CSCatalina Maria Sampol

Catalina Maria Sampol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Catalina Maria Sampol has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radioguided Surgery and Axillary Management in Breast Cancer: From Molecular Imaging to 3D Navigation Toward Personalized Treatment

    by John Orozco Cortés, Marta Tapia, Jorge Sabater Sancho, Carolina Castillo Arias, Elvira Buch Villa, Ernesto Muñoz Sornosa, Vicente Lopez Flor, Rafael Diaz Exposito, Luisa Fernanda Leon, Catalina Sampol Bas, et al.

    Radioguided surgery has become a key component of contemporary breast cancer care, supporting less invasive approaches while maintaining oncologic safety. This narrative review summarizes current practice and recent developments in radioguided breast and axillary surgery, from established molecular imaging workflows to emerging three-dimensional and intraoperative technologies. Modern breast cancer management is increasingly shaped by tumor biology and the widespread use of neoadjuvant systemic therapy, which is transforming surgical decision-making and driving a shift toward personalized, patient-tailored pathways. In this context, radioguided techniques help maintain procedural accuracy despite therapy-induced changes in breast and nodal anatomy, enabling reliable lesion localization and targeted management of the axilla. We discuss sentinel lymph node strategies and de-escalation concepts, including targeted axillary dissection (TAD) after neoadjuvant therapy using marked nodes and selective removal approaches. We also review localization methods, including radioactive seed–based techniques, and the expanding role of molecular imaging–guided surgery to support intraoperative decision-making. Particular attention is paid to technologies aimed at improving surgical precision and margin assessment, including portable/freehand SPECT concepts and intraoperative PET/CT-based specimen imaging for immediate evaluation of excised tissue. Finally, we highlight how artificial intelligence and digital tools may enable workflow optimization, navigation, image interpretation, and decision support, accelerating the transition toward individualized treatment. Overall, integrating molecular information with real-time 3D guidance can help tailor breast and axillary management to each patient while reducing morbidity.

  • Open Access

    Hybrid 99mTc–ICG Sentinel Lymph Node Mapping in Apparent Early-Stage Epithelial Ovarian Cancer: A First Prospective Evaluation of a True Molecular Hybrid Tracer (HibrOv Trial)

    by Joana Amengual Vila, Catalina Maria Sampol Bas, Adriana Quintero Duarte, Ane Ugarteburu Pérez, Mario Ruiz Coll, Jorge Rioja Merlo, Anna Torrent Colomer

    Background/Objectives: Systematic lymphadenectomy is recommended in apparent early-stage epithelial ovarian cancer (EOC) to assess nodal status, but it is associated with significant morbidity and lacks survival benefit. Sentinel lymph node (SLN) mapping may offer a less invasive alternative, although evidence remains limited due to the complexity of ovarian lymphatic drainage and methodological heterogeneity across studies. This prospective study evaluates the feasibility and diagnostic accuracy of a true hybrid 99mTc–indocyanine green (ICG) tracer for SLN mapping in apparent early-stage EOC. Methods: A prospective observational study was conducted at a tertiary oncology center between 2021 and 2026. Patients presenting with a suspicious ovarian mass (Group A) or requiring restaging after adnexectomy for confirmed EOC (Group B) underwent SLN mapping using a hybrid 99mTc–ICG tracer injected into the infundibulopelvic (IPL) and/or utero-ovarian ligament (UOL). SLNs were identified using gamma detection and near-infrared fluorescence imaging. All malignant cases underwent complete surgical staging including systematic pelvic and para-aortic lymphadenectomy. SLNs were ultrastaged and compared with the final nodal status. Results: Forty patients were included; 20 (50%) had malignant tumors. The overall SLN detection rate was 92.5% (37/40), with 100% in malignant cases. Among malignant tumors, 3/20 (15%) had metastatic SLNs, all accurately detected (false-negative rate 0%). Sensitivity and negative predictive value were 100%. Combined pelvic and para-aortic drainage was the most frequent pattern (75%). Conclusions: SLN mapping may represent a feasible and potentially accurate staging strategy in apparent early-stage EOC. In the present study, a hybrid 99mTc–ICG tracer was associated with high detection rates and complete concordance with final nodal status. These findings support further multicenter validation to define its potential role as an alternative to systematic lymphadenectomy.

  • Open Access

    Impact of lymph node staging techniques on lymphedema and quality of life in early-stage endometrial cancer: A prospective cohort study

    by Anna Torrent, Joana Amengual, Angela Ruiz, Aina Serra, Laura Fuertes, Catalina Maria Sampol, Mario Ruiz, Jorge Rioja, Pilar Roca, Octavi Cordoba


  • Open Access

    Detecting Atypical Sentinel Lymph Nodes in Early-Stage Cervical Cancer Using a Standardized Technique with a Hybrid Tracer

    by Joana Amengual Vila, Anna Torrent Colomer, Catalina Sampol Bas, Adriana Quintero Duarte, Mario Ruiz Coll, Jorge Rioja Merlo, Octavi Cordoba

    Background: Since October 2018, lymph node status has become part of the FIGO staging, given that it is one of the most important prognostic factors among women with CC. The aim was to determine the rate of atypical lymphatic drainage in patients with clinical early-stage cervical cancer using a hybrid tracer (ICG-99mTc nanocolloid). Methodology: A prospective, observational, single-centre study conducted at Son Espases University Hospital between January 2019 and October 2023. Patients with clinical early-stage CC who underwent SLN mapping were included. External iliac and obturator nodes were defined as common locations. Para-aortic, common iliac, presacral, internal iliac, and parametrial nodes were defined as atypical locations. Results: Thirty-nine cases of CC were included. The overall SLN detection rate was 97.4%, with 89.5% bilaterally. Positive nodes were found in 21.1% of patients. Atypical lymphatic drainage was present in 8 out of 38 (21.1%) patients. Of all the SLNs biopsied (146), 10.3% corresponded to an atypical zone. SLN in the atypical area had a higher proportion of metastasis than the usual area (37.5% vs. 16.7%; p = 0.327). Conclusions: SLN biopsy can detect unusual drainage in a significant proportion of patients. Atypical lymph nodes have a higher percentage of metastasis, which consequently improves staging and tailoring therapy. SLN mapping performed via a standardized surgical technique using a hybrid tracer (ICG-99mTc) could help in the identification of the “true SLN”.


  • Open Access

    Sentinel Lymph Node Biopsy in Endometrial Cancer: Dual Injection, Dual Tracer—A Multidisciplinary Exhaustive Approach to Nodal Staging

    by Anna Torrent, Joana Amengual, Catalina Maria Sampol, Mario Ruiz, Jorge Rioja, Gabriel Matheu, Pilar Roca, Octavi Cordoba

    Introduction: Sentinel lymph node (SLN) has recently been introduced as a standard staging technique in endometrial cancer (EC). There are some issues regarding team experience and para-aortic detection. Objective: to report the accuracy of SLN detection in EC with a dual tracer (ICG and Tc99) and dual injection site (cervix and fundus) during the learning curve. Methods: A prospective, observational single-center trial including 48 patients diagnosed with early-stage EC. Dual intracervical tracer (Tc99 and ICG) was injected at different times. High-risk patients had a second fundus injection with both tracers. Results: the detection rates were as follows: 100% (48/48) overall for SLNs; 98% (47/48) overall for pelvic SLNs; 89.5% (43/48) for bilateral SLNs; and 2% (1/48) for isolated para-aortic SLNs. In high-risk patients, the para-aortic overall DR was 66.7% (22/33); 60.7% (17/28) with ICG and 51.5% (17/33) with Tc99 (p = 0.048)). Overall rate of lymph node involvement was 14.6% (7/48). Macroscopic pelvic metastasis was found in four patients (8.3%) and microscopic in one case (2%). No metastasis was found in any para-aortic SLNs. Half of the patients with positive pelvic SLNs had positive para-aortic nodes. In high-risk patients, when para-aortic SLNs mapped failed, 36.4% (4/11) had positive nodes in para-aortic lymphadenectomy. The sensitivity and negative predictive value (NPV) of SLN pelvic detection was 100%. Conclusions: Multidisciplinary exhaustive approach gives a suitable accuracy of SLN during learning curve. Dual injection (cervical and fundal) with dual tracer (ICG and Tc99) offers good overall detection rates and increases para-aortic SLN detection.


  • Axillary recurrences after sentinel lymph node biopsy in initial breast cancer

    by C. Sampol, M. Giménez, J. Torrecabota, C. Serra, R. Canet, J. Daumal, C. Peña, L. Gonzalez, E. Hernandez, A. Graner, et al.

  • Análisis de recurrencias axilares tras biopsia selectiva del ganglio centinela en cáncer de mama inicial

    by C. Sampol, M. Giménez, J. Torrecabota, C. Serra, R. Canet, J. Daumal, C. Peña, L. Gonzalez, E. Hernandez, A. Graner, et al.