PHPedro Hinarejos

Pedro Hinarejos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pedro Hinarejos has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Popliteal artery entrapment syndrome. Current concepts, dilemmas, and challenges

    by Laura Calsina-Juscafresa, Albert Clarà, Pedro Hinarejos, Oscar Gasulla, Salvatore Marsico, Joan Carles Monllau

    Introduction: Popliteal artery entrapment syndrome (PAES) results from extrinsic compression of the popliteal artery as it passes through the popliteal fossa due to congenital musculotendinous anomalies or acquired muscle hypertrophy. The consequence of this compression is a progressive damage to the arterial wall, which can ultimately cause irreversible injury. This damage initially manifests as intermittent claudication, which usually occurs in young, athletic individuals with no cardiovascular risk factors. There may be an overlap of symptoms with other conditions, making diagnosis challenging. Beyond clinical suspicion, dynamic tests with provocation manoeuvres are essential. Early decompression treatment of symptomatic cases can prevent the onset of potentially serious complications, including amputation. Sources of data: This review integrates evidence from peer-reviewed literature focusing on popliteal entrapment syndrome. Areas of agreement: Shortening the timeline from diagnosis to referral can help prevent irreversible damage to the arteries. There are a significant number of publications on PAES, based on retrospective single-centre experiences, short series or case reports, and limited scientific evidence. All publications repeatedly conclude that prospective multicentre studies are needed to standardize diagnostic and therapeutic protocols and develop guidelines for PAES. Areas of controversy: There are many points of disagreement regarding the management of PAES, and this does not help in addressing two key issues: avoiding misdiagnosis and unnecessary surgeries, which promote delayed diagnosis in worse clinical conditions. Growing points: The creation of multicentre working groups seems necessary due to the limited number of cases at individual centres for conducting prospective studies. Areas timely for developing research: Creation of international consensus protocols on definition, diagnosis, and treatment of PAES.

  • Open Access

    Mechanical axis correction after total knee arthroplasty alters ankle alignment but does not affect ankle function

    by Alba Portes‐Chiva, Ana Soria‐Blázquez, Pedro Hinarejos, Raul Torres‐Claramunt, Simone Perelli, Juan‐Francisco Sánchez‐Soler, Alberto Ginés‐Cespedosa, Juan‐Carlos Monllau

    Purpose: Total knee arthroplasty (TKA) restores knee function, but correction of coronal plane deformities may alter the biomechanics of adjacent joints. This study aimed to determine whether changes in knee alignment after TKA have clinical or radiological effects on the ankle. Methods: A prospective observational study included 158 patients undergoing TKA, of whom 128 completed 1‐year follow‐up. Clinical outcomes were assessed preoperatively and at 3, 6 and 12 months using the Manchester‐Oxford Foot Questionnaire (MOXFQ), Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), European Quality of Life (EuroQol) and Forgotten Joint Score‐12 (FJS‐12). Radiographic parameters, including the mechanical axis of the limb and the ankle joint orientation angle (AJOA), were measured preoperatively and at 6 months postoperatively. Results: The mean mechanical axis improved from 5.8° varus to 1.3° varus ( p < 0.001). The AJOA changed from −0.8° to 0.8° ( p = 0.001). A moderate positive correlation was found between the change in AJOA and the degree of knee axis correction (rho = 0.4, p < 0.001). No significant correlation was found between mechanical axis correction and MOXFQ scores at 3, 6 or 12 months. All patient‐reported outcome measures improved after surgery compared with preoperative values. Conclusions: Correction of the mechanical axis following TKA modifies ankle radiographic alignment but does not significantly affect ankle function at 1 year in patients with moderate deformities. Functional outcomes improved after surgery regardless of the degree of alignment change. Level of Evidence: Level II.

  • Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique

    by Oriol Pujol, Pedro Hinarejos, Albert Pons, Ernest Famada, Angela Zumel, Matías Novillo, Juan Erquicia, Joan Leal‐Blanquet

    Purpose: (1) To analyse the femoral anatomical–mechanical axis (AA–MA) and posterior condylar–transepicondylar axis (PCA–TEA) relationships using computed tomography (CT)‐based measurements. (2) To quantify the coronal and axial errors that would occur when positioning the femoral component using mechanically aligned TKA modelled as 5° of valgus from the AA and 3° of external rotation from the PCA. (3) To compare coronal and rotational femoral positioning between this systematic approach and robotic‐assisted functionally aligned TKA. Methods: It is a multicentric cross‐sectional observational study. Preoperative CT scans of 318 patients were analysed to determine AA–MA and PCA–TEA relationships. Then, femoral positioning was simulated, intending a measured‐resection mechanical aligned TKA defined as 5° of valgus from the AA and 3° of external rotation from the PCA. It was compared with the real femoral component placement performed in each patient using robotic‐assisted functionally aligned TKA. Results: Mean AA–MA relationship was 6.0 ± 0.9° and mean PCA–TEA was 3.1 ± 1.8°. In measured‐resection, mechanically aligned TKA, 74.4% and 45.8% of patients would present a femoral component implanted in varus from the MA and internal rotation from the TEA, respectively. Functional alignment was significantly closer to the native LDFA than mechanical alignment (2.0° vs 3.5°). With mechanical alignment, 45.8% of femoral components would be implanted in internal rotation from the TEA, compared to only 8.8% with functional alignment. Conclusions: Measured resection based on average population data (5° of valgus from the AA and 3° of external rotation from the PCA) may result in a considerable proportion of femoral components implanted in varus and internal rotation. In contrast, robotic‐assisted functionally aligned TKA provided significantly improved restoration of the native femoral joint line obliquity and effectively prevented excessive internal rotation. Level of Evidence: Level IV.


