Ellen E. Wilcox
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ellen E. Wilcox has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
George M. Daskalov
Department of Radiation Oncology, Saint Francis Hospital and Medical Center, Hartford, Connecticut
4 shared publicationsHolly Lincoln
Department of Radiation Oncology, Saint Francis Hospital and Medical Center, Hartford, Connecticut
2 shared publicationsBruce Kaplan
1 shared publicationBruce M. Kaplan
1 shared publicationEric VanRooy
1 shared publicationGeorge Daskalov
1 shared publication
Latest Publications
- 1 October 2011
- Published by Elsevier in Practical Radiation Oncology
- Vol. 1 (4) , 251-260
Stereotactic radiosurgery-radiotherapy: Should Monte Carlo treatment planning be used for all sites?
- 1 October 2011
- Published by Elsevier in Practical Radiation Oncology
- Vol. 1 (4) , 251-260
Stereotactic radiosurgery-radiotherapy: Should Monte Carlo treatment planning be used for all sites?
- 1 May 2010
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 77 (1) , 277-284
Comparison of Planned Dose Distributions Calculated by Monte Carlo and Ray-Trace Algorithms for the Treatment of Lung Tumors With CyberKnife: A Preliminary Study in 33 Patients
- 1 May 2010
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 77 (1) , 277-284
Comparison of Planned Dose Distributions Calculated by Monte Carlo and Ray-Trace Algorithms for the Treatment of Lung Tumors With CyberKnife: A Preliminary Study in 33 Patients
- 8 May 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part1) , 2259-2266
Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for photon fields smaller than produced by Cyberknife
For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high‐resolution measurement techniques. These relatively large areas of electronic disequilibrium make accurate dosimetry as well as dose calculation more difficult, and this is exacerbated in regions of tissue heterogeneity. Tissue heterogeneity was considered insignificant in the brain where stereotactic radiosurgery was first used. However, as this technique is expanded to the head and neck and other body sites, dose calculations need to account for dose perturbations in and beyond air cavities, lung, and bone. In a previous study we have evaluated EBT Gafchromic film (International Specialty Products, Wayne, NJ) for dosimetry and characterization of the Cyberknife radiation beams and found that it was comparable to other common detectors used for small photon beams in solid water equivalent phantoms. In the present work EBT film is used to measure dose in heterogeneous slab phantoms containing lung and bone equivalent materials for the radiation beams of diameter 7.5 to produced by the Cyberknife (Accuray, Sunnyvale, CA). These measurements are compared to calculations done with both the clinically utilized Raytrace algorithm as well as the newly developed Monte Carlo based algorithm available on the Cyberknife treatment planning system. Within the low density material both the measurements and Monte Carlo calculations correctly model the decrease in dose produced by a loss of electronic equilibrium, whereas the Raytrace algorithm incorrectly predicts an enhancement of dose in this region. Beyond the low density material an enhancement of dose is correctly calculated by both algorithms. Within the high density bone heterogeneity the EBT film measurements represent dose to unit density tissue in bone and agree with the Monte Carlo results when corrected to dose to unit density tissue in bone. We conclude that EBT film is an appropriate dosimeter for measuring dose in heterogeneous materials and these measurements agree with Monte Carlo calculations of dose as implemented in the Cyberknife treatment planning system.
- 8 May 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6Part1) , 2259-2266
Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for photon fields smaller than produced by Cyberknife
For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high‐resolution measurement techniques. These relatively large areas of electronic disequilibrium make accurate dosimetry as well as dose calculation more difficult, and this is exacerbated in regions of tissue heterogeneity. Tissue heterogeneity was considered insignificant in the brain where stereotactic radiosurgery was first used. However, as this technique is expanded to the head and neck and other body sites, dose calculations need to account for dose perturbations in and beyond air cavities, lung, and bone. In a previous study we have evaluated EBT Gafchromic film (International Specialty Products, Wayne, NJ) for dosimetry and characterization of the Cyberknife radiation beams and found that it was comparable to other common detectors used for small photon beams in solid water equivalent phantoms. In the present work EBT film is used to measure dose in heterogeneous slab phantoms containing lung and bone equivalent materials for the radiation beams of diameter 7.5 to produced by the Cyberknife (Accuray, Sunnyvale, CA). These measurements are compared to calculations done with both the clinically utilized Raytrace algorithm as well as the newly developed Monte Carlo based algorithm available on the Cyberknife treatment planning system. Within the low density material both the measurements and Monte Carlo calculations correctly model the decrease in dose produced by a loss of electronic equilibrium, whereas the Raytrace algorithm incorrectly predicts an enhancement of dose in this region. Beyond the low density material an enhancement of dose is correctly calculated by both algorithms. Within the high density bone heterogeneity the EBT film measurements represent dose to unit density tissue in bone and agree with the Monte Carlo results when corrected to dose to unit density tissue in bone. We conclude that EBT film is an appropriate dosimeter for measuring dose in heterogeneous materials and these measurements agree with Monte Carlo calculations of dose as implemented in the Cyberknife treatment planning system.
