Anna Torrent Colomer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Torrent Colomer has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Catalina Maria Sampol
Department of Nuclear Medicine, Hospital Universitari Son Espases, 07120 Palma, Spain
4 shared publications - Joana Amengual
Gynecologic Oncology Unit, Obstetrics and Gynecology Department, Hospital Universitari Son Espases, 07120 Palma, Spain
4 shared publications - Jorge Rioja Merlo
Gynecologic Oncology Unit, Obstetrics and Gynecology Department, Hospital Universitari Son Espases, 07120 Palma, Spain
4 shared publications - Mario Ruiz Coll
Gynecologic Oncology Unit, Obstetrics and Gynecology Department, Hospital Universitari Son Espases, 07120 Palma, Spain
4 shared publications - Octavi Córdoba
Gynecologic Oncology Unit, Obstetrics and Gynecology Department, Hospital Universitari Son Espases, 07120 Palma, Spain
3 shared publications - Adriana Quintero Duarte
Department of Pathology, Hospital Universitari Son Espases, 07120 Palma, Spain
2 shared publications
Latest Publications
- Open Access
Hybrid 99mTc–ICG Sentinel Lymph Node Mapping in Apparent Early-Stage Epithelial Ovarian Cancer: A First Prospective Evaluation of a True Molecular Hybrid Tracer (HibrOv Trial)
Background/Objectives: Systematic lymphadenectomy is recommended in apparent early-stage epithelial ovarian cancer (EOC) to assess nodal status, but it is associated with significant morbidity and lacks survival benefit. Sentinel lymph node (SLN) mapping may offer a less invasive alternative, although evidence remains limited due to the complexity of ovarian lymphatic drainage and methodological heterogeneity across studies. This prospective study evaluates the feasibility and diagnostic accuracy of a true hybrid 99mTc–indocyanine green (ICG) tracer for SLN mapping in apparent early-stage EOC. Methods: A prospective observational study was conducted at a tertiary oncology center between 2021 and 2026. Patients presenting with a suspicious ovarian mass (Group A) or requiring restaging after adnexectomy for confirmed EOC (Group B) underwent SLN mapping using a hybrid 99mTc–ICG tracer injected into the infundibulopelvic (IPL) and/or utero-ovarian ligament (UOL). SLNs were identified using gamma detection and near-infrared fluorescence imaging. All malignant cases underwent complete surgical staging including systematic pelvic and para-aortic lymphadenectomy. SLNs were ultrastaged and compared with the final nodal status. Results: Forty patients were included; 20 (50%) had malignant tumors. The overall SLN detection rate was 92.5% (37/40), with 100% in malignant cases. Among malignant tumors, 3/20 (15%) had metastatic SLNs, all accurately detected (false-negative rate 0%). Sensitivity and negative predictive value were 100%. Combined pelvic and para-aortic drainage was the most frequent pattern (75%). Conclusions: SLN mapping may represent a feasible and potentially accurate staging strategy in apparent early-stage EOC. In the present study, a hybrid 99mTc–ICG tracer was associated with high detection rates and complete concordance with final nodal status. These findings support further multicenter validation to define its potential role as an alternative to systematic lymphadenectomy.
