JEJuan Erquicia

Juan Erquicia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan Erquicia has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robotic quantification of the mechanical effect of corrective manoeuvres for intraoperative extension deficiency in total knee arthroplasty: A cadaveric study

    by Albert Pons‐Riverola, Juan Ignacio Erquicia, Eric Camprubí, Berta Gasol, Ángela Zumel, Santiago Bonduel, Joan Leal‐Blanquet

    Purpose: Intraoperative extension deficiency (IED) may arise after trial component implantation during total knee arthroplasty (TKA), a condition conceptually distinct from preoperative fixed flexion contracture (FFC). This study utilised a robotic system to quantify the incremental mechanical effect of sequential surgical actions—posterior capsule release (PCR), posterior cruciate ligament (PCL) excision and incremental distal femoral resections—to correct IED. A secondary objective was to evaluate their impact on manually assessed mediolateral laxity. Methods: Twenty‐nine robotic TKAs were performed on 15 fresh‐frozen cadaveric specimens. Nineteen knees presented with IED. All knees underwent PCR as the initial corrective manoeuvre. Subsequently, a quasi‐experimental design based on laterality was employed to evaluate two sequences: right knees underwent PCL excision followed by up to four 1‐mm distal femoral recuts; left knees followed the reverse order. Extension gains and manually assessed mediolateral laxities were recorded after each step. Results: Baseline IED averaged 6.6° ± 4.9°. Posterior capsule release corrected IED in 36.8% of the knees, yielding a mean extension gain of 1.68° ± 1.11°. The mechanical impact of distal femoral resections varied depending on PCL status: when the PCL remained intact, distal femoral recuts produced a substantial mean gain of 4.3° ± 0.6° per millimetre; however, following PCL excision, the gain per millimetre decreased to 2.8° ± 0.8°. PCL excision alone improved extension by a mean of 1.1° ± 1.3°. No significant changes in manually assessed mediolateral laxity at 0° and 90° of flexion were observed across manoeuvres. Conclusions: Robotic quantification demonstrates that the mechanical effectiveness of distal femoral resection is significantly enhanced by an intact PCL. While PCR is an impactful initial step for mild IED, distal femoral recuts provide greater extension gains. These objective data provide the foundation for a structured strategy to guide the intraoperative management of IED in both robotic and conventional TKA. Level of Evidence: N/A (cadaveric).


  • Functional alignment improves femoral joint line obliquity preservation in comparison with the classical measured resection technique

    by Oriol Pujol, Pedro Hinarejos, Albert Pons, Ernest Famada, Angela Zumel, Matías Novillo, Juan Erquicia, Joan Leal‐Blanquet

    Purpose: (1) To analyse the femoral anatomical–mechanical axis (AA–MA) and posterior condylar–transepicondylar axis (PCA–TEA) relationships using computed tomography (CT)‐based measurements. (2) To quantify the coronal and axial errors that would occur when positioning the femoral component using mechanically aligned TKA modelled as 5° of valgus from the AA and 3° of external rotation from the PCA. (3) To compare coronal and rotational femoral positioning between this systematic approach and robotic‐assisted functionally aligned TKA. Methods: It is a multicentric cross‐sectional observational study. Preoperative CT scans of 318 patients were analysed to determine AA–MA and PCA–TEA relationships. Then, femoral positioning was simulated, intending a measured‐resection mechanical aligned TKA defined as 5° of valgus from the AA and 3° of external rotation from the PCA. It was compared with the real femoral component placement performed in each patient using robotic‐assisted functionally aligned TKA. Results: Mean AA–MA relationship was 6.0 ± 0.9° and mean PCA–TEA was 3.1 ± 1.8°. In measured‐resection, mechanically aligned TKA, 74.4% and 45.8% of patients would present a femoral component implanted in varus from the MA and internal rotation from the TEA, respectively. Functional alignment was significantly closer to the native LDFA than mechanical alignment (2.0° vs 3.5°). With mechanical alignment, 45.8% of femoral components would be implanted in internal rotation from the TEA, compared to only 8.8% with functional alignment. Conclusions: Measured resection based on average population data (5° of valgus from the AA and 3° of external rotation from the PCA) may result in a considerable proportion of femoral components implanted in varus and internal rotation. In contrast, robotic‐assisted functionally aligned TKA provided significantly improved restoration of the native femoral joint line obliquity and effectively prevented excessive internal rotation. Level of Evidence: Level IV.