  • Poor side‐to‐side symmetry limits the use of the contralateral limb as a reliable reference for guiding coronal positioning and alignment in total knee arthroplasty

    by Oriol Pujol, Pedro Hinarejos, Albert Pons, Ernest Famada, Angela Zumel, Juan Erquicia, Joan Leal‐Blanquet

    Purpose: To assess the symmetry of coronal alignment in the lower limbs of patients with knee osteoarthritis to evaluate whether the contralateral lower limb can serve as a reliable reference for guiding coronal positioning and alignment in total knee arthroplasty (TKA) surgery.Methods: This is a multicentric cross‐sectional observational study. Preoperative full‐leg weight‐bearing radiographies from patients with knee osteoarthritis treated with a TKA between 2022 and 2024 were analyzed. Radiological parameters were measured in both lower limbs: medial proximal tibial angle, tibial mechanical angle (TMA), lateral distal femoral angle, femoral mechanical angle (FMA), hip–knee–ankle angle (HKA) and Kellgren–Lawrence. Lower limb coronal symmetry was assessed using the HKA, coronal plane alignment of the knee (CPAK) and phenotypes classifications. The relationship between concordance rates and osteoarthritis severity and symmetry was also analyzed.Results: Seventy‐six patients were included. The operated‐to‐contralateral concordance for the HKA classification was 57%. It was higher when the operated knee was neutral (81%), compared to varus (58%) or valgus (27%). The CPAK concordance was 38%; it was similar across different CPAK types. The phenotype classification concordance was only 11%; 30% for the HKA parameter, 39% for FMA and 34% for TMA. There was no relationship between osteoarthritis severity or symmetry and coronal concordance rates.Conclusions: Patients with knee osteoarthritis have poor side‐to‐side symmetry in lower limb coronal alignment. The concordance rate was 56% for the HKA classification, 39% for the CPAK classification and 11% for the phenotype classification. Therefore, the contralateral lower limb may not be a reliable reference for guiding coronal positioning and alignment in TKA surgery.Level of Evidence: Level III.


  • Open Access

    Bone Cut Accuracy in Total Knee Arthroplasty: Do Conventional Cutting Guides Stay True to the Planned Coronal Orientation of the Components?

    by Joan Leal-Blanquet, Pedro Hinarejos, Elisenda Gimenez-Valero, Raul Torres-Claramunt, Juan Sánchez-Soler, Juan Erquicia, Sergi Gil-González, Angela Zumel-Marne, Juan Carlos Monllau

    Background: Total knee arthroplasty (TKA) has become the gold standard for the definitive treatment of knee osteoarthritis. One crucial aspect in the implantation of a TKA is the precise orientation of the femoral and tibial components. The main purpose of the present study is to assess, in patients undergoing total knee replacement, whether the difference between the planned angulation in the distal femoral cut and the angulation obtained in the postoperative radiological control is low enough to consider the conventional bone-cutting guides reliable. Methods: A retrospective study was designed with a consecutive series of patients who had undergone primary total knee arthroplasty using conventional instrumentation over one year. The authors analysed the main variable (bone cuts) while considering different variables (age, gender, surgeon, prosthesis, laterality, constraint, body mass index and alignment) to identify different patient patterns that justify the results in the main variable. Descriptive variables were analysed using the Mann–Whitney U and Kruskal–Wallis tests. Additionally, the correlation between continuous variables was explored in accordance with the Spearman correlation. Results: A total of 340 patients with a mean age of 75 ± 9.16 years were finally included in the present study. The mean absolute error of the main variable for the femoral coronal bone cut was 1.89° (SD 1.53). For the tibial coronal bone cut, it was 1.31° (SD 2.54). These values correspond to what remains after subtracting the radiological angulation obtained in the postoperative period from the planned intraoperative angulation of the distal femoral cut. No associations were observed between the main variable (the angulation of the proximal tibial cut and distal femoral cut) and the rest of variables for either the femur or tibia. Conclusion: A discrepancy between the planned angulation and the final radiological measure on the coronal plane of the femur and tibia using conventional cutting guides has been demonstrated. The degree of deviation is low enough that it probably does not affect clinical outcomes. Therefore, the use of conventional cutting guides will continue to be an appropriate tool to perform bone cuts in knee replacement surgery.