Open AccessHybrid 99mTc–ICG Sentinel Lymph Node Mapping in Apparent Early-Stage Epithelial Ovarian Cancer: A First Prospective Evaluation of a True Molecular Hybrid Tracer (HibrOv Trial)
Background/Objectives: Systematic lymphadenectomy is recommended in apparent early-stage epithelial ovarian cancer (EOC) to assess nodal status, but it is associated with significant morbidity and lacks survival benefit. Sentinel lymph node (SLN) mapping may offer a less invasive alternative, although evidence remains limited due to the complexity of ovarian lymphatic drainage and methodological heterogeneity across studies. This prospective study evaluates the feasibility and diagnostic accuracy of a true hybrid 99mTc–indocyanine green (ICG) tracer for SLN mapping in apparent early-stage EOC. Methods: A prospective observational study was conducted at a tertiary oncology center between 2021 and 2026. Patients presenting with a suspicious ovarian mass (Group A) or requiring restaging after adnexectomy for confirmed EOC (Group B) underwent SLN mapping using a hybrid 99mTc–ICG tracer injected into the infundibulopelvic (IPL) and/or utero-ovarian ligament (UOL). SLNs were identified using gamma detection and near-infrared fluorescence imaging. All malignant cases underwent complete surgical staging including systematic pelvic and para-aortic lymphadenectomy. SLNs were ultrastaged and compared with the final nodal status. Results: Forty patients were included; 20 (50%) had malignant tumors. The overall SLN detection rate was 92.5% (37/40), with 100% in malignant cases. Among malignant tumors, 3/20 (15%) had metastatic SLNs, all accurately detected (false-negative rate 0%). Sensitivity and negative predictive value were 100%. Combined pelvic and para-aortic drainage was the most frequent pattern (75%). Conclusions: SLN mapping may represent a feasible and potentially accurate staging strategy in apparent early-stage EOC. In the present study, a hybrid 99mTc–ICG tracer was associated with high detection rates and complete concordance with final nodal status. These findings support further multicenter validation to define its potential role as an alternative to systematic lymphadenectomy.
- Open Access
- 4 August 2025
- Published by Elsevier in Gynecologic Oncology Reports
- Vol. 60, 101919
Impact of lymph node staging techniques on lymphedema and quality of life in early-stage endometrial cancer: A prospective cohort study
- 4 August 2025
- Published by Elsevier in Gynecologic Oncology Reports
- Vol. 60, 101919
Open AccessImpact of lymph node staging techniques on lymphedema and quality of life in early-stage endometrial cancer: A prospective cohort study
- Open Access
Detecting Atypical Sentinel Lymph Nodes in Early-Stage Cervical Cancer Using a Standardized Technique with a Hybrid Tracer
Background: Since October 2018, lymph node status has become part of the FIGO staging, given that it is one of the most important prognostic factors among women with CC. The aim was to determine the rate of atypical lymphatic drainage in patients with clinical early-stage cervical cancer using a hybrid tracer (ICG-99mTc nanocolloid). Methodology: A prospective, observational, single-centre study conducted at Son Espases University Hospital between January 2019 and October 2023. Patients with clinical early-stage CC who underwent SLN mapping were included. External iliac and obturator nodes were defined as common locations. Para-aortic, common iliac, presacral, internal iliac, and parametrial nodes were defined as atypical locations. Results: Thirty-nine cases of CC were included. The overall SLN detection rate was 97.4%, with 89.5% bilaterally. Positive nodes were found in 21.1% of patients. Atypical lymphatic drainage was present in 8 out of 38 (21.1%) patients. Of all the SLNs biopsied (146), 10.3% corresponded to an atypical zone. SLN in the atypical area had a higher proportion of metastasis than the usual area (37.5% vs. 16.7%; p = 0.327). Conclusions: SLN biopsy can detect unusual drainage in a significant proportion of patients. Atypical lymph nodes have a higher percentage of metastasis, which consequently improves staging and tailoring therapy. SLN mapping performed via a standardized surgical technique using a hybrid tracer (ICG-99mTc) could help in the identification of the “true SLN”.
Open AccessDetecting Atypical Sentinel Lymph Nodes in Early-Stage Cervical Cancer Using a Standardized Technique with a Hybrid Tracer
Background: Since October 2018, lymph node status has become part of the FIGO staging, given that it is one of the most important prognostic factors among women with CC. The aim was to determine the rate of atypical lymphatic drainage in patients with clinical early-stage cervical cancer using a hybrid tracer (ICG-99mTc nanocolloid). Methodology: A prospective, observational, single-centre study conducted at Son Espases University Hospital between January 2019 and October 2023. Patients with clinical early-stage CC who underwent SLN mapping were included. External iliac and obturator nodes were defined as common locations. Para-aortic, common iliac, presacral, internal iliac, and parametrial nodes were defined as atypical locations. Results: Thirty-nine cases of CC were included. The overall SLN detection rate was 97.4%, with 89.5% bilaterally. Positive nodes were found in 21.1% of patients. Atypical lymphatic drainage was present in 8 out of 38 (21.1%) patients. Of all the SLNs biopsied (146), 10.3% corresponded to an atypical zone. SLN in the atypical area had a higher proportion of metastasis than the usual area (37.5% vs. 16.7%; p = 0.327). Conclusions: SLN biopsy can detect unusual drainage in a significant proportion of patients. Atypical lymph nodes have a higher percentage of metastasis, which consequently improves staging and tailoring therapy. SLN mapping performed via a standardized surgical technique using a hybrid tracer (ICG-99mTc) could help in the identification of the “true SLN”.