- 12 December 2006
- Published by Wiley in Medical Physics
- Vol. 34 (1) , 41-48
Comparison of the Epson Expression 1680 flatbed and the Vidar VXR‐16 Dosimetry PRO™ film scanners for use in IMRT dosimetry using Gafchromic and radiographic film
Intensity‐modulated radiotherapy (IMRT) treatment plan verification is often done using Kodak EDR2 film and a Vidar Dosimetry PRO™ film digitizer. However, since many hospitals are moving towards a filmless environment, access to a film processor may not be available. Therefore, we have investigated a newly available EBT film for IMRT dosimetry. Planar IMRT dose distributions are delivered to both EBT and EDR2 film and scanned with the Vidar VXR‐16 as well as an Epson Expression 1680 flatbed scanner. The measured dose distributions are then compared to those calculated with a Pinnacle treatment planning system. The IMRT treatments consisted of 7–9 beams for treatment of prostate, head and neck, and a few other sites. The films were analyzed using FilmQA™ (3cognition LLC) software. Comparisons between measured and calculated dose distributions are reported as dose difference (DD) (pixels within ), distance to agreement (DTA) , as well as gamma values (, ). Using EDR2 with the Vidar scanner is an established technique and agreement between calculated and measured dose distributions was better than 90% in all indices (DD, DTA, and ). However, agreement with calculations deteriorated reaching the lower 80% for EBT film scans with the Vidar scanner in logarithmic mode. The EBT Vidar scans obtained in linear mode showed an improved agreement to the upper 80% range, but artifacts were still observed across the scan. These artifacts were very distinct in all EBT scans and can be attributed to the way the film is transported through the scanner. In the Epson scanner both films are rigidly immobilized and the light source scans over the film. It was found that the Epson scanner performed equally well with both types of film giving agreement to better than 90% in all indices.
- 12 December 2006
- Published by Wiley in Medical Physics
- Vol. 34 (1) , 41-48
Comparison of the Epson Expression 1680 flatbed and the Vidar VXR‐16 Dosimetry PRO™ film scanners for use in IMRT dosimetry using Gafchromic and radiographic film
Intensity‐modulated radiotherapy (IMRT) treatment plan verification is often done using Kodak EDR2 film and a Vidar Dosimetry PRO™ film digitizer. However, since many hospitals are moving towards a filmless environment, access to a film processor may not be available. Therefore, we have investigated a newly available EBT film for IMRT dosimetry. Planar IMRT dose distributions are delivered to both EBT and EDR2 film and scanned with the Vidar VXR‐16 as well as an Epson Expression 1680 flatbed scanner. The measured dose distributions are then compared to those calculated with a Pinnacle treatment planning system. The IMRT treatments consisted of 7–9 beams for treatment of prostate, head and neck, and a few other sites. The films were analyzed using FilmQA™ (3cognition LLC) software. Comparisons between measured and calculated dose distributions are reported as dose difference (DD) (pixels within ), distance to agreement (DTA) , as well as gamma values (, ). Using EDR2 with the Vidar scanner is an established technique and agreement between calculated and measured dose distributions was better than 90% in all indices (DD, DTA, and ). However, agreement with calculations deteriorated reaching the lower 80% for EBT film scans with the Vidar scanner in logarithmic mode. The EBT Vidar scans obtained in linear mode showed an improved agreement to the upper 80% range, but artifacts were still observed across the scan. These artifacts were very distinct in all EBT scans and can be attributed to the way the film is transported through the scanner. In the Epson scanner both films are rigidly immobilized and the light source scans over the film. It was found that the Epson scanner performed equally well with both types of film giving agreement to better than 90% in all indices.