 2003
- Published by Wiley in Macromolecular Symposia
- Vol. 195 (1) , 287-292
Novel characterization of branching and/or cross-linking structures in condensation polymers by reactive pyrolysis-gas chromatography in the presence of organic alkaline
- 1 January 1999
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 124 (5) , 669-674
Characterization of within-tree variation of lignin components in Eucalyptus camaldulensis by pyrolysis–gas chromatography
Pyrolysis–gas chromatography (Py-GC) using a vertical microfurnace pyrolyzer was applied to the precise determination of the ‘within-tree variation’ of the ratio of syringyl and guaiacyl units (S/G ratio) for lignin in Eucalyptus camaldulensis. On the pyrogram of the Eucalyptus obtained at 450 °C, many characteristic peaks derived from syringyl and guaiacyl units of lignin were reproducibly observed, together with those from cellulose and hemicellulose. On the basis of the relative intensities of those characteristic peaks relating to the syringyl and guaiacyl units, the ‘within-tree variation’ of the S/G ratio was determined precisely in about 1 h using only about 0.1 mg of the powdered wood sample with a 2% relative standard deviation. The results obtained were also compared with those obtained by the thioacidolysis method.
- 1 January 1999
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 124 (5) , 669-674
Characterization of within-tree variation of lignin components in Eucalyptus camaldulensis by pyrolysis–gas chromatography
Pyrolysis–gas chromatography (Py-GC) using a vertical microfurnace pyrolyzer was applied to the precise determination of the ‘within-tree variation’ of the ratio of syringyl and guaiacyl units (S/G ratio) for lignin in Eucalyptus camaldulensis. On the pyrogram of the Eucalyptus obtained at 450 °C, many characteristic peaks derived from syringyl and guaiacyl units of lignin were reproducibly observed, together with those from cellulose and hemicellulose. On the basis of the relative intensities of those characteristic peaks relating to the syringyl and guaiacyl units, the ‘within-tree variation’ of the S/G ratio was determined precisely in about 1 h using only about 0.1 mg of the powdered wood sample with a 2% relative standard deviation. The results obtained were also compared with those obtained by the thioacidolysis method.
- 1 January 1998
- Published by Springer Nature in Analytical Sciences
- Vol. 14 (2) , 431-434
Determination of Fortified Rosin-Glycerin Ester Sizing Agents in Paper by Reactive Pyrolysis-Gas Chromatography in the Presence of an Organic Alkali.
- 1 January 1998
- Published by Springer Nature in Analytical Sciences
- Vol. 14 (2) , 431-434
Determination of Fortified Rosin-Glycerin Ester Sizing Agents in Paper by Reactive Pyrolysis-Gas Chromatography in the Presence of an Organic Alkali.
- 1 January 1998
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 46 (4) , 332-335
Development of Selective Sampler on Evolved Gas Analysis Using Furnace Type Pyrolyzer.
- 1 January 1998
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 46 (4) , 332-335
Development of Selective Sampler on Evolved Gas Analysis Using Furnace Type Pyrolyzer.
- 1 January 1991
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 39 (1) , 43-47
Combination of capillary supercritical fluid chromatography and mass spectrometry with a vacuum nebulizing interface.
A combination system of capillary supercritical fluid chromatography (SFC) with a use of CO2 as a mobile phase and mass spectometry (MS) was developed by using a vacuum nebulizing interface. Application of the vacuum nebulizing interface enabled the operation of the SFC/MS system at a high pressure up to ca. 400 kg/cm2 attained by SFC pump. By adjusting the flow rate of the nebulizing gas, vacuum of the mass spectrometer was easily controlled for chemical ionization condition. In addition, the use of isobutane as a nebulizing gas enabled stable and continuous introduction of the sample into the ion source to attain soft ionization. Analytical conditions of this SFC/MS system were epitomized for caffeine as a test sample. The system was also applied to the analysis of polyethylene glycol-400.
- 1 January 1991
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 39 (1) , 43-47
Combination of capillary supercritical fluid chromatography and mass spectrometry with a vacuum nebulizing interface.
A combination system of capillary supercritical fluid chromatography (SFC) with a use of CO2 as a mobile phase and mass spectometry (MS) was developed by using a vacuum nebulizing interface. Application of the vacuum nebulizing interface enabled the operation of the SFC/MS system at a high pressure up to ca. 400 kg/cm2 attained by SFC pump. By adjusting the flow rate of the nebulizing gas, vacuum of the mass spectrometer was easily controlled for chemical ionization condition. In addition, the use of isobutane as a nebulizing gas enabled stable and continuous introduction of the sample into the ion source to attain soft ionization. Analytical conditions of this SFC/MS system were epitomized for caffeine as a test sample. The system was also applied to the analysis of polyethylene glycol-400.