  • Increased posterior translation but similar clinical outcomes using ultracongruent instead of posterior stabilized total knee arthroplasties in a prospective randomized trial

    by Pedro Hinarejos, Joan Leal‐Blanquet, Anna Fraile‐Suari, Juan Sánchez‐Soler, Raul Torres‐Claramunt, Juan Carlos Monllau

    Purpose: The aim of this study was to compare the posterior tibial translation after ultracongruent (UC) and posterior‐stabilized (PS) total knee arthroplasty (TKA) with two different UC with different heights in the anterior lip, and two different PS designs. This study also aimed to compare the range of motion (ROM) and outcomes scores after the use of these TKA models. It was hypothesised less posterior tibial translation after PS than after UC TKA, and less posterior tibial translation with a higher anterior lip in the UC insert than with a lower one.Methods: It was designed as a prospective randomized study of a group of 120 patients operated with a cemented TKA. To clarify the main purpose of the study, four groups were analysed using different polyethylene designs: Triathlon PS insert in group one, Triathlon UC insert in group two, U2 PS insert in group three and U2 UC insert in group four. One year after surgery, a forced posterior drawer with a Telos Stress applying 15 kg of force posteriorly on the proximal tibia at 90° of knee flexion was analysed in the lateral radiograph. Limb alignment, tibial posterior slope and posterior condylar offset were also studied.Results: 30 patients were included in each group. The average age was 73 years. There were 72.2% female and 27.8% male patients. There were no significant differences in any demographic or radiographic studied variables, preoperative range of motion (ROM) or preoperative Knee Society Scores (KSS) among the different groups. One year after surgery, the average postoperative ROM and the postoperative KSS Knee and KSS Function scores improved in respect of the preoperative values in all the groups. There were no significant differences in the postoperative outcome scores among the different groups (p = n.s.). Postoperative alignment of the limb, tibial posterior slope and posterior condylar offset were similar in the 4 study groups (p = n.s.). The postoperative posterior tibial translation was different between groups: the PS groups (groups 1 and 3) showed significant inferior values (p < 0.001) in respect of the UC groups (groups 2 and 4). There were no differences between both groups of PS models, but there was a significant increase in the posterior tibial translation of the Triathlon UC insert (11.2 mm SD 3.2) in respect of the U2 UC insert (6.1 mm SD 4.5) (p = 0.004).Conclusions: UC inserts restrict the posterior tibial translation after TKA less than PS inserts, but a design with a high anterior lip in the polyethylene UC insert can better control the posterior tibial translation than an insert with a small anterior lip.Level of evidence: Level I. Randomised controlled trial.


  • The technique of cement application has no influence on cement intrusion in total knee arthroplasty: randomized study comparing three different techniques

    by Pedro Hinarejos, Albert Fontanellas, Joan Leal‐Blanquet, Juan Sánchez‐Soler, Raul Torres‐Claramunt, Juan Carlos Monllau

    Purpose: The aim of the study was to compare the distance of intrusion of the cement into the bone in different areas both in the femur and the tibia in vivo, measured in the radiograph after implanting a total knee arthroplasty (TKA) with three different cement techniques.Methods: A prospective randomized study of 90 consecutive patients operated on at our institution with a cemented U2 Knee System TKA and medium viscosity Simplex P® bone cement. After pulse lavage, the cement was applied on the bone surfaces (group 1), on the implant surfaces (group 2) or both on the bone and the implant surfaces (group 3). The cement intrusion was measured in the postoperative radiographs in eight different regions in the tibial component and in six regions in the femoral component. The cement employed was calculated by weighting the cement after mixing and weighting the discarded cement.Results: The average intrusion of the cement was similar in all three groups of cementing techniques in the femoral components (1.6 mm; p = 0.386), and in the tibial components (2.6 mm; p = 0.144). The intrusion of the cement in the tibia was greater in women than in men (p = 0.04). We used 21.1 (SD 5.8) g of cement in average. The amount of cement employed was greater when the cement was applied on both (implant and bone) surfaces (group 3: 24.03 g in average) than when it was applied only on the bone (group 1: 20.13 g; p = 0.01) or only on the implants (group 2: 19.20 g; p = 0.001). The amount of cement employed was greater in men than in women (p = 0.002) and it was also greater when a PS femoral component was used (p = 0.03). The amount of cement employed was directly correlated with the height of the patients (p = 0.01) and with the bigger size of the components (p < 0.001).Conclusion: All three cement application techniques have similar intrusion distance of the cement into the bone, and the intrusion depth of the cement into the trabecular tibial bone is greater than the minimum suggested for fixation.