- Open Access
Sentinel Lymph Node Biopsy in Endometrial Cancer: Dual Injection, Dual Tracer—A Multidisciplinary Exhaustive Approach to Nodal Staging
Introduction: Sentinel lymph node (SLN) has recently been introduced as a standard staging technique in endometrial cancer (EC). There are some issues regarding team experience and para-aortic detection. Objective: to report the accuracy of SLN detection in EC with a dual tracer (ICG and Tc99) and dual injection site (cervix and fundus) during the learning curve. Methods: A prospective, observational single-center trial including 48 patients diagnosed with early-stage EC. Dual intracervical tracer (Tc99 and ICG) was injected at different times. High-risk patients had a second fundus injection with both tracers. Results: the detection rates were as follows: 100% (48/48) overall for SLNs; 98% (47/48) overall for pelvic SLNs; 89.5% (43/48) for bilateral SLNs; and 2% (1/48) for isolated para-aortic SLNs. In high-risk patients, the para-aortic overall DR was 66.7% (22/33); 60.7% (17/28) with ICG and 51.5% (17/33) with Tc99 (p = 0.048)). Overall rate of lymph node involvement was 14.6% (7/48). Macroscopic pelvic metastasis was found in four patients (8.3%) and microscopic in one case (2%). No metastasis was found in any para-aortic SLNs. Half of the patients with positive pelvic SLNs had positive para-aortic nodes. In high-risk patients, when para-aortic SLNs mapped failed, 36.4% (4/11) had positive nodes in para-aortic lymphadenectomy. The sensitivity and negative predictive value (NPV) of SLN pelvic detection was 100%. Conclusions: Multidisciplinary exhaustive approach gives a suitable accuracy of SLN during learning curve. Dual injection (cervical and fundal) with dual tracer (ICG and Tc99) offers good overall detection rates and increases para-aortic SLN detection.
Open AccessSentinel Lymph Node Biopsy in Endometrial Cancer: Dual Injection, Dual Tracer—A Multidisciplinary Exhaustive Approach to Nodal Staging
Introduction: Sentinel lymph node (SLN) has recently been introduced as a standard staging technique in endometrial cancer (EC). There are some issues regarding team experience and para-aortic detection. Objective: to report the accuracy of SLN detection in EC with a dual tracer (ICG and Tc99) and dual injection site (cervix and fundus) during the learning curve. Methods: A prospective, observational single-center trial including 48 patients diagnosed with early-stage EC. Dual intracervical tracer (Tc99 and ICG) was injected at different times. High-risk patients had a second fundus injection with both tracers. Results: the detection rates were as follows: 100% (48/48) overall for SLNs; 98% (47/48) overall for pelvic SLNs; 89.5% (43/48) for bilateral SLNs; and 2% (1/48) for isolated para-aortic SLNs. In high-risk patients, the para-aortic overall DR was 66.7% (22/33); 60.7% (17/28) with ICG and 51.5% (17/33) with Tc99 (p = 0.048)). Overall rate of lymph node involvement was 14.6% (7/48). Macroscopic pelvic metastasis was found in four patients (8.3%) and microscopic in one case (2%). No metastasis was found in any para-aortic SLNs. Half of the patients with positive pelvic SLNs had positive para-aortic nodes. In high-risk patients, when para-aortic SLNs mapped failed, 36.4% (4/11) had positive nodes in para-aortic lymphadenectomy. The sensitivity and negative predictive value (NPV) of SLN pelvic detection was 100%. Conclusions: Multidisciplinary exhaustive approach gives a suitable accuracy of SLN during learning curve. Dual injection (cervical and fundal) with dual tracer (ICG and Tc99) offers good overall detection rates and increases para-aortic SLN detection.