  • Poor side‐to‐side symmetry limits the use of the contralateral limb as a reliable reference for guiding coronal positioning and alignment in total knee arthroplasty

    by Oriol Pujol, Pedro Hinarejos, Albert Pons, Ernest Famada, Angela Zumel, Juan Erquicia, Joan Leal‐Blanquet

    Purpose: To assess the symmetry of coronal alignment in the lower limbs of patients with knee osteoarthritis to evaluate whether the contralateral lower limb can serve as a reliable reference for guiding coronal positioning and alignment in total knee arthroplasty (TKA) surgery.Methods: This is a multicentric cross‐sectional observational study. Preoperative full‐leg weight‐bearing radiographies from patients with knee osteoarthritis treated with a TKA between 2022 and 2024 were analyzed. Radiological parameters were measured in both lower limbs: medial proximal tibial angle, tibial mechanical angle (TMA), lateral distal femoral angle, femoral mechanical angle (FMA), hip–knee–ankle angle (HKA) and Kellgren–Lawrence. Lower limb coronal symmetry was assessed using the HKA, coronal plane alignment of the knee (CPAK) and phenotypes classifications. The relationship between concordance rates and osteoarthritis severity and symmetry was also analyzed.Results: Seventy‐six patients were included. The operated‐to‐contralateral concordance for the HKA classification was 57%. It was higher when the operated knee was neutral (81%), compared to varus (58%) or valgus (27%). The CPAK concordance was 38%; it was similar across different CPAK types. The phenotype classification concordance was only 11%; 30% for the HKA parameter, 39% for FMA and 34% for TMA. There was no relationship between osteoarthritis severity or symmetry and coronal concordance rates.Conclusions: Patients with knee osteoarthritis have poor side‐to‐side symmetry in lower limb coronal alignment. The concordance rate was 56% for the HKA classification, 39% for the CPAK classification and 11% for the phenotype classification. Therefore, the contralateral lower limb may not be a reliable reference for guiding coronal positioning and alignment in TKA surgery.Level of Evidence: Level III.


  • Open Access

    Standard Versus Dysplastic Inlay Implant for Patellofemoral Arthroplasty: Surgical Technique and Decision‐Making

    by Juan Ignacio Erquicia, David Martínez Jiménez, Albert Pons Riverola, Emiliano Cavalieri, Berta Gasol, Eric Camprubí, Jordi García Bonet, Joan Leal Blanquet

    Patellofemoral arthroplasty (PFA) has emerged as an alternative bone‐preserving surgical option for treating isolated symptomatic patellofemoral osteoarthritis that better replicates the natural knee kinematics compared with total knee arthroplasty. Achieving successful outcomes in PFA relies on meticulous patient selection, proper surgical technique, and appropriate implant choice and placement. Recent advancements in inlay trochlea implants, allowing for customized and anatomic joint line reconstruction with less bone resection, have demonstrated significant improvements in functional outcome scores and pain relief. This Technical Note aims to provide insights into the surgical technique of PFA with inlay implants, highlighting key considerations and potential challenges. It also assists surgeons in making informed decisions regarding the choice between standard and dysplastic inlay implants, while suggesting concurrent procedures to optimize tracking and overall outcomes. Technique Video: video See video under supplementary data.


  • Open Access

    Bone Cut Accuracy in Total Knee Arthroplasty: Do Conventional Cutting Guides Stay True to the Planned Coronal Orientation of the Components?

    by Joan Leal-Blanquet, Pedro Hinarejos, Elisenda Gimenez-Valero, Raul Torres-Claramunt, Juan Sánchez-Soler, Juan Erquicia, Sergi Gil-González, Angela Zumel-Marne, Juan Carlos Monllau

    Background: Total knee arthroplasty (TKA) has become the gold standard for the definitive treatment of knee osteoarthritis. One crucial aspect in the implantation of a TKA is the precise orientation of the femoral and tibial components. The main purpose of the present study is to assess, in patients undergoing total knee replacement, whether the difference between the planned angulation in the distal femoral cut and the angulation obtained in the postoperative radiological control is low enough to consider the conventional bone-cutting guides reliable. Methods: A retrospective study was designed with a consecutive series of patients who had undergone primary total knee arthroplasty using conventional instrumentation over one year. The authors analysed the main variable (bone cuts) while considering different variables (age, gender, surgeon, prosthesis, laterality, constraint, body mass index and alignment) to identify different patient patterns that justify the results in the main variable. Descriptive variables were analysed using the Mann–Whitney U and Kruskal–Wallis tests. Additionally, the correlation between continuous variables was explored in accordance with the Spearman correlation. Results: A total of 340 patients with a mean age of 75 ± 9.16 years were finally included in the present study. The mean absolute error of the main variable for the femoral coronal bone cut was 1.89° (SD 1.53). For the tibial coronal bone cut, it was 1.31° (SD 2.54). These values correspond to what remains after subtracting the radiological angulation obtained in the postoperative period from the planned intraoperative angulation of the distal femoral cut. No associations were observed between the main variable (the angulation of the proximal tibial cut and distal femoral cut) and the rest of variables for either the femur or tibia. Conclusion: A discrepancy between the planned angulation and the final radiological measure on the coronal plane of the femur and tibia using conventional cutting guides has been demonstrated. The degree of deviation is low enough that it probably does not affect clinical outcomes. Therefore, the use of conventional cutting guides will continue to be an appropriate tool to perform bone cuts in knee replacement surgery.


  • Open Access

    A lower starting point for the medial cut increases the posterior slope in opening‐wedge high tibial osteotomy: a cadaveric study

    by Juan Ignacio Erquicia, Sergi Gil‐Gonzalez, Maximiliano Ibañez, Joan Leal‐Blanquet, Andrés Combalia, Juan Carlos Monllau, Xavier Pelfort

    Purpose: The objective of this study was to evaluate the effects on the posterior tibial slope of different distances from the joint line to start the osteotomy and of varying the placement of the opening wedge in high tibial osteotomy.Starting the osteotomy more distally and an incorrect location for the tibial opening wedge were hypothesized to increase the posterior tibial slope.Methods: A cadaveric study was conducted using 12 knees divided into two groups based on the distance from the joint line to the start of the osteotomy: 3 and 4 cm. The preintervention posterior tibial slope was measured radiologically. Once the osteotomy was performed, the medial cortex of the tibia was divided into anteromedial, medial, and posteromedial thirds. A 10° opening wedge was sequentially placed in each third, and the effect on the posterior tibial slope was evaluated radiographically.Results: Significant changes were observed only in the 3‐cm group (p = 0.02) when the wedge was placed in the anteromedial zone. In contrast, in the 4‐cm group, significant differences were observed when the opening wedge was placed at both the medial (p = 0.04) and anteromedial (p = 0.012) zones.Conclusion: Correct control of the posterior tibial slope can be achieved by avoiding a low point when beginning the osteotomy and placing the opening wedge in the posteromedial third of the tibia when performing an opening‐wedge high tibial osteotomy.Level of evidence: Controlled laboratory study.


  • Open Access

    Internal Fixation of Osteochondritis Dissecans of the Knee Leads to Good Long-Term Outcomes and High Degree of Healing without Differences between Fixation Devices

    by Simone Perelli, Agustín Rubén Molina Romoli, Matías Costa-Paz, Juan Ignacio Erquicia, Pablo Eduardo Gelber, Juan Carlos Monllau

    The aim of the present study is to describe results at long-term follow-up of internal fixation of unstable Osteochondritis Dissecans (OCD) achieved with three different fixation devices in skeletally mature knees. A retrospective cohort study was performed at 5 to 19 years follow-up. Patient-reported questionnaires were collected at the final follow-up. Postoperative X-rays and MRIs were evaluated for healing of the lesion and articular degeneration. An arthroscopic second look was performed in 74.3% of the cases. Failures were reported as reintervention to address the osteochondral lesion or poor functional outcomes at the last follow-up. A total of 39 subjects with a median follow-up of 10.7 years were included. Herbert screws were used in 51.2% of the cases, bioabsorbable nails in 25.7% of the cases and cannulated screws in 23.1% of the cases. No differences were observed in terms of the clinical score (International Knee Documentation Committee (IKDC) p = 0.211; Lysholm p = 0.197), radiographic union (p = 0.102) or radiographic degeneration (p = 0.238) between the three different fixation devices. Arthroscopic second look found complete stability of the lesions in all 29 cases evaluated. The mean postoperative Lysholm score was 83 (range = 33–100) and IKDC score was 79 (range = 39–100). Radiographic union was seen in 74% of the cases. Lack of radiographic union was correlated with worst functional scores. A failure rate of 20.5% was found: four reinterventions were performed, and four patients had poor scores at last follow up. This study shows that internal fixation of condylar OCD in skeletally mature patients provides good long-term clinical results and a high degree of healing regardless of the dimensions of the lesion and type of fixation.


  • Open Access

    Biplane opening wedge high tibial osteotomy with a distal tuberosity osteotomy, radiological and clinical analysis with minimum follow‐up of 2 years

    by Juan Erquicia, Pablo Eduardo Gelber, Simone Perelli, Federico Ibañez, Maximiliano Ibañez, Xavier Pelfort, Juan Carlos Monllau

    Background: High tibial osteotomy is an established and helpful treatment for unicompatimental osteoarthritis associated with varus deformity. However, asupratubercle high tibial osteotomy leads to a decrease in patellar height making the technique not suitable in case of concomitant patella baja. Moreover, this kind of osteotomy can change in situ forces at patellofemoral joint and the lateral patellar tilt. With the aim to widen the indication of high tibial osteotomy was proposed a biplane opening wedge high tibial osteotomy with a distal tuberosity osteotomy (B‐OWHTO). This technique provide that the tibial tuberosity remains joined to the tibial metaphysis so as not to theoretically alter the patellar height. However, some Authors claim that BOWHTO could lead to an increase in tibial slope. The purpose of the present study was to assess the tibial slope, patella‐femoral changes and axial correction as well as functional outcomes following a B‐OWHTO.Methods: Patients operated on with a B‐OWHTO and a minimum 24 months of follow‐up were included. The mechanical alignment of the lower limb, patellar height, lateral patellar tilt and posterior tibial slope were calculated preoperatively, immediately after surgery and at the 24‐month follow‐up. The clinical results were evaluated using the Lysholm, Kujala and Hospital for Special Surgery knee scores. The possible postoperative development of patellofemoral pain or radiologic patellofemoral alteration was also evaluated.Results: Twenty‐three patients were included with a mean follow‐up of 33 months (range 27‐41). The mechanical alignment of the lower limb shifted from a mean 9.3º ± 2.5 varus preoperatively to a mean 0.2º ± 2.2 valgus postoperatively. No changes in patellar height, lateral patellar tilt or in the posterior tibial slope were observed. The mean Lysholm and HSS scores improved from 68.3 ± 9.1 and 64.2 ± 5.2 preoperatively to 93.2 ± 2.1 and 94.1 ± 3.6 at final follow‐up (p < 0.01). The mean Kujala score improved from 67.3 ± 9.8 to 86.4 ± 7.6 at final follow up (p < 0.01). No patients developed both radiological or clinical symptoms at patellofemoral joint.Conclusions: Open wedge high tibial osteotomy with a dihedral L‐cut distal and posterior to the tibial tubercle accurately corrected axial malalignment without any change at patella‐femoral joint or any modification to the posterior tibial slope while providing improved knee function at short‐term follow‐up. The radiographic as well as the clinical results support the use of this technique to treat medial compartment knee osteoarthritis and varus malalignment in young and middle‐aged patients with a normal‐to‐low patellar height.Level of evidence: Case series with no comparison group, Level